![Deprag SZG Controller 6 Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/deprag/szg-controller-6/szg-controller-6_operating-manual_2485171033.webp)
SZG CONTROLLER 6 - ENGLISH
33
NOTE:
There is no password protection in the factory set status. If you have set up a password and
restore factory settings you will have to reset your password.
11.5
Load control (Strain gauge)
Bild 19: Strain gauge / sensor (DMS) on vibratory bowl
The feeder series 6 uses strain gauge to measure the current vibration of the vibratory bowl and calculates
the control required. The resulting vibration is not influenced by the fill level of the bowl.
In the menu section LOAD CONTROL the vibration intensity of the vibratory drive can be set. Press the
button
to increase vibration and press the button
to decrease vibration. The load control has 50
possible steps.
11.6
Soft start
The feeder controller for series 6 has a time-optimised soft start. In the menu section SOFT START the soft
start can be switched on or off.
11.7
Operation without strain gauge
The feeder series 6 is usually operated with strain gauge. If the vibratory bowl control by the strain gauge is
not working properly then the controller can be set to operate without strain gauge (emergency operation).
A linear conveyer works as standard without strain gauge. Set up via menu section OP W/O STR GAUGE
→
SETTING.
In the menu section OP W/O STR GAUGE first set ACTIVATE to “yes” in the sub section. Next set the load
control for the bowl in sub section SETTING. Load control has 50 steps.
NOTE:
During operation without strain gauge the vibratory bowl will vibrate more strongly or weakly
depending on fill level of the bowl.