(7) Data transmission format exclusive to RS-232C interface/USB-COM interface
Items Parameters
Defaults
Refer
to:
NONE
STX
Header when transmitting
User-defined
NONE
ETX
CR
LF
CR LF
Terminator when transmitting
User-defined
NONE
Terminator when receiving
STX
ETX
CR
LF
Terminator when receiving
CR LF
Enabled
Transmission of BCC
Disabled
Chapter 12
Section 12.4
: Can be changed only with the configuration software.