23
(2) AI parenthesizing mode
In this mode, the scanner parenthesizes AIs contained in data read and outputs the edited data according to the
extraction conditions.
Extraction conditions
Extraction conditions
Choices
"Data transfer regardless of error result"
Permit/Prohibit
If the scanner fails to extract an AI-prefixed element string when the "Data transfer regardless of error result" is
permitted, it outputs the data read as is without editing.
Example Header: STX, Terminator: ETX, Scanner ID: Disable, Code ID mark: Disable,
Transmission of the number of digits: Disable, Prefix/Suffix: None, BCC: Disable
Extraction conditions
Data read
Output data
0194901234567894110308081303
081017040208
[STX](01)94901234567894(11)030
808(13)030810(17)040208[ETX]
"Data transfer regardless
of error result": Prohibit
0194901234567894110308081303
081061704020817040305
Error (Note 1)
0194901234567894110308081303
081017040208
[STX](01)94901234567894(11)030
808(13)030810(17)040208[ETX]
"Data transfer regardless
of error result": Permit
0194901234567894110308081303
081061704020817040305
[STX]0194901234567894110308081303
081061704020817040305[ETX]
(Note 1) Data from the head to element string 030810 prefixed with AI (13) can be normally extracted, but the
following data (as underlined below) causes an error since it starts with 6 that cannot start any AI.
(01)94901234567894(11)030808(13)03081061704020817040305
Содержание QK20-R
Страница 1: ...2D Code Scanner Fixed type QK20 R QK20 U User s Manual...
Страница 94: ...83 Header USB keyboard interface None default STX ETX CR LF CR LF TAB ESC ENTER Right Ctrl...
Страница 95: ...84 Header USB keyboard interface...
Страница 96: ...85 Terminator USB keyboard interface None STX ETX CR LF CR LF TAB ESC ENTER default Right Ctrl...
Страница 120: ......
Страница 121: ...2D Code Scanner Fixed type QK20 R QK20 U User s Manual First Edition January 2011 DENSO WAVE INCORPORATED...
Страница 122: ...DENSO WAVE INCORPORATED 4 2 12 Toranomon Minato ku Tokyo Japan 105 0001 http www denso wave com...