
- 36 -
8. Checking the bolts and nuts
• Check whether bolts and nuts are securely tightened or not especially for the air cleaner,
muffler mounting section. If loose, retighten them.
3-4-2 Instruction for Fuel Device
(1) Setting Procedure for Separate Tank
Where fuel source is a separate tank placed outside the machine, disconnect the tank
connection plug and change the connection as shown in the Fig.9.
(2) Caution on Setting
①
For the piping, use oil-resistant hose of 9.6 mm or more internal diameter. Under Cold environ- ment,
use the hose of lager diameter.
②
Install the separate fuel tank as near the machine as possible.
③
Set the suction end in the separate tank at the position of 15 to 20 mm upper than the bottom
level (as shown in Section-A of the Fig.9), so that water or sediment may not come into the
suction.
④
While feeding the fuel into the separate tank, do not allow water or dust to come in.
Fig.
9
Содержание DCA-600P
Страница 55: ...53 6 TROUBLESHOOTING...