INSTALLATION
Continued
MANTEL CLEARANCES
In addition to meeting noncombustible mate-
rial clearances, you must also meet required
clearances between fireplace opening and
mantel shelf. If you do not meet the clearances
listed below, you will need a hood.
Determining Minimum Mantel Clearance
If you meet minimum clearance between
mantel shelf and top of fireplace opening, a
hood is not required (see Figure 6).
Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace
Figure 6 - Minimum Mantel Clearances Without Using Hood
Minimum
Noncombustible
Material
Minimum
Noncombustible
Material Height
Distances to
Underside of
Mantel
Top of
Fireplace
Opening
Underside
of Mantel
Shelf
Mantel Shelf
12"
(A)
18"
20"
22"
24"
All minimum
distances are
in inches
Log Set
All
Models
2
1/2
"
6"
8"
10"
Noncombustible
Requirements for
Material Distance (A) Safe Installation
12" or more
Noncombustible material okay.
Between 8"
Install fireplace hood and 12" accessory
(GA6050, GA6052 or GA6053, see
Accessories
, page 33).
Less than 8"
Noncombustible material must be
extended to at least 8". See
Between
8" and 12"
, above. If you cannot extend
material, you must operate heater with
flue damper open.