75
(15) Data verification conditions and data editing conditions
Items Parameters
Defaults
Refer
to:
Code type in data editing
Selectable from codes available
Any code
(Note 1)
Enable
Transmit data regardless of the results
Disable
√
Data string extraction mode
√
Extraction block mode
Data extraction mode
AI mode
First position
Last position
Data string extraction mode
- Start position
Specified position
√
Last character
√
Specified digits
Data string extraction mode - End position
Specified position
Data string extraction mode
- Specified position for extraction start
position
0001 to 9999 positions
(Specify with ASCII characters)
1
Data string extraction mode
- Specified position for extraction last
position
0001 to 9999 positions
(Specify with ASCII characters)
9999
Extraction block mode
- Extraction block number
(Maximum 3 blocks)
01 to 99 positions
(Specify with ASCII characters)
Not specified.
Section 7.1
(Note 1)
Selecting "Any code" edits all types of codes.
: Can be changed only with the configuration software.
Содержание QK20-R
Страница 1: ...2D Code Scanner Fixed type QK20 R QK20 U User s Manual...
Страница 94: ...83 Header USB keyboard interface None default STX ETX CR LF CR LF TAB ESC ENTER Right Ctrl...
Страница 95: ...84 Header USB keyboard interface...
Страница 96: ...85 Terminator USB keyboard interface None STX ETX CR LF CR LF TAB ESC ENTER default Right Ctrl...
Страница 120: ......
Страница 121: ...2D Code Scanner Fixed type QK20 R QK20 U User s Manual First Edition January 2011 DENSO WAVE INCORPORATED...
Страница 122: ...DENSO WAVE INCORPORATED 4 2 12 Toranomon Minato ku Tokyo Japan 105 0001 http www denso wave com...