21
11.1.1 DMS Settings
When using the DMS measuring platform from DEPRAG choose the option “DMS-
e.
DEPRAG” on the left-hand sid
Picture 5:
Settings for DMS sensor
Next set the correct type of DMS. The measurement range of the chosen type is
displayed in the lower part of the main program (see
Measurement Process
). The
calibration value of the measurement sensor is set in the field C-Value. The value can
either be entered directly or changed by using the arrow keys.
When using a different manufacturer’s DMS measuring platform choose “DMS-other”.
Picture 6:
Settings for a different manufacturer’s DMS sensor
Next enter the nominal torque and the corresponding unit as well as the sensitivity in
mV/V. The measurement range of the chosen type is displayed in lower part of the main
program (see
Measurement Process
). The calibration value of the measurement sensor
e. The value can either be entered directly or changed by using
Choose the option “Piezo-DEPRAG “on the left-hand side.
is set in the field C-Valu
the arrow keys.
1.1.2 Piezo Settings
1
Picture 7:
Settings for piezo sensor