Chapter 9
Beeper, Indicator LED, Illumination LEDs, and Magic key
9.1
Beeper
(1) Beeping
The scanner emits a short or long beeps, once or a couple of times as described below.
The beeper emits
a short beep
when:
- the scanner has read a code successfully,
- code data read matches the master data in the data verification mode,
- the scanner has read a split QR Code symbol,
- the "Start setting" or "End setting" code is read (3 beeps) or the parameter setting QR Code symbols are read (1 beep) from
the QR-coded parameter menu (given in Chapter 17),
- the configuration software (QB Setting) starts up or accepts new settings (3 beeps), or
- the scanner has read a batch-process QR Code symbol generated with the configuration software (QB Setting) (3 beeps).
The beeper emits
a long beep
when:
- code data read does not match the master data in the data verification mode,
- the scanner has read split QR Code symbols in edit mode and the accumulated data exceeds 8 kilobytes,
- a master code has the wrong number of digits during registration of master data,
- a code other than a parameter setting code is read during parameter setting by the QR-coded parameter menu,
- a transmission error or timeout occurred when the scanner was communicating with the configuration software (QB Setting),
- the encryption key of data read does not match the one configured in the scanner in SQRC scanning (when the "data
transmission after mismatch of encryption key" is disabled),
- a communications error has occurred, or
- an invalid control command is received.
When the scanner is turned on, the configuration software (QB Setting) provides a choice of beeper ON/OFF (default: ON),
but does not provide a choice of beeper tone.
You can disable the beeper using the QR-coded parameter menu or configuration software (QB Setting). In any of the
following cases, however, the beeper sounds regardless of that beeper setting:
- when you make settings by scanning the QR-coded parameter menu,
- when the scanner receives a beeper-ON command from the host computer,
- when the configuration software (QB Setting) starts up or any setting you have made is established,
- when the scanner reads a batch-process QR Code symbol,
- when the execution error occurs at ADF script,
- when the power is on,
- when the scanner receives the start command of the control command and quit command.
- when registration of master data of data verification scanning is completed
- when the beeper of scanning completion during scanning test is set at the QR Code menu (chapter 17)
41
Содержание QB30-SR
Страница 1: ...2D Code Scanner Fixed type QB30 SR QB30 SU User s Manual...
Страница 112: ...Terminator when transmitting None ETX CR LF CR LF 101...
Страница 113: ...Header when receiving None STX Terminator when receiving ETX CR LF CR LF Transmission of BCC Disabled Enabled 102...
Страница 114: ...USB interface to the host USB COM interface default USB keyboard interface 103...
Страница 123: ...Beeper control Disable Enable default Indicator LED Disable Enable default 112...
Страница 138: ...Fixed Type 2D Code Scanner QB30 SR SU User s Manual First Edition July 2012 DENSO WAVE INCORPORATED...
Страница 139: ...DENSO WAVE INCORPORATED 1 Yoshiike Kusagi Agui cho Chita gun Aichi 470 2297 Japan http www denso wave com...