background image

ENGLISH • 2

Table of Contents

Section

Section Title

Page

Number

Description of Contents

Number

1

Indications ................................................................................................................................................................................. 3

2

Contraindications and Warnings/Adverse Reactions ........................................................................................................ 3

2.1 Contraindications
2.2 Warnings

3

Precautions ................................................................................................................................................................................. 3

3.1 Precautions for All Systems
3.2 Precautions for Ultrasonic Prophylaxis Procedures

4

Infection  Control ...................................................................................................................................................................... 4

4.1 Infection Control Information Reference Card
4.2 General Infection Control Recommendations
4.3 Water Supply Recommendations

5

Installation  Instructions ...................................................................................................................................................... 4-5

5.1 General Information
5.2 Water Line Requirements
5.3 Electrical Requirements
5.4 Unpacking the System
5.5 Power Cord/Power Connection
5.6 Foot Control Cable Assembly Connection
5.7 Water Supply Line Connection

6

SPS

 Ultrasonic Scaler Description .................................................................................................................................... 6-7

6.1 System Controls
6.2 Handpiece
6.3 Cavitron

®

 30K

 Ultrasonic Inserts

6.4 Foot Control Information & Operation

7

Accessories .................................................................................................................................................................................. 7

8

Techniques for Use ................................................................................................................................................................... 8

8.1 Patient Positioning
8.2 Performing Ultrasonic Scaling Procedures
8.3 Patient Comfort Considerations

9

System Care ........................................................................................................................................................................... 8–9

9.1 Daily Maintenance — Start-Up Procedures, Between Patients, Shut-Down Procedures
9.2 Weekly Maintenance
9.3 Water Filter Maintenance

10

Troubleshooting ....................................................................................................................................................................... 9

10.1 Troubleshooting Guide
10.2 Technical Support and Repairs

11

Specifications ............................................................................................................................................................................ 10

12

Classification ............................................................................................................................................................................ 10

Содержание Cavitron SPS

Страница 1: ...ically controls the tip stroke over different working conditions The Cavitron SPS scaler produces 30 000 microscopically small strokes per second at the insert s working tip This combined with acousti...

Страница 2: ...s 5 3 Electrical Requirements 5 4 Unpacking the System 5 5 Power Cord Power Connection 5 6 Foot Control Cable Assembly Connection 5 7 Water Supply Line Connection 6 SPS Ultrasonic Scaler Description 6...

Страница 3: ...rocedures 2 2 Warnings Persons fitted with cardiac pacemakers have been cautioned that some types of electronic equipment might interfere with the operation of a pacemaker Although no instance of pace...

Страница 4: ...ther areas contact your local DENTSPLY representative 4 2 GeneralInfectionControl Recommendations As with all dental procedures use standard personal protection equipment i e wear face mask eyewear or...

Страница 5: ...into an approved outlet Section 5 Installation Instructions cont d 5 6 Foot ControlCable Assembly Connection Align the Foot Control plug with the receptacle on the back of the System and push it in un...

Страница 6: ...o position Foot Control provides the capability to increase the front panel Power dial setting When lighted indicates Foot Control is fully depressed and System is functioning in Boost mode Lavage Flo...

Страница 7: ...st motion DO NOT FORCE 6 3 Cavitron 30K Ultrasonic Inserts The many styles of Cavitron 30K Ultrasonic Inserts are easily interchangeable for various procedures and applications See enclosed booklet fo...

Страница 8: ...depressed so adequate fluid will be available to cool tip tooth interface In general it is suggested that a feather light touch be used both supra and subgingivally The motion of the activated tip an...

Страница 9: ...lying an approved non immersion type disinfectant solution carefully following the instructions provided by the disinfectant solution manufacturer To clean system generously spray disinfectant solutio...

Страница 10: ...epth 24 1 cm Handpiece Cable 2 0 m Foot Control Cable 2 4 m Power Cord 2 1 m Water Supply Line 2 4 m Air Supply Line 2 5 m Footswitch Not for operating theatres Protection Class 1PXO Operating Environ...