 WARNING: Do not recess vent termination into

any wall. This will cause a fire hazard.

6.

Noncombustible Exterior Wall:

 

Position the horizontal vent

cap in the center of the 8 

1

/

2

" round hole and attach to the exte-

rior wall with four wood screws provided. Before attaching
the vent cap to exterior wall, run a bead of non-hardening mastic
(pliable sealant) around the outside edges to make a seal be-
tween it and the outside wall. 

Note:

 The four wood screws

provided should be replaced with appropriate fasteners for
stucco, brick, concrete, or other types of sidings.

Combustible Exterior Wall:

 For vinyl siding, stucco, or wood

exteriors, a siding standoff may be installed between the vent
cap and exterior wall. The siding standoff prevents excessive
heat from damaging the siding materials. Siding material must
be cut to accommodate standoff. Bolt the vent cap to the stand-
off. Apply non-hardening mastic around outside edge of stand-
off. Position the standoff/cap assembly in the center of the
10 

3

/

4

" square hole and attach to exterior wall with wood

screws provided (see Figure 11). The siding standoff must sit
flush against the exterior fascia material.

7.

Combustible Exterior Wall Only:

 Slide the wall firestop over

the vent pipe before connecting horizontal run to vent cap (see
Figure 12).

8.

Carefully move fireplace, with vent assembly attached, toward
wall and insert vent pipe into horizontal termination. The pipe
overlap should be a minimum of 1

1

/

4

". Fasten all vent pipe

connections (except vent cap) with screws provided.

VENTING INSTALLATION
INSTRUCTIONS

Continued

VENTING INSTALLATION INSTRUCTIONS

Installation Planning (Cont.)

Figure 10  - Installing Horizontal Vent Cap (Noncombustible
Exterior)

Apply Mastic to
All Four Sides

Figure 11 - Installing Siding Standoff (Combustible Exterior)

Vent Cap
(Horizontal
Termination)

Interior Wall
Surface

Wall
Firestop

Horizontal
Vent Pipe

Figure 12 - Connecting Vent Cap with Horizontal Vent Pipe

Screw

Cut Siding Away
to Fit Standoff

Wood Screw

Screws

Standoff

Vent Cap

Apply Mastic
to All Four Sides

Wood Screw

Vent Cap

Содержание K42N SERIES

Страница 1: ...te or local codes WARNING If the information in this manual is not followed exactly a fire or explosion may result caus ing property damage personal injury or loss of life FOR YOUR SAFETY Donotstoreor...

Страница 2: ...g system Itbringsinfreshairforcombustionthroughtheouterpipeand combustion gases are exhausted through the inner pipe If the glass door assembly and venting pipe are not properly seated connected and s...

Страница 3: ...12 Do not use this fireplace to cook food or burn paper or other objects 13 Do not use any solid fuels wood coal paper cardboard etc in this fireplace Use only the gas type indicated on fireplace nam...

Страница 4: ...he location of your fireplace follow these rules Do not connect this fireplace venting to a chimney flue serving a separate solid fuel burning fireplace or appliance Due to high temperatures do not lo...

Страница 5: ...ote Noncombustible mantels may discolor PRE INSTALLATION PREPARATION Continued NOTICE This fireplace is intended for use as supple mental heat Use this fireplace along with your pri mary heating syste...

Страница 6: ...nlet 72 inches 182 9cm minimum L clearance above paved side walk or a paved driveway located on public property 84 inches 213 3cm minimum M clearance under veranda porch deck 12 inches 30 5cm minimum...

Страница 7: ...lls and firestops when penetrating ceilings or attic spaces Install horizontal venting with a 1 4 rise for every 12 of run toward the termination VENTING INSTALLATION INSTRUCTIONS NOTICE Read these in...

Страница 8: ...sections together and twist one section clockwise approxi mately one quarter turn until the sections are fully locked see Figure 8 Note Horizontal runs of vent must be sup ported every three feet Use...

Страница 9: ...ly non hardening mastic around outside edge of stand off Position the standoff cap assembly in the center of the 10 3 4 square hole and attach to exterior wall with wood screws provided see Figure 11...

Страница 10: ...gmust have a 1 4 rise for every 12 of run toward the termination Figure 13 Typical Horizontal Termination Cap Mounting with Additional Siding Standoff Installed Siding Standoff Screws High Wind Termin...

Страница 11: ...ring a vertical rise on building exterior Any installation using snorkel termination to achieve one foot above ground Snorkel terminations are available for installations requiring a vertical rise on...

Страница 12: ...ce Venting with Two 90 Elbows Vertical V Horizontal H1 Horizontal H1 Horizontal H2 5 min 2 max 6 max 6 min 4 max 12 max 7 min 6 max 18 max 8 min 8 max 20 max 20 max 8 max 20 max Figure 17 Horizontal T...

Страница 13: ...om install firestop above framed hole 2 Assemble the desired lengths of pipe and elbows necessary to reach from the fireplace flue up through the firestop Be sure all pipe and elbow connections are fu...

Страница 14: ...Elbow Vertical V Horizontal H 5 min 2 max 6 min 4 max 7 min 6 max 8 min 8 max 20 max 8 max Figure 22 Vertical Venting Configuration Using One 90 Elbow Vertical Round High Wind Termination Shown Note...

Страница 15: ...ENTINGKITSANDCOMPONENTS DESA 5 8 Pipe Vent Kits Number Description P58 6 6 Section Double Wall Pipe Galvanized P58 12 12 Section Double Wall Pipe Galvanized P58 24 24 Section Double Wall Pipe Galvaniz...

Страница 16: ...Control Shaft Locknut Control Knob Switch Bracket Blower Plug In Side View Lower Firebox Cavity Blower Location FIREPLACE INSTALLATION Check Gas Type Installing Optional Blower Accessories Duplex Outl...

Страница 17: ...each and make all connections DO NOT trim excessive length away Just enable enough to make all connections securely 3 Place the blower against the lower rear wall of the firebox outer wrapperwiththeex...

Страница 18: ...ulator not supplied Install the external regulator between the fireplace and propane LP supply Figure 30 External Regulator with Vent Pointing Down Propane LP Only Propane LP Supply Tank External Regu...

Страница 19: ...within reach for cleaning Install in piping system between fuel supply and fireplace Locate sediment trap drip leg where trapped matter is not likely to freeze A sediment trap traps moisture and conta...

Страница 20: ...Connections 1 Open equipment shutoff valve see Figure 33 2 Openpropane LPsupplytankvalveforpropane LPfireplaceor main gas valve located on or near gas meter for natural gas fireplace 3 Make sure contr...

Страница 21: ...ring latches towards the center of the appliance until they are disengaged from the locating holes see Figure 41 Repeat for bottom spring latches and pull the louvers outward To install or replace ite...

Страница 22: ...re 43 7 Install the right brick panel using the same method described in step 6 8 Replace deflector shield using screws removed in step 4 9 Follow instructions to install logs lava rock and ember mate...

Страница 23: ...Each log is marked with a number These numbers will help you identify the log when installing It is very important to install these logs exactly as instructed Do not modify logs Only use logs supplie...

Страница 24: ...rol knob counterclockwise to PILOT 8 Push in gas control knob all the way and hold Immedi ately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears Continue to hold...

Страница 25: ...eit Centigrademodedisplay carefullypressthe C Fmode button with the end of a paper clip or similar blunt object Manual Mode 1 Press the POWER and LOCK buttons together to turn on the hand held remote...

Страница 26: ...the heater to the OFF position WARNING Donotconnectthethermostattoapower source Electrical shock and or a fire hazard will occur INSPECTING BURNERS Check pilot flame pattern and burner flame patterns...

Страница 27: ...used CLEANING AND MAINTENANCE CAUTION Wear gloves and safety glasses while handling or removing broken glass Do not remove if glass is hot Keep children and pets away from glass WARNING Donotoperatef...

Страница 28: ...y or partially clogged pilot 5 Thermocouple connection loose at con trol valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any me...

Страница 29: ...te burner until air is removed from line Have gas line checked by local pro pane LP or natural gas company 3 Clean burner see Cleaning and Mainte nance page 27 or replace burner orifice 1 Adjust the l...

Страница 30: ...r holes at burner inlet blocked 3 Burner flame holes blocked OBSERVED PROBLEM Fireplace produces unwanted odors Fireplace shuts off in use Gas odor even when control knob is in OFF position Gas odor d...

Страница 31: ...RVICE You may have further questions about installation operation or troubleshooting If so contact DESA s Customer Service Depart mentat1 866 672 6040 Whencalling pleasehaveyourmodeland serial numbers...

Страница 32: ...ore information visit www desatech com 32 6 7 20 17 18 13 2 12 19 8 1 4 11 9 14 3 16 5 10 2 10 1 10 8 10 5 10 4 10 3 10 7 10 9 15 10 6 21 ILLUSTRATED PARTS BREAKDOWN V K42N V K42NH V K42P V K42PH ILLU...

Страница 33: ...dels Only 1 4 108331 01 Top Louver Assembly 1 5 108331 02 Bottom Louver Assembly 1 6 Fireplace Top 1 7 Fireplace Top Insulation 1 8 Fireplace Surround 1 9 109082 01 Heat Shield 1 10 111925 01 Log Set...

Страница 34: ...For more information visit www desatech com 34 ILLUSTRATED PARTS BREAKDOWN BURNER ASSEMBLY FOR MODELS V K42N V K42NH V K42P V K42PH ILLUSTRATED PARTS BREAKDOWN V K42N V K42NH V K42P V K42PH 1 2 3 4 5...

Страница 35: ...r 1 2 111311 02 Grate Base 1 3 111313 02 Burner Base Bottom 1 4 26808 Valve Bracket 1 5 11107 Screw 10 32 x 1 4 PPH Zinc 4 6 111310 02 Firebox Bottom 1 7 11102 Screw 8 32 x 3 8 PPH Zinc 2 8 111912 01...

Страница 36: ...Not Shown LT42B Rolled Louver Trim Kit Brushed Brass LT42P Rolled Louver Trim Kit Platinum LT42PB Rolled Louver Trim Kit Polished Brass DEFLECTION HOOD Not Shown HD42 Hood Black 2 Brow PERIMETER TRIM...

Страница 37: ...School Completed College Completed Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 9...

Страница 38: ...111921 01D For more information visit www desatech com For more information visit www desatech com 38 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Страница 39: ...___________________________________________________________ _______________________________________________________________________________________________ ____________________________________________...

Страница 40: ...ansportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE...

Отзывы: