background image

111921-01D

For more information, visit www.desatech.com

For more information, visit www.desatech.com

5

5

CLEARANCES

Minimum clearances to combustibles for the fireplace are as follows:
Back, and sides

0"/mm

Perpendicular walls

6" (152mm)

Floor

0"/mm

Ceiling to louver opening 42" (1067mm)
Front

36" (914mm)

Top of Standoffs

0"/mm

Vent

(See venting instructions for
specific venting clearances.)

Combustible material with a maximum thickness of 5/8" may be
flush with the top front of fireplace .

FRAMING AND FINISHING

Figure 4 shows typical framing of this fireplace. Figure 5 shows
framing for corner installation. All minimum clearances must be met.

For available accessories for this fireplace, see 

Accessories

 on page

36. If you are using a separate combustible mantel piece, refer to
Figure 6 for proper installation height. You can install noncombus-
tible mantels at any height above the fireplace.

Note:

 Noncombustible mantels may discolor!

PRE-INSTALLATION
PREPARATION

Continued

NOTICE: This fireplace is intended for use as supple-
mental heat. Use this fireplace along with your pri-
mary heating system. Do not install this fireplace as
your primary heat source. If you have a central heat-
ing system, you may run system’s circulating blower
while using fireplace. This will help circulate the heat
throughout the house. In the event of a power outage,
you can use this fireplace as a heat source.

Figure 4 - Framing Clearances for Installation Against an Exterior
Wall

C

B

A

D

E

F

G

Top of Louver Opening

3

2

1

4

5

6

7

Wall

A

B

E

F

G

H

D

C

Nailing Tabs

Figure 5 - Framing Clearances for Corner Installation

Ref. Mantel Depth Ref. Mantel from Top

of Louver Opening

  1

14" (356mm)  A

16" (406mm)

  2

12" (305mm)  B

14" (356mm)

  3

10" (254mm)  C

12" (305mm)

  4

8" (203mm)

 D

10" (254mm)

  5

6" (152mm)

 E

8" (203mm)

  6

4" (101mm)

 F

6" (152mm)

  7

2" (51mm)

 G

4" (101mm)

Figure 6 - Clearances for Combustible Mantels

PRE-INSTALLATION PREPARATION

Clearances

Framing and Finishing

41

5

/

8

"

21

5

/

8

"

13

1

/

2

"

58

1

/

2

"

16

3

/

4

"

48"

48

1

/

4

"

81

1

/

2

"

40

1

/

8

"

48

1

/

4

"

25 

5

/

8

"

Содержание K42N SERIES

Страница 1: ...te or local codes WARNING If the information in this manual is not followed exactly a fire or explosion may result caus ing property damage personal injury or loss of life FOR YOUR SAFETY Donotstoreor...

Страница 2: ...g system Itbringsinfreshairforcombustionthroughtheouterpipeand combustion gases are exhausted through the inner pipe If the glass door assembly and venting pipe are not properly seated connected and s...

Страница 3: ...12 Do not use this fireplace to cook food or burn paper or other objects 13 Do not use any solid fuels wood coal paper cardboard etc in this fireplace Use only the gas type indicated on fireplace nam...

Страница 4: ...he location of your fireplace follow these rules Do not connect this fireplace venting to a chimney flue serving a separate solid fuel burning fireplace or appliance Due to high temperatures do not lo...

Страница 5: ...ote Noncombustible mantels may discolor PRE INSTALLATION PREPARATION Continued NOTICE This fireplace is intended for use as supple mental heat Use this fireplace along with your pri mary heating syste...

Страница 6: ...nlet 72 inches 182 9cm minimum L clearance above paved side walk or a paved driveway located on public property 84 inches 213 3cm minimum M clearance under veranda porch deck 12 inches 30 5cm minimum...

Страница 7: ...lls and firestops when penetrating ceilings or attic spaces Install horizontal venting with a 1 4 rise for every 12 of run toward the termination VENTING INSTALLATION INSTRUCTIONS NOTICE Read these in...

Страница 8: ...sections together and twist one section clockwise approxi mately one quarter turn until the sections are fully locked see Figure 8 Note Horizontal runs of vent must be sup ported every three feet Use...

Страница 9: ...ly non hardening mastic around outside edge of stand off Position the standoff cap assembly in the center of the 10 3 4 square hole and attach to exterior wall with wood screws provided see Figure 11...

Страница 10: ...gmust have a 1 4 rise for every 12 of run toward the termination Figure 13 Typical Horizontal Termination Cap Mounting with Additional Siding Standoff Installed Siding Standoff Screws High Wind Termin...

Страница 11: ...ring a vertical rise on building exterior Any installation using snorkel termination to achieve one foot above ground Snorkel terminations are available for installations requiring a vertical rise on...

Страница 12: ...ce Venting with Two 90 Elbows Vertical V Horizontal H1 Horizontal H1 Horizontal H2 5 min 2 max 6 max 6 min 4 max 12 max 7 min 6 max 18 max 8 min 8 max 20 max 20 max 8 max 20 max Figure 17 Horizontal T...

Страница 13: ...om install firestop above framed hole 2 Assemble the desired lengths of pipe and elbows necessary to reach from the fireplace flue up through the firestop Be sure all pipe and elbow connections are fu...

Страница 14: ...Elbow Vertical V Horizontal H 5 min 2 max 6 min 4 max 7 min 6 max 8 min 8 max 20 max 8 max Figure 22 Vertical Venting Configuration Using One 90 Elbow Vertical Round High Wind Termination Shown Note...

Страница 15: ...ENTINGKITSANDCOMPONENTS DESA 5 8 Pipe Vent Kits Number Description P58 6 6 Section Double Wall Pipe Galvanized P58 12 12 Section Double Wall Pipe Galvanized P58 24 24 Section Double Wall Pipe Galvaniz...

Страница 16: ...Control Shaft Locknut Control Knob Switch Bracket Blower Plug In Side View Lower Firebox Cavity Blower Location FIREPLACE INSTALLATION Check Gas Type Installing Optional Blower Accessories Duplex Outl...

Страница 17: ...each and make all connections DO NOT trim excessive length away Just enable enough to make all connections securely 3 Place the blower against the lower rear wall of the firebox outer wrapperwiththeex...

Страница 18: ...ulator not supplied Install the external regulator between the fireplace and propane LP supply Figure 30 External Regulator with Vent Pointing Down Propane LP Only Propane LP Supply Tank External Regu...

Страница 19: ...within reach for cleaning Install in piping system between fuel supply and fireplace Locate sediment trap drip leg where trapped matter is not likely to freeze A sediment trap traps moisture and conta...

Страница 20: ...Connections 1 Open equipment shutoff valve see Figure 33 2 Openpropane LPsupplytankvalveforpropane LPfireplaceor main gas valve located on or near gas meter for natural gas fireplace 3 Make sure contr...

Страница 21: ...ring latches towards the center of the appliance until they are disengaged from the locating holes see Figure 41 Repeat for bottom spring latches and pull the louvers outward To install or replace ite...

Страница 22: ...re 43 7 Install the right brick panel using the same method described in step 6 8 Replace deflector shield using screws removed in step 4 9 Follow instructions to install logs lava rock and ember mate...

Страница 23: ...Each log is marked with a number These numbers will help you identify the log when installing It is very important to install these logs exactly as instructed Do not modify logs Only use logs supplie...

Страница 24: ...rol knob counterclockwise to PILOT 8 Push in gas control knob all the way and hold Immedi ately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears Continue to hold...

Страница 25: ...eit Centigrademodedisplay carefullypressthe C Fmode button with the end of a paper clip or similar blunt object Manual Mode 1 Press the POWER and LOCK buttons together to turn on the hand held remote...

Страница 26: ...the heater to the OFF position WARNING Donotconnectthethermostattoapower source Electrical shock and or a fire hazard will occur INSPECTING BURNERS Check pilot flame pattern and burner flame patterns...

Страница 27: ...used CLEANING AND MAINTENANCE CAUTION Wear gloves and safety glasses while handling or removing broken glass Do not remove if glass is hot Keep children and pets away from glass WARNING Donotoperatef...

Страница 28: ...y or partially clogged pilot 5 Thermocouple connection loose at con trol valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any me...

Страница 29: ...te burner until air is removed from line Have gas line checked by local pro pane LP or natural gas company 3 Clean burner see Cleaning and Mainte nance page 27 or replace burner orifice 1 Adjust the l...

Страница 30: ...r holes at burner inlet blocked 3 Burner flame holes blocked OBSERVED PROBLEM Fireplace produces unwanted odors Fireplace shuts off in use Gas odor even when control knob is in OFF position Gas odor d...

Страница 31: ...RVICE You may have further questions about installation operation or troubleshooting If so contact DESA s Customer Service Depart mentat1 866 672 6040 Whencalling pleasehaveyourmodeland serial numbers...

Страница 32: ...ore information visit www desatech com 32 6 7 20 17 18 13 2 12 19 8 1 4 11 9 14 3 16 5 10 2 10 1 10 8 10 5 10 4 10 3 10 7 10 9 15 10 6 21 ILLUSTRATED PARTS BREAKDOWN V K42N V K42NH V K42P V K42PH ILLU...

Страница 33: ...dels Only 1 4 108331 01 Top Louver Assembly 1 5 108331 02 Bottom Louver Assembly 1 6 Fireplace Top 1 7 Fireplace Top Insulation 1 8 Fireplace Surround 1 9 109082 01 Heat Shield 1 10 111925 01 Log Set...

Страница 34: ...For more information visit www desatech com 34 ILLUSTRATED PARTS BREAKDOWN BURNER ASSEMBLY FOR MODELS V K42N V K42NH V K42P V K42PH ILLUSTRATED PARTS BREAKDOWN V K42N V K42NH V K42P V K42PH 1 2 3 4 5...

Страница 35: ...r 1 2 111311 02 Grate Base 1 3 111313 02 Burner Base Bottom 1 4 26808 Valve Bracket 1 5 11107 Screw 10 32 x 1 4 PPH Zinc 4 6 111310 02 Firebox Bottom 1 7 11102 Screw 8 32 x 3 8 PPH Zinc 2 8 111912 01...

Страница 36: ...Not Shown LT42B Rolled Louver Trim Kit Brushed Brass LT42P Rolled Louver Trim Kit Platinum LT42PB Rolled Louver Trim Kit Polished Brass DEFLECTION HOOD Not Shown HD42 Hood Black 2 Brow PERIMETER TRIM...

Страница 37: ...School Completed College Completed Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 9...

Страница 38: ...111921 01D For more information visit www desatech com For more information visit www desatech com 38 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Страница 39: ...___________________________________________________________ _______________________________________________________________________________________________ ____________________________________________...

Страница 40: ...ansportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE...

Отзывы: