Equipment
Shutoff Valve
Propane/LP
Supply
Tank
Control Valve
Location
Figure 17 - Checking Gas Joints
(Natural Gas Only)
Gas Meter
Equipment
Shutoff Valve
Figure 16 - Checking Gas Joints
(Propane/LP Gas Only)
INSTALLATION
Continued
Control Valve
Location
INSTALLING LOGS
WARNING: Failure to posi
-
tion the parts in accordance
with these diagrams or failure
to use only parts specifically
approved with this heater may
result in property damage or
personal injury.
CAUTION: After installa-
tion and periodically thereafter,
check to ensure that no flame
comes in contact with any log.
With the heater set to High, check
to see if flames contact any log. If
so, reposition logs according to
the log installation instructions
in this manual. Flames contact
-
ing logs will create soot.
It is very important to install the logs exactly
as instructed. Do not modify logs. Only use
logs supplied with heater. Before installing
logs, make sure log alignment screws are in
place and straight.
1. Place log #1 (ember bed) onto base over
alignment screws to left of front burner
and behind middle burner. Log #1 will sit
on top of front and middle burners (see
Figure 18).
2. Place log #2 to the right of log #1. Log #2 will
wrap around right end of rear burner and sit
on log alignment screw (see Figure 19).
3. Place log #3 on left side of base and onto
alignment screw to right of rear burner
(see Figure 19). Log #3 will wrap around
left end of rear burner.
Figure 18 - Installing Log #1 (Ember Bed)
Log #1
Log #5 will seat
in this location
Figure 19 - Installing Log #2 (Right) and
Log #3 (Left)
Log #3
Log #1
Log #2