- 30 -
CAUTION
• Avoid overloading the generator.
The generator is provided with circuit breakers for overload protection. When a circuit breaker
has tripped, reduce the concerned load before re-starting.
• Do not connect the output voltage from the machine to facilities wired to the commercial power
supply.
• Before connecting a load, turn off a corresponding circuit breaker and make sure that the
frequency, voltage and power factor of the load to connect match the generator ratings.
• Before checking the machine, stop the engine and wait for at least 10 minutes so that it will cool
down completely. If done while running or immediately after shutdown, you might get burnt or
injured.
• Do not operate the machine beyond the range given in the main specification table.
• In room or environment where the sound pressure level reaches or exceeds 90 dB (A), use ear
protectors.
• During the operation, keep all panels closed.
• Periodically check that:
1. All guards are in place and securely fastened.
2. All hoses and/or pipes are in good condition, not bent and not rubbing.
3. There are no leaks of fuel, oil, cooling water, etc.
4. All fasteners are tight.
5. All electrical leads are secure and in good order.
6. The electrical cables are not damaged.
[ NOTES ]
: • Do not remove any of, or tamper with, the sound-damping material.
• Whenever an abnormal condition arises, e.g., excessive vibration, noise, odour,
etc., switch the circuit breakers to OFF and stop the engine. Correct the faulty
condition before re-starting.
Содержание DCA-600P
Страница 55: ...53 6 TROUBLESHOOTING...