background image

(2) AI parenthesizing mode 

In this mode, the scanner parenthesizes AIs contained in data read and outputs the edited data according to the extraction 

conditions. 

 Extraction conditions 

Extraction conditions 

Choices 

"Data transfer regardless of error result" 

Permit/Prohibit 

 

If the scanner fails to extract an AI-prefixed element string when the "Data transfer regardless of error result" is permitted, it 

outputs the data read as is without editing. 

Example 

Header: STX, Terminator: ETX, Scanner ID: Disable, Code ID mark: Disable, 

 

Transmission of the number of digits: Disable, Prefix/Suffix: None, BCC: Disable 

Extraction 

conditions 

Data read 

Output data 

0194901234567894110308081

303 

081017040208 

[STX](01)94901234567894(11)030808(13)030810(17)040208[E

TX] 

"Data transfer 

regardless of error 

result": Prohibit 

0194901234567894110308081

303 

081061704020817040305 

Error (Note 1) 

0194901234567894110308081

303 

081017040208 

[STX](01)94901234567894(11)030808(13)030810(17)040208[E

TX] 

"Data transfer 

regardless of error 

result": Permit 

0194901234567894110308081

303 

081061704020817040305 

[STX]01949012345678941103080813030 

81061704020817040305[ETX] 

(Note 1) Data from the head to element string 030810 prefixed with AI (13) can be normally extracted, but the following 

data (as underlined below) causes an error since it starts with 6 that cannot start any AI. 

 (01)94901234567894(11)030808(13)03081061704020817040305 
 

30

 

Содержание QB30-SR

Страница 1: ...2D Code Scanner Fixed type QB30 SR QB30 SU User s Manual...

Страница 2: ...t s product s data processing system s or equipment or software not supplied from DENSO WAVE ii the use of DENSO WAVE s products in a manner for which the same were not intended nor designed or iii an...

Страница 3: ...ting Data 24 8 2 1 Data extraction mode 24 8 2 1 1 Extracting a data string 24 8 2 1 2 Extracting data blocks 26 8 2 1 3 Extracting AI Application Identifier prefixed strings 28 8 2 2 Data substitutio...

Страница 4: ...hapter 15 Live Mode Function 73 Chapter 16 Parameters and Defaults 74 Chapter 17 QR Coded Parameter Menu 97 17 1 Parameter Setting Procedure Using the QR coded Parameter Menu 97 17 2 Parameter Setting...

Страница 5: ...have finished reading this manual keep it handy for speedy reference Note Do not use this scanner in an environment with electrical noise that can trigger malfunction Note Specifications described in...

Страница 6: ...r new products Free web information service QBdirect QBdirect Service Contents Information search service FAQ Offers detailed information on each product Download service Offers downloads of repair mo...

Страница 7: ...onditions that could cause serious bodily injury or death if the instructions are not followed correctly CAUTION Alerts you to those conditions that could cause minor bodily injury or substantial prop...

Страница 8: ...ere any inflammable gases may be emitted Doing so could cause fire Do not scratch modify bend twist pull or heat the power cable of the AC adapter Do not place heavy material on the cable or allow the...

Страница 9: ...ng in a fire Always use the scanner and AC adapter in a well ventilated area Keep the power cable of the AC adapter away from any heating equipment Failure to do so could melt the sheathing resulting...

Страница 10: ...broken lead wires stop using it and contact your nearest dealer Failure to do so could result in a fire or electrical shock During electrical storm activity always unplug the AC adapter from the wall...

Страница 11: ...areas therefore periodically check the clear plate and clean it if dusty To clean the plate first blow the dust away with an airbrush Then wipe the plate with a cotton swab or the similar soft one ge...

Страница 12: ...elow for details Interface cable Use the cable to connect your scanner to a host computer or other equipment POWER LED POWER LED lights when the power is on READ LED READ LED lights in blue when a rea...

Страница 13: ...on the device is used for setting up Nominal diameter and pitch of the screw used and the depth of the screw for the device are M3 0 5mm and 6mm respectively 0 315 N m is recommended for the tighteni...

Страница 14: ...specifications refer to Chapter 12 Section 12 3 You can switch between the USB COM interface and USB keyboard interface by using the QR coded parameter menu provided in Chapter 12 or the configuration...

Страница 15: ...d Output 6 GND Ground 7 No Connection Unconnected 1 8 COM IN Input common 2 Input Output 9 TRIGGER Input TRIGGER Input 10 RESET Input RESET Input 11 OUT1 Output terminal1 3 Output Viewed from pin side...

Страница 16: ...nector Output Specifications NPN open collector Rated load DC30V 50mA Residual voltage when ON 1 0V or less 50mA Leakage current when OFF 0 1mA or less Note When disconnecting the interface cable or D...

Страница 17: ...M port is open with the USB COM interface being used Hot plugging unplugging under this condition will lose data When the host computer is processing the scanner connection do not plug or unplug any o...

Страница 18: ...rt even if a USB device is unplugged so the driver always occupies a COM port number The driver cannot coexist with conventional Denso USB COM device drivers in a host computer In the installation pro...

Страница 19: ...If the message shown at left appears the conventional driver is running on the computer Terminate the application using the COM port of the driver remove the corresponding USB device and then click OK...

Страница 20: ...een to appear and then select Yes Y 3 Wait for the InstallShield Wizard screen to appear and then click Next 4 Check that the USB device scanner to be connected is not plugged in the computer and then...

Страница 21: ...is not allowed to assign two or more USB ports to a single COM port To use two or more USB ports with a single USB device by turns you need to run the Setup exe by the same number of times as the num...

Страница 22: ...5 Wait for the wizard to start searching for the USB driver 6 Wait for the USB driver to be found and for the caution message for driver s digital signature to appear then click Continue Anyway to pro...

Страница 23: ...k tray s shows the Unplugging DENSO WAVE USB Device COMx Changing a COM port number can change a COM port number SB device Changing a COM port number sometimes When the USB device scanner is being con...

Страница 24: ...iver setup wizard Follow the wizard and set up the driver The setup procedure on each of Windows XP and Windows Vista is described below Follow the wizard for Windows 7 as well Windows XP 1 Switch the...

Страница 25: ...configuration the screen shown at left automatically disappears 4 Wait for the USB Human Interface Device hint to pop up on the task tray 5 To check whether the USB device is working normally open the...

Страница 26: ...w To read the same code again after successful read therefore pull the mobile away from the scanning window for at least half a second to release the double read prevention function Note that if you k...

Страница 27: ...via the RS 232C interface or USB COM interface it is not via the USB keyboard interface The configuration software also offers batch process QR code symbols for read by scanners in the field Those sy...

Страница 28: ...detected due to low illumination etc the scanner will not enter the Active state Ambient illumination of 500lx or more is necessary Note2 There may be times when the unit switches between the Active...

Страница 29: ...ding timing ON OFF Direct Trigger mode Indirect trigger mode Direct or indirect software trigger mode One shot time for indirect mode Note 1 Trigger input delay time ON OFF OFF ON READON command READO...

Страница 30: ...f the verification digit can be specified The output format for the verification result can be selected with the position of the verification digit and verification result output format being set usin...

Страница 31: ...verification digit position is designated Only the designated digit position is compared if a verification digit position is designated and the verification master and number of digits data length in...

Страница 32: ...istration are as follows Comman d Details ESTART Starts master data registration EEND End master data registration EF Master registration command The registered master s is deleted when the power is t...

Страница 33: ...t position is designated and the verification master and number of digits data length in the scanned code data are ignored Unlike Scan entry mode however the verification master is always used to perf...

Страница 34: ...de the concatenated data is registered by the master data in the same order as the scanning of code data Scan data verification To scan a multi line barcode all the code marks in respective rows shall...

Страница 35: ...ctions from code data read and then outputs it The data block extraction is available only when code data is in the comma delimited CSV format The AI prefixed string extraction is available for GS1 12...

Страница 36: ...position STX Q0003123 ETX Tail position 3rd position STX Q0003345 ETX 1st position Tail position STX Q000512345 ETX 1st position By 3 positions STX Q0003123 ETX 2nd position 4th position STX Q0003234...

Страница 37: ...ces Any code QR Code iQR Code PDF417 Data Matrix MaxiCode Aztec UPC A EAN 13 UPC E EAN 8 Code 128 GS1 128 EAN 128 Codabar NW 7 Code 39 Code 93 Interleaved 2of5 ITF GS1 DataBar RSS Code type EAN UCC Co...

Страница 38: ...23 456 7890 2 and 5 STX ETX STX 7890 ETX 1 23 456 7890 5 Error 1 23 456 7890 4 and 5 Error Code type QR Code Data transfer regardless of error result Prohibit 1234567890 1 and 2 Error 1 23 456 7890 5...

Страница 39: ...ed to each element string if their transmissions are enabled The number of digits is the count of each element string edited Example Data read 01 94901234567894 11 030808 13 030810 Header STX Terminat...

Страница 40: ...17 STX 040208 040305 ETX 12 Error 01 12 Error 01 01 Error Data transfer regardless of error result Prohibit 01 11 17 STX 94901234567894 030808 040208 ETX 17 11 STX 040208 030808 ETX 17 17 STX 040208 0...

Страница 41: ...able Extraction conditions Data read Output data 0194901234567894110308081 303 081017040208 STX 01 94901234567894 11 030808 13 030810 17 040208 E TX Data transfer regardless of error result Prohibit 0...

Страница 42: ...ndary Serial Number 251 n3 an 30 Reference to Source Entity 252 n3 n27 Global Serial Number 30 n2 n 8 Quantity 310n n4 n6 Net Weight Kilograms 311n n4 n6 Length or 1st Dimension Meters 312n n4 n6 Widt...

Страница 43: ...rea Square Feet Logistics 355n n4 n6 Area Square Yards Logistics 356n n4 n6 Net Weight Troy Ounces 357n n4 n6 Net Volume Ounces 360n n4 n6 Volume Quarts 361n n4 n6 Volume Gallons 362n n4 n6 Gross Volu...

Страница 44: ...8002 n4 an 20 Cellular Mobile Telephone Identifier 8003 n4 n14 an 16 EAN UCC Global Returnable Asset Identifier GRAI 8004 n4 an 30 EAN UCC Global Individual Asset Identifier GIAI 8005 n4 n6 Price Per...

Страница 45: ...fixed length Up to 3 numeric characters an an3 an 3 Alphanumeric characters 3 alphanumeric characters fixed length Up to 3 alphanumeric characters Note 1 If the specified AI is variable in length and...

Страница 46: ...s Choices Any code QR iQR Code PDF417 Data Matrix MaxiCode Aztec UPC A EAN 13 UPC E EAN 8 Code 128 GS1 128 EAN 128 Codabar NW 7 Code 39 Code 93 Interleaved 2of5 ITF GS1 DataBar RSS Code type EAN UCC C...

Страница 47: ...lts in an error Blocksorting conditions Blocksorting conditions Choices Any code QR iQR Code PDF417 Data Matrix MaxiCode Aztec UPC A EAN 13 UPC E EAN 8 Code 128 GS1 128 EAN 128 Codabar NW 7 Code 39 Co...

Страница 48: ...sidue calculation e g transformation of units 7 Substituting data 8 Comparing character strings 9 Driving indicator LED and beeper The ADF script mode can be programmed with the configuration software...

Страница 49: ...scanning is not completed during decode time scanners decode again Decade time can be set with commands QR Code menu and configuration software QB Setting 2 Decode time Decode time differs from the t...

Страница 50: ...d to the host computer When scanning structured append QR Code symbols the scanner beeps in a different way from usual That is when the scanner reads the first structured append code it beeps twice an...

Страница 51: ...ecifying this format allows the scanner to output multiple lines of barcode data delimited with commas in the data transmission format selected see Section 12 4 Note that the scanner outputs the code...

Страница 52: ...ansmission error or timeout occurred when the scanner was communicating with the configuration software QB Setting the encryption key of data read does not match the one configured in the scanner in S...

Страница 53: ...QR coded parameter menu or configuration software QB Setting The factory default is High Each time the Beeper volume QR Code symbol is read the beeper volume cycles as shown below Low Medium High Eve...

Страница 54: ...ation 3 Command setting Indication Green I The scanner receives the START command and flashes when in setting mode 4 Scanning ON OFF mode When the magic key is set to the scanning ON OFF mode in the C...

Страница 55: ...en performing data verification If an error occurs during master code registration when performing data verification When unable to save settings When an execution error occurs with ADF script When th...

Страница 56: ...nable to perform reading In this case push down the magic key for approximately 2 seconds to forcibly complete execution of the ADF script 3 Temporary cancellation of the barcode reader mode QB30 SU o...

Страница 57: ...me is set with a fixed value and the gain is calculated automatically The shutter time can be set at 0 1ms intervals from 0 1ms 9 9ms The shutter time is set using the commands or the configuration so...

Страница 58: ...nal is output by turning the OUTPUT Tr transistor ON at a specific timing to indicate the successful completion of scanning Note 1 5 Verification NG signal When using the verification function this si...

Страница 59: ...FF ON Scan timing Synchronous mode Data output Decode Success Data output Asynchronous mode Success NG output OK output Success OFF ON Scan timing NG signal output OK signal output Synchronous mode Su...

Страница 60: ...al The scanner output the SHT signal that synchronize to the exposure operation of the scanner from the output terminal 2 when the output terminal 2 is set in the SHT signal Polar character of the SHT...

Страница 61: ...n software QB Setting provide CTS timeout and ACK NAK response settings each from 100 ms to 9 9 s in 100 ms increments 2 RTS signal control protocol You can select either the scanner ready mode or the...

Страница 62: ...n confirm the COM port number on the Windows Device Manager or the like before use If you want to use two or more communications processors software or scanners concurrently on your computer be sure t...

Страница 63: ...d then processes a response If the response is an ACK the scanner normally ends the transmission if it is a NAK the scanner transmits the code data again Note The command and configuration software QB...

Страница 64: ...to data read from the following No conversion ASCII default Outputs 00h to 7Fh data in ASCII format bytewise Selecting this parameter does not output 80h to FFh data Binary conversion Converts 00h to...

Страница 65: ...or None TAB ESC ENTER default or others For details refer to Chapter 11 2 Scanner ID A scanner ID is a unique serial number assigned to an individual scanner at the time of shipment It consists of six...

Страница 66: ...Q Q Edit mode Q Q Batch edit mode Q Q QR Code Unedit mode S S Micro QR Code Q Q SQRC Q Q iQR Code G G Edit mode G G iQR Code Unedit mode S S MaxiCode X X PDF 417 Y Y Micro PDF 417 Y Y Square Z Z Data...

Страница 67: ...None Linear A F EAN 13 With five digit Add on Add on None None No Add on B FF Linear B FF With two digit Add on Add on None None Linear B FF EAN 8 With five digit Add on Add on None None Interleaved...

Страница 68: ...13 With 5 digit add on Add on None None None None EAN 13 CC A EAN 13 CC B CC A CC B None Y Note 2 None Y Note 2 Without add on V C V E Linear component V C V E With 2 digit add on Add on None None Non...

Страница 69: ...near component A X3 X0 With 2 digit add on Add on None None X1 Note 2 Linear component A X3 X0 UPC A With 5 digit add on Add on None None X2 Note 2 Without add on A X0 Linear component A X3 X0 With 2...

Страница 70: ...2 Without add on T A E0 Linear T A E3 E0 With 2 digit add on Add on None None None E1 Note 2 Linear T A E3 E0 EAN 13 With 5 digit add on Add on None None None E2 Note 2 EAN 13 CC A EAN 13 CC B CC A CC...

Страница 71: ...racter position from start code 0 No option 1 FNC1 followed by the 1st message character 2D codes Aztec 2 FNC1 following the 1st character or pair digits 0 Scanning enabled without a check digit 1 Sca...

Страница 72: ...a is selected the following format applies X1 X2 Xn 1 Xn Y1 Y2 Ym 1 Ym When Transmit only non disclosure data is selected the following format applies Y1 Y2 Ym 1 Ym PDF417 MicroPDF417 MaxiCode Data Ma...

Страница 73: ...e 4 and Code ID mark output mode Separating For details about the code ID mark refer to 5 Code ID mark on 12 4 The conversion to the GTIN format or to the UPC A are selectable For the GTIN format conv...

Страница 74: ...o the host EAN 13 with add on A code ID mark precedes add on code data under the conditions Code ID mark Type 4 and Code ID mark output mode Separating For details about the code ID mark refer to 5 Co...

Страница 75: ...selection The conversion to the GTIN format is also selectable For the GTIN format conversion refer to Section 12 5 Code 93 The scanner transmits code data read excluding start and stop codes and a ch...

Страница 76: ...omponent and are inserted between the linear component and 2D Composite component For details about the code ID mark refer to 5 Code ID mark on section 12 4 You can select whether or not to transmit c...

Страница 77: ...AN8 do not apply UPC A Data read 0 S X1 X2 X3 X4 X5 X6 X7 X8 X9 X10 C D 0 Padding character for adjustment of the data length S Number system character Conversion to 16 digit GTIN format AI 01 and PI...

Страница 78: ...0 X1 X2 X3 X4 0 0 0 0 0 X C D 2 5 X6 5 9 PI 0 0 X1 X2 X3 X4 X5 0 0 0 0 X6 C D 2 2 Check digits are calculated again and transferred regardless of the transmission specified UPC E with add on Data rea...

Страница 79: ...d transferred regardless of the transmission specified Conversion to 14 digit GTIN format PI added PI P1 P2 P3 X1 X2 X3 X4 X5 X6 X7 X8 X9 C D 2 2 Check digits are calculated again and transferred rega...

Страница 80: ...6 digit GTIN format AI 01 and PI added With 2 digit add on 0 1 PI 0 0 0 0 0 P1 P2 X1 X2 X3 X4 X5 C D X6 X7 1 With 5 digit add on 0 1 PI 0 0 0 0 0 P1 P2 X1 X2 X3 X4 X5 C D X6 X7 X8 X9 X10 1 1 Check dig...

Страница 81: ...ck digits are calculated again and transferred regardless of the transmission specified If the transmission of a code ID mark is enabled in the scanner the code ID mark of EAN 13 is transferred Conver...

Страница 82: ...scanning QR Code SQRC iQR Code and DataMatrix code Note2 This is valid only when scanning QR Code SQRC iQR Code DataMatrix and Aztec With QR Code SQRC and iQR Code the model version error correction...

Страница 83: ...age within a single trigger interval 5 Save the last unsuccessful image within a single trigger interval 6 Save the last unsuccessful image within a single trigger interval when the scan is not succes...

Страница 84: ...ured images to the host on a real time basis This function can be used for configuration software only QB Setting Note 1 Transmission protocol of the images to the host system etc is X modem 1K regard...

Страница 85: ...tion time Double scan prevention time Setting range 0 1 9 9 seconds 0 5 seconds Chapter 5 Disabled Decode limitation time 0 05s 9 99 s Chapter 8 Section 8 5 Automatic Fixed shutter Variable gain Lumin...

Страница 86: ...B30 SU only Items Parameters Defaults Refer to USB COM interface Note 1 Interface USB keyboard interface Note 1 Chapter 12 Note 1 Selecting the USB keyboard interface disables access to the configurat...

Страница 87: ...Disable CTS signal monitoring time 0 1 to 9 9 seconds 2 s ACK NAK response confirmation time 0 1 to 9 9 seconds 1 s Scanner ready mode RTS signal control protocol Data ready mode Chapter 12 1 4 Commu...

Страница 88: ...wedish 102 key type Chapter 12 Section 12 3 Keyboard type Japanese 106 key type Inboard numeric keys Numeric key selection 0 to 9 Numeric keypad None ASCII Binary conversion Binary data conversion See...

Страница 89: ...ata transmission format Enabling this function substitutes E7h to FDh data with the special keys as listed below and transmits the substituted data to the host The Left SHIFT Left CTRL and Left ALT ar...

Страница 90: ...Prefix transmission Disable Enable Suffix transmission Disable Enable Scanner ID output Disable Chapter 12 Section 12 4 Enable GTIN format conversion Disable Conversion to 16 digits Conversion to 14 d...

Страница 91: ...r to NONE STX Header when transmitting User defined NONE ETX CR LF CR LF Terminator when transmitting User defined NONE Terminator when receiving STX ETX CR LF Terminator when receiving CR LF Enabled...

Страница 92: ...ce Items Parameters Defaults Refer to NONE STX ETX CR LF CR LF TAB ESC ENTER Right Ctrl Header User defined NONE STX ETX CR LF CR LF TAB ESC ENTER Right Ctrl Terminator User defined Chapter 12 Section...

Страница 93: ...1 40 40 Enable Reading MicroQR Disable MicroQR Code minimum version readable 1 MicroQR Code maximum version readable 1 to 4 4 Chapter 12 Section 12 4 Enabled Reading SQRC Disabled Chapter 8 Section 8...

Страница 94: ...uare Disabled Enabled Reading Data Matrix rectangular Disabled Chapter 12 Section 12 4 Data Matrix Square minimum code number readable 1 Data Matrix Square maximum code number readable 1 to 24 24 Data...

Страница 95: ...possible to simultaneously enable disable square or rectangular at the QR Code parameter menu Note5 It is possible to simultaneously enable disable Full Range or Compact the QR Code Note6 Only enable...

Страница 96: ...eck digit Disable Enable EAN 13 transmission of country code Disable Enable EAN 13 conversion to the ISBN ISSN format Disable Enable Reading UPC E Disable Section 12 4 Enable UPC E transmission of che...

Страница 97: ...ding Interleaved 2of5 Disable Chapter12 Section 12 4 Minimum number of readable digits for Interleaved 2of5 4 digits Maximum number of readable digits for Interleaved 2of5 2 to 99 digits 99 digits See...

Страница 98: ...the scanner can actually read Code 128 EAN 128 GS1 128 Items Parameters Defaults Refer to Enable Reading Code 128 Disable Enable Reading EAN 128 GS1 128 Disable Chapter 12 Section 12 4 Minimum number...

Страница 99: ...4 Disabled Transmit GS Transmission of FNC1 for GS1 DataBar RSS Expanded code User Selection 1 digit 1 digit Min number of digits to be scanned for GS1 Data Bar RSS Expanded code 99 digits 1 digit Max...

Страница 100: ...1 DataBar Stacked Omnidirectional Note 3 In the QR Code menu the GS1 DataBar RSS codes cannot separately be selected and they are enabled or disabled all together Note 4 In the QR Code menu the COMPOS...

Страница 101: ...of readable digits Max 99 digits Not specified Second line barcode Selectable from readable bar codes Not specified Second line barcode character Up to 2 ASCII characters Not specified Second line bar...

Страница 102: ...aster designation in file entry mode Disabled Verification master number in file entry mode 1 50 1 Enabled Verification digit position designation in file entry mode Disabled Verification start positi...

Страница 103: ...signal READY signal Setting external terminal 1 Unused External illumination synchronized signal OK signal NG signal Verification OK signal Verification NG signal READY signal Setting External termin...

Страница 104: ...no of position Extraction start position for data string extraction 0001 to 9999 digits in ASCII characters 1 digit Extraction end position for data string extraction 0001 to 9999 digits in ASCII cha...

Страница 105: ...bled Enabled AI Split mode AI3 designation enable disenable Disabled AI Split mode AI1 specified Specified from AI candidates Note 2 00 AI Split mode AI2 specified Specified from AI candidates Note 2...

Страница 106: ...t successful image within the trigger Save the last successful image within the trigger Save all images within the trigger Save the first unsuccessful image within the trigger Save the last unsuccessf...

Страница 107: ...Scanner sensitivity level in Auto sensing mode Low Chapter 7 Enabled Beeper control Disabled Enabled Reading error beeper control Disabled Low pitch tone approx 2 6kHz Medium pitch tone approx 2 8kHz...

Страница 108: ...de symbol in the QR coded parameter menu makes all items in the menu revert to the factory default 17 2 Parameter Setting Procedure Using the QR coded Parameter Menu Control command See annex 2 enable...

Страница 109: ...black background is set Cancel All defaults End setting The beeper volume can be set by scanning the following QR Code symbol only No Start setting or End setting QR Code symbol required to be scanne...

Страница 110: ...232C interface USB COM Interface Procedure Non acknowledge mode default ACK NAK mode Transmission speed QB30 SR only 4800 bps 9600 bps 19200 bps 38400 bps default 57600 bps 115200 bps Data length QB30...

Страница 111: ...Parity QR30 SR only None default Even parity Odd parity Stop bit QB30 SR only 1 bit default 2 bits Header when transmitting None STX 100...

Страница 112: ...Terminator when transmitting None ETX CR LF CR LF 101...

Страница 113: ...Header when receiving None STX Terminator when receiving ETX CR LF CR LF Transmission of BCC Disabled Enabled 102...

Страница 114: ...USB interface to the host USB COM interface default USB keyboard interface 103...

Страница 115: ...rameters for USB keyboard interface Conversion to binary data No conversion default ASCII Binary conversion Kanji conversion Header USB keyboard interface None default STX ETX CR LF CR LF TAB ESC ENTE...

Страница 116: ...Header USB keyboard interface Terminator USB keyboard interface None STX ETX CR LF CR LF TAB ESC ENTER default Right Ctrl 105...

Страница 117: ...minator USB keyboard interface Data transmission format Transmission of code ID mark Disable default Enable Transmission of the number of digits Disable default Enable in 2 digits Enable in 4 digits 1...

Страница 118: ...d white inverted codes Black cells bars on a white background default White cells bars on a black background Automatically identify black and white inverted codes Scanning split QR Code Structured App...

Страница 119: ...Matrix Disable Enable default Bar codes Scanning UPC A UPC E EAN 13 and EAN 8 Disable Enable default Scanning Interleaved 2of5 Disable Enable with a check digit Check digit transmission disabled Enabl...

Страница 120: ...nning Codabar NW 7 Disable Enable without a check digit default Enable with a check digit Check digit transmission enabled Enable with a check digit Check digit transmission disabled Transmission of s...

Страница 121: ...ck digit transmission enabled Enable with a check digit Check digit transmission disabled Transmission of start stop codes for Code 39 Disable default Enable Scanning Code 93 Disable default Enable Sc...

Страница 122: ...ther settings Scanning mode Continuous reading mode A Continuous reading mode B Direct trigger mode Indirect trigger mode Direct software trigger mode Indirect software trigger mode Auto sense mode 11...

Страница 123: ...Beeper control Disable Enable default Indicator LED Disable Enable default 112...

Страница 124: ...nner requires a maximum of one second to be ready to receive control commands 1 Outline of the command settings Type of commands The command can be classified as follows Command Details 1 Setting cont...

Страница 125: ...d The commands are followings Note Reply with NG even if the commands other than indirect commands are received until it ends with END after starting the setting with START Note Indirect commands can...

Страница 126: ...e Change WR0C nnn NNN Confirmation RD0C OK nnn NNN 000 000 Verification digit pos designation disabled nnn NNN Verification from nnn to NNN 001 255 Verification result output Scan entry mode Change WR...

Страница 127: ...etting Note1 Change WR1C nn Confirmation RD1C OK n 0 Always off n n 1 Automatic n 2 Always on Decode time setting Note 1 Change WR1D nnn Confirmation RD1D OK nnn 000 Disabled No decode time setting nn...

Страница 128: ...No C D scanning enabled n n 1 With C D scanning enabled n 2 Scanning disabled CODABAR NW 7 code scanning Change WR47 n Confirmation RD47 OK n 0 No C D scanning enabled n n 1 With C D scanning enabled...

Страница 129: ...WR4J n Confirmation RD4J OK n 0 Enabled Note 4 n n 1 Disabled Micro PDF417 scanning Change WR4K n Confirmation RD4K OK n 0 Enabled n n 1 Disabled Barcode reader mode Change WR4L n Confirmation RD4L OK...

Страница 130: ...ay not be scanned due to some restrictions such as the field of view of the decoder n m 0 0 Ver no restriction Note 3 Readable codes when GS1 DataBar RSS scanning is enabled are as follows GS1 DataBar...

Страница 131: ...er versions may not be scanned due to restrictions such as the field of view nn mm 00 00 Ver no restriction Note 9 Designation of upper case or lower case is disabled The characters set up currently a...

Страница 132: ...27 OK n 0 Disabled n n 1 Enabled CTS signal control Change WR28 n Confirmation RD28 OK n 0 No control n n 1 control CTS monitoring time Change WR29 nnn Confirmation RD29 OK nn 01 99 nn 0 1 9 9s ACK NA...

Страница 133: ...Set scan test Change WR51 nmlpq Confirmation RD51 OK nmlpq Note 1 The QB30 switches to Scanning Test with Test analysis start TESTON nnn and then after receiving the following test commands returns t...

Страница 134: ...n RD37 OK n 0 Enabled n n 1 Disabled Beeper beeping when power is on Change WR38 n Change RD36 OK n 0 Enabled n n 1 Disabled Error Processing Conditions Response Received an undefined command Header a...

Страница 135: ...ns conditions of the scanner are different from those of the connected host Change the communications conditions of the scanner to match those of the connected host Any device driver other than our Ac...

Страница 136: ...anning specifications Reading confirmation READ LED Blue Green and Red and beeper RS 232C Interface QB30 SR RS 232C asynchronous Operating voltage range 5V DC 5 Input power requirements RS 232C Consum...

Страница 137: ...zon near point far point code Cell size mm distance field of view distance field of view 0 2 20 36 23 35 55 35 0 25 45 68 43 0 33 60 88 56 0 42 75 107 68 two dimensional codes 0 5 80 113 72 0 25 55 81...

Страница 138: ...Fixed Type 2D Code Scanner QB30 SR SU User s Manual First Edition July 2012 DENSO WAVE INCORPORATED...

Страница 139: ...DENSO WAVE INCORPORATED 1 Yoshiike Kusagi Agui cho Chita gun Aichi 470 2297 Japan http www denso wave com...

Отзывы: