![Denso QB30-SR Скачать руководство пользователя страница 83](http://html1.mh-extra.com/html/denso/qb30-sr/qb30-sr_user-manual_2483285083.webp)
Chapter 14 Image Memory Function
The image memory function enables the scanner to store the captured image on a temporary basis.
The Images taken from the scanner can be confirmed on the configuration software (QB Setting) or transferred to the host
computers. Storing the non-scannable image enables to analyze the causes.
Note: When the power is off, the image is not stored. Be sure to upload the data to the host computers before turning the
power off.
Number of images
:
10
Image type:
:
Gray image BMP images (256 gradations)
Image upload protocol
:
X-modem (1K)
Scannable Image
The images below can be captured at each of continuous mode and trigger mode.
*Image Capture mode (Continuous reading mode)
1. Save all captured images
2. Save all unsuccessful images
3. Save all successful images
*Image Capture mode (Trigger mode)
1. Save all images within a single trigger interval.
2. Save the first image within a single trigger interval.
3. Save the last image within a single trigger interval.
4. Save the first unsuccessful image within a single trigger interval.
5. Save the last unsuccessful image within a single trigger interval.
6. Save the last unsuccessful image within a single trigger interval when the scan is not successfully completed within a single
trigger interval.
*Image storage method
1) Write memory no. designation
Images are always overwritten to the specified memory.
2) Cyclic
Images are written to memory number #00 - #17 sequentially. The start memory cannot be specified. The image storage
memory automatically returns to #00 after #09.
(Notes)
1. When the scan is successfully completed in the trigger mode, no more images are captured, even if the last image is
designated to be saved in the trigger mode. In this case, the last scanned image is stored in the memory.
2. When captured image is stored in trigger mode, the scanning may be delayed due to ready condition maximum 10ms after
completion of scanning timing.
3. Transmission protocol of the images to the host system, etc. is X-modem (1K) regardless of the pre-set protocol.
(non-protocol or ACK/NAK mode).
4. Transmission takes abut 40 seconds at the transmission speed 115.2Kbps, but it depends on the performance of the host
system, etc.
5 The reading test can be executed.
72
Содержание QB30-SR
Страница 1: ...2D Code Scanner Fixed type QB30 SR QB30 SU User s Manual...
Страница 112: ...Terminator when transmitting None ETX CR LF CR LF 101...
Страница 113: ...Header when receiving None STX Terminator when receiving ETX CR LF CR LF Transmission of BCC Disabled Enabled 102...
Страница 114: ...USB interface to the host USB COM interface default USB keyboard interface 103...
Страница 123: ...Beeper control Disable Enable default Indicator LED Disable Enable default 112...
Страница 138: ...Fixed Type 2D Code Scanner QB30 SR SU User s Manual First Edition July 2012 DENSO WAVE INCORPORATED...
Страница 139: ...DENSO WAVE INCORPORATED 1 Yoshiike Kusagi Agui cho Chita gun Aichi 470 2297 Japan http www denso wave com...