background image

 

107 

2D Code Handy Terminal 

Upon completion of the PING test, the screen displays as shown on the 

 

rs found during the PING test. 

at took   

 

ed in center of screen)

right. 

 

The PING result may include the following: 

OK: 

Displays the number of echo replies. 

XXXX]: 

Echo reply time in milliseconds 

[X

NG: 

Displays the number of erro

TIMEOUT:  Displays the number of timeouts (for echo replies) th

place during the PING test. 

Displays the BHT IP address during the PING test only.

IP

 

 

e

M ssages displayed during PING test (display

 

Waiting:   

 

Setting up the PING test. 

Opening device:    Opening devices. 

Routing TCP/IP: 

Connecting to the TCP/IP communication pathway. 

t. 

pen a device. 

TCP/IP error:   

Failed to connect to the TCP/IP communication pathway. 

ermination messages (displayed at bottom of screen)

PING start: 

 

Starting the PING tes

Device error:   

Faiindicator LED to o

 

PING t

 

The PING test has been aborted. 

PING end: 

 

The PING test has ended normally. 

PING aborted:  

PING error: 

 

An error has occurred during the PING test. 

 

Содержание BHT-604Q

Страница 1: ...2D Code Handy Terminal User s Manual BHT 604Q 2D Code Handy Terminal ...

Страница 2: ...recautions to ensure its products do not infringe upon any patents or other intellectual property rights of other s however DENSO WAVE cannot be responsible for any patent or other intellectual property right infringement s or violation s arising from any of the following 1 The use of DENSO WAVE s products in connection or in combination with other components products devices data processing syste...

Страница 3: ...iled information on each product Download service Offers downloads of repair modules for the latest BHT Series systems or software and sample programs E mail inquiries Product related queries can be sent in by e mail Please note that these privileges may be subject to change without prior notice How to Register Access the URL below and follow the instructions provided http www qbdirect net Inquiri...

Страница 4: ...be performed prior to commencing operation Chapter 3 Basic Operation Describes basic operations performed by the operator and how to make basic changes to settings such as the beeper volume Chapter 4 System Operation Describes how to initialize and update the system start up a user program and operate System Mode Chapter 5 Communication Describes interfaces and communication specifications Chapter...

Страница 5: ...rk The PDF Bookmark function can be used to jump to the Contents page Procedure 1 Click the Bookmark tab 2 Click to search for the desired item 3 Click the item to be read 1 Click the Bookmarks tab 2 Click to search for the desired item 3 Click the item to be read ...

Страница 6: ...page by entering words or characters related to the item being searched 1 Click the Search icon Or select Edit Search 2 Enter the word s or character s to be searched for 3 Click Search 1 Click the Search icon 2 Enter the search word s or character s 3 Click Search Search Results Example ...

Страница 7: ...d in the BHT BASIC Compiler CD ROM This manual can also be downloaded from the DENSO WAVE member s Web site QBdirect BHT BASIC 4 0 Transfer Utility User s Guide This is an instruction manual for software relating to data transfer between the computer and BHT 604 and comes bundled with the BHT BASIC 4 0 Transfer Utility This manual can also be downloaded from the DENSO WAVE member s Web site QBdire...

Страница 8: ...those conditions that could cause serious bodily injury or death if the instructions are not followed correctly Alerts you to those conditions that could cause minor bodily injury or substantial property damage if the instructions are not followed correctly Meaning of Symbols A triangle with a picture inside alerts you to a warning of danger Here you see the warning for electrical shock A diagonal...

Страница 9: ... could cause fire Only use the dedicated charger for charging the rechargeable battery cartridge Using a different type of charger could cause battery rupture or leakage of battery fluid and result in a fire bodily injury or serious damage to property Handling the BHT The BHT uses a laser light for indicating the scanning range Though the intensity of the laser light is too low to inflict bodily i...

Страница 10: ...r nearest dealer Failure to do so could cause fire or electrical shock Never use the CU for charging anything other than the specified battery cartridges Doing so could cause heat battery rupture or fire Never bring any metals into contact with the output terminals Doing so could produce a large current through the CU resulting in heat or fire as well as damage to the CU Never use the CU on the li...

Страница 11: ...getting them caught in other objects or entangled in rotating machinery Failure to do so could result in accident or injury Never dis assemble Never disassemble or modify the BHT doing so could result in an accident such as break or fire Never put the BHT in places where there are excessively high temperatures such as inside closed up automobiles or in places exposed to direct sunlight Doing so co...

Страница 12: ...ming its housing resulting in a fire Always use the CU and AC adapter in a well ventilated area Do not place the CU anyplace where it may be subjected to oily smoke or steam e g near a cooking range or humidifier Doing so could result in a fire or electrical shock Keep the power cord away from any heating equipment Failure to do so could melt the sheathing resulting in a fire or electrical shock D...

Страница 13: ...cribes the BHT system and provides an overall outline of the BHT 1 1 System Configuration 2 1 1 1 System Configuration 2 1 1 2 Software Configuration 4 1 2 Component Names and Functions 7 1 2 1 BHT Front Rear 7 1 2 2 Keypad 8 1 2 3 BHT Screen 10 ...

Страница 14: ...ll differ depending on the type of communication used Host computer CU 600 Series option Communication unit Connection cable option Used to connect the BHT and host computer Software BHT BASIC 4 0 Development Pack Option and BHT BASIC 4 0 Transfer Utility Option Host computer BHT CU option 1 Connector communication 2 IrDA communication BHT BASIC 4 0 Transfer Utility Option BHT BASIC 4 0 Developmen...

Страница 15: ...st computer CU 601 RS 232C interface CU 611 Ethernet CU 621 USB interface Connection Cable Option or Commercially Available Product Used to connect the host computer and CU 600 Series Select a cable suited to the CU 600 Series interface being used Supported CU 600 Series Cables CU 601 RS 232C cable Option CU 611 Ethernet 10BASE T cable commercially available product CU 621 USB cable Option Further...

Страница 16: ... create handy terminal programs with BHT BASIC BHT BASIC4 0 Development Pack option This is a package containing four software products required for BHT Series application development and accessories The BHT BASIC 4 0 Development Pack contains the following products BHT BASIC 4 0 Compiler Compiles and links a source program written in BHT BASIC 4 0 to create a user program executable on the BHT PD...

Страница 17: ...tor interface has not been designed for frequent removal and insertion of the cable The CU 600 Series should normally be used Refer to Chapter 5 Communication 5 1 Connector Communication RS 232C Interface for details on the connector interface BHT BASIC4 0 Transfer Utility Option This is the same BHT BASIC 4 0 Transfer Utility that comes bundled with the BHT BASIC 4 0 Development Pack ...

Страница 18: ...ia drivers System Mode This program is used to operate files make system environment settings and perform various types of tests Refer to Chapter 4 System Operation 4 4 System Mode for further details Font File These files are required to display JIS 1 and 2 standard Kanji characters at the BHT unit LCD display By using font files the BHT unit is able to display 16 to 40 dot Kanji in application p...

Страница 19: ...haracter strings can be assigned at user programs Refer to Chapter 4 System Operation for details on how to operate the SYSTEM MENU 5 IrDA interface port Used to exchange data programs with the communication unit CU 600 or other BHTs 6 Hand strap Wear this strap around your wrist to prevent you from dropping the BHT accidentally 7 Battery cover Remove this cover to replace the battery cartridge 8 ...

Страница 20: ...c key M6 Each of the M3 and M4 keys is assigned a trigger switch by default The M5 key is assigned the C key by default Character strings can be assigned at user programs The SF ENT Backlight MENU or C key functions can be assigned with SYSTEM MENU A character or character strings can also be assigned with the user programs Hold down the M1 key to display the following setting screens when set to ...

Страница 21: ...rations 10 Function key Used to select functions 11 Power key Turns ON or OFF 12 Backspace key Removes the last character that you entered 13 Clear key Cancels entry and returns the LCD display to the previous screen 14 Shift key Used in combination with other keys such as the numerical keys for special input procedures ...

Страница 22: ...tatus When the SF and the BS keys are pressed while set to alphabet entry mode at the user program the entry mode changes from numeric entry to alphabet entry and displays Alphabet entry is used when performing FTP settings Refer to Chapter 7 2 1 Numeric Alphabet Entry of Programmer s manual for more information displays when a link is established with the CU 611 When an attempt is made to perform...

Страница 23: ...ading and Charging the Battery Cartridge 12 2 2 1 Battery Power Level Indicator 18 2 3 Attaching the Hand Strap 19 2 3 1 Attaching the Hand Strap 19 2 3 2 Holding the BHT 19 2 4 Initial Setup 20 2 5 Turning OFF the Power 21 2 5 1 Normal Power OFF 21 2 5 2 Turning the Power OFF after Data Back up 21 2 5 3 Auto Power OFF 21 2 5 4 If the BHT Is Shut Down Abnormally 22 2 5 5 If Invalid Files Are Found...

Страница 24: ...nd CH 704 are chargers to separately charge the battery cartridge on its own while the CH 651 and CH 654 are stationary models same type as CU communication unit for directly charging the battery cartridge placed in the BHT The charging time is approximately 3 hours The charging time is approximately 7 hours using the CU 621 with power supplied via the USB port This time will be reduced for a batt...

Страница 25: ...ridge terminals and indication on the BHT unit and then insert the cartridge in the direction indicated by the arrow Terminal Point Do not use battery cartridges other than those specified by DENSO WAVE 3 Insert the battery cover tab 1 and then close the battery cover 2 to lock the cover in position 4 Connect the dedicated AC adapter to the DC input connector on the charger and plug the adapter in...

Страница 26: ...t least 10 minutes when using the BHT for the first time or when using after long periods of time 6 The BHT indicator LED will change to green when charging is complete The BHT indicator LED will change to green when charging is complete Green LED ON Point The charge time is approximately 3 hours The charge time is approximately 7 hours using the CU 621 with power supplied via the USB port An only...

Страница 27: ...slightly discharged battery cartridge should take this time to become fully charged Take proper steps if the LED is blinking in red a Detecting the abnormal temperature of the battery cartridge Charge at the right temperature 0 to 40 degree Avoid the direct sunlight or something hot Stop the charging if under the proper environment b Bad electrical contact Wipe any dirt from battery cartridge term...

Страница 28: ...carry or store the battery cartridge together with metallic necklaces hairpins and so on Never expose the battery cartridge to fire or apply heat Never use or leave the battery cartridge in the vicinity of high temperature locations 60 C or higher such as a fire or stove Never place the battery cartridge into or soak it in water or seawater Never charge the battery cartridge in the vicinity of fir...

Страница 29: ...ry is fully charged do not remove the battery cartridge for at least 10 minutes when using the BHT for the first time or when using after long periods of time If you leave the BHT without a battery cartridge inserted for a long time the memory contents will no longer be backed up so that the message Contact your administrator Note the error number XXXX or Set the current date and time may appear o...

Страница 30: ...ss the ENT key The Battery Voltage screen displays while the keys are pressed About the Battery Level The battery power level indicator does not accurately reflect the battery residual power and should only be used as a guideline The battery power level will fluctuate due to BHT operation and therefore disparities may occur between the actual battery voltage and the display indicator Ensure to cha...

Страница 31: ...p Wear the hand strap to prevent the BHT from being accidentally dropped during use 2 3 1 Attaching the Hand Strap Attach the hand strap to the BHT as shown below 2 3 2 Holding the BHT Wear the hand strap to your wrist and hold the BHT as shown below or ...

Страница 32: ... date and time using the numeric keys Ex September 4 2010 14 20 Point Enter the last two digits for the year and enter the time in 24 hour clock format 3 Press the ENT key to set the date and time The screen right displays when the date and time are set 4 Press the numeric key 1 and the ENT key Then select 1 Yes A scanning demo commences The scanning demo is a program that allows codes to be read ...

Страница 33: ...n the power is next turned ON there are times when a message 2XXX displays asking the user to contact the administrator 2 5 2 Turning the Power OFF after Data Back up 1 Hold down the Power key for at least 3 seconds The message right displays and data back up is commenced The power turns OFF itself when the back up is complete Point Do not remove the battery cartridge while the message on the righ...

Страница 34: ...Normally shut down refers to 2 5 Turning OFF the Power 1 The right message will appear when you insert a charged battery cartridge and turn the BHT on 2 Press the 2 key while holding down the SF key The screen right displays 1 Yes Run Scandisk and start the System 2 No Turn the BHT off 3 Choose 1 Yes with the numerical keys and press the ENT key When Scandisk is in progress the right message is di...

Страница 35: ... enabled the screen given right may appear The BHT displays the screen for three seconds and then automatically runs the execution program from the beginning The screen may also appear when the calendar clock built in the BHT stops even without running Scandisk Point The resume function is used to return the display to the status screen when the power was last turned OFF when the power is next tur...

Страница 36: ...records numbered 1000 to 1200 is lost Ex SAMPLE1 DAT 01000 01050 If more than one sequence of records is broken in a same file SAMPLE1 DAT 01200 01250 they will be written into the subsequent records in the SAMPLE1 DAT 01600 01650 BRKLST SYS SAMPLE2 DAT 00250 00275 SAMPLE3 DAT 00100 00150 2 5 5 If Invalid Files Are Found Even invalid files can be uploaded so upload them to the host computer accord...

Страница 37: ...try and item selection using the BHT basic changes to settings and BHT data transmission 3 1 Reading Barcodes or 2D Codes 26 3 2 Numeric Data Entry 28 3 3 Task Selection 28 3 4 Changing the Default Settings 29 3 4 1 Procedure 29 3 5 Transmitting Data 31 3 5 1 Connector Communication 32 3 5 2 IrDA Communication 33 ...

Страница 38: ...e marker When the BHT has read the code successfully the indicator LED will illuminate in blue Point The code reading method may differ depending on the application Select the most appropriate in accordance with in the User s Manual Blue LED ON Note If required clean dirty labels before reading It may not be possible to perform reading in direct sunlight If the code is on a curved surface flatten ...

Страница 39: ...range is approx 6 4 cm if the reading distance is 11 cm Code surface curvature The code may not be read if surface is extremely curved Flatten the label surface and read it again Code surface dirt The code may not be read if its surface is dirty Wipe the dirt from the code and try again Code reading window dirt The code may not be read if the barcode reading window is dirty Blow any dust away with...

Страница 40: ...keys 1 2 and 0 followed by the Enter key 3 3 Task Selection If a selection item such as 1 XXX 2 XXX with numeric values displays enter the values with the numeric entry keys and then press the Enter key When Selecting Task 2 XXX Key Operation Press numeric key 2 followed by the Enter key If a YES NO selection screen such as 1 YES 2 NO displays press numeric key 1 to select YES and 2 to select NO W...

Страница 41: ...that notifies the user when code reading is complete ON OFF BRIGHTNESS Used to set the backlight brightness of the LCD screen The brightness can be adjusted in 5 levels Levels 1 to 5 BRIGHTNESS PS Used to set the backlight brightness of the LCD screen during power save mode The brightness can be adjusted in 6 levels Levels 0 to 5 POWER SAVE Used to set the time until the LCD screen backlight is di...

Страница 42: ...elected item is highlighted With BUZZER VOLUME highlighted press or with POWER SAVE highlighted press to change to the next screen 3 Use the and cursor keys to select the setting 4 Press any of the following keys to exit the settings screen M1 key long press Clear key Enter key ...

Страница 43: ...ion method and BHT setting method will differ depending on the system used and therefore the system administrator should be contacted for details of operation Requests Data gathered by the BHT should be promptly uploaded to the host computer IrDA Communication Connector Communication IrDA Communication CU 601 CU 621 CU 611 Dedicated interface cable CU 621 USB CU 611 Ethernet CU 601 RS232C Host com...

Страница 44: ...ated interface cable Requests Do not use a cable other than the dedicated interface cable Avoid disconnecting and reconnecting the cable more than once a day Disconnecting and reconnecting the cable too frequently will shorten the lifetime of the connector interface port Use the communication unit CU 601 CU 621 or CU 611 when it is necessary to perform frequent communication between the host compu...

Страница 45: ... exposed to light interference from sources such as intense ambient lighting inverter driven fluorescent lighting in particular or direct sunlight This may result in communication failure When performing data communication with the host computer Data can be transmitted directly to the host computer if the computer is equipped with an IrDA communication port If the host computer is not equipped wit...

Страница 46: ...34 BHT 604Q ...

Страница 47: ... Program Function 42 4 3 4 Executing by Wake up 44 4 3 5 Executing by Remote Wake up 44 4 4 System Mode 45 4 4 1 Starting Up System Mode 45 4 4 2 System Mode Basic Operation 46 4 4 3 SYSTEM MENU Configuration 48 4 5 SYSTEM MENU 52 4 5 1 Executing User Programs EXECUTE PROGRAM Menu 52 4 5 2 Downloading Files DOWNLOAD Menu 53 4 5 3 Uploading Files UPLOAD Menu 56 4 5 4 Copying Files between 2 BHT Uni...

Страница 48: ...essage displays on the screen when the BHT is turned on Point By initializing the system all files in the user area are deleted and therefore all files that need to be backed up should be uploaded to the host computer and so on beforehand Refer to section 4 5 3 Uploading files UPLOAD menu for details of uploading The initialization procedure is described on the following pages Perform operation in...

Страница 49: ... Memory Area Selected for Initialization 2 To delete font files Press the 2 key while holding down the SF key The screen displays as shown on the right Next press the 2 key select 2 WHOLE USER AREA and press the ENT key The screen changes to the 4 1 2 Selecting the Message Version English or Japanese 1 USER AREA EXCEPT FONTS The user area is initialized without deleting file fonts 2 WHOLE USER ARE...

Страница 50: ... files from deletion When the screen displays as shown on the right select the item and press the ENT key Press the C key to return to the screen to select the area for initialization 1 Yes The system will be initialized without deleting font files 2 No Cancels system initialization and turns the BHT power OFF 2 To delete font files When the screen displays as shown on the right select the item an...

Страница 51: ...r administrator Note the error number XXXX message displays even although initialization has been completed initialize the BHT again Following initialization all programs and data files stored in the target memory area will be lost Download them again if necessary Refer to section 4 5 2 Downloading Files DOWNLOAD Menu for details of downloading Always set the calendar clock following initializatio...

Страница 52: ... http www qbdirect net BHT SYSTEM UPDATE Refer to section 4 5 14 Updating the System MODIFY MENU and update the BHT system Important In order to prevent the battery running low during the system update process perform the system update with the battery sufficiently charged or with the BHT placed in the CU 600 Series If the BHT power turns OFF due to a low battery and so on during the system update...

Страница 53: ...following Web site http www denso wave com CU 611 System Update Refer to section 4 5 14 Updating the System MODIFY MENU and update the CU 611 System The CU 611 LED flashes during CU 611 system update Important Never remove the BHT from the CU 611 or turn the BHT power OFF during the system update process If the BHT is removed from the CU 611 or the BHT power turned OFF during system update a syste...

Страница 54: ...on If no program has been selected at the SYSTEM MENU EXECUTE PROGRAM menu and the BHT power is turned ON control will switch to the directory management program and the first of the programs PD4 registered in the BHT will executed If the resume function has been set the BHT will resume from the position in the program that was stopped when the BHT power was last turned OFF If downloading multiple...

Страница 55: ...version In the above case the registration order does not change and therefore MAIN PD4 starts up by pressing the Power key SUBMAIN PD4 MAIN PD4 BBBBBBBB DAT AAAAAAAA DAT Directory info MAIN PD4 Upgrade ver SUBMAIN PD4 Upgrade ver Download MAIN PD4 SUBMAIN PD4 BBBBBBBB DAT AAAAAAAA DAT Directory info Example 2 When newly downloading USER PD4 after deleting BBBBBBBB DAT In the above case USER PD4 i...

Страница 56: ...gram executed If an auto start execution program has been selected at the system Mode 4 5 5 1 Setting the auto start execution program the selected program will be executed If no auto start execution program has been selected the first registered program from among the programs PD4 registered in the BHT will be executed Refer to the BHT BASIC Programmer s Manual for details 4 3 5 Executing by Remo...

Страница 57: ...ote wake up setting System message file download upload System update Refer to each item at the 4 5 SYSTEM MENU for details of the above operations 4 4 1 Starting Up System Mode Use the following procedure to start up System Mode 1 Press the Power key while holding down the SF and 1 keys System Mode starts up and the SYSTEM MENU screen on right displays Select and display each menu from the SYSTEM...

Страница 58: ...EXECUTE PROGRAM will be highlighted when System Mode is started up 2 Press the ENT key The selected item is set and the next screen displays Press the C key to return to the previous screen The selected item will be highlighted when returning to the previous screen 3 Repeat the above operation to display the target menu Operation example ENT key ENT key ENT key C key C key Select 3 COM PORT with t...

Страница 59: ...key corresponding to the item to be selected Alternatively press the cursor keys to select the item The selected item will be highlighted 2 Select the setting value with the cursor keys 3 Press the ENT key The selected setting value will be set Select the setting item with the 2 key or keys Select the setting value with the cursor keys ENT key ...

Страница 60: ...n Select the item with the numerical keys or cursor keys and press the ENT key SYSTEM MENU Exeucting Programs Refer to section 4 5 1 Executing User Programs C key 1 and ENT keys 2 and ENT keys 3 and ENT keys Uploading Refer to section 4 5 3 Uploading Files Refer to section 4 5 2 Downloading Files Downloading ...

Страница 61: ...ironment Setting 5 and ENT keys 6 and ENT keys 7 and ENT keys 4 and ENT keys C key Testing Refer to section 4 5 6 BHT Operation Test System Information Display Refer to section 4 5 7 System Information Downloading Uploading by FTP Refer to section 4 5 8 Downloading Uploading Files by FTP ...

Страница 62: ... SYSTEM MENU Deleting Program Data Files Refer to section 4 5 9 Deleting Program Data Files 0 with SF held down 2 with SF held down C key 3 with SF held down Refer to section 4 5 11 Downloading Uploading the BHT System Parameter File Downloading Uploading the BHT System Parameter File Refer to section 4 5 10 Deleting Font Files Deleting Font Files ...

Страница 63: ...Wake up Refer to section 4 5 12 Setting Remote Wake up Downloading Uploading the System Message File C key Refer to section 4 5 13 Downloading Uploading System the Message File Updating the System Refer to section 4 5 14 Updating the System held down Dot with SF held down ...

Страница 64: ...key to return to the SYSTEM MENU 2 Use the cursor keys to select the target program The selected program will be highlighted Use the key to scroll down when more than 18 programs have been downloaded to the user area The screen on the right shows an example in which 23 programs have been downloaded 3 When the target program is highlighted press the ENT key The selected program will be executed The...

Страница 65: ...ownload order Refer to 4 3 Executing User Programs for details Use the following procedure to download files 1 Select 2 DOWNLOAD at the SYSTEM MENU and then press the ENT key The screen displays as shown on the right 1 FILE Select to download a specific file 2 HT HT COPY Select to download a file from another BHT Refer to 4 5 4 Copying Files between 2 BHT Units for details Press the C key to retur...

Страница 66: ...ing the BHT BASIC 4 0 Transfer Utility or similar program the screen displays as shown on the right and file downloading is commenced Refer to the BHT BASIC4 0 Transfer Utility User s Guide 4 The screen displays as shown on the right during downloading The screen displays as shown on the right indicating the file name and the number of received records the total number of records When using the Ym...

Страница 67: ...received file size equals the total file size Press the C key to return to the DOWNLOAD menu With this screen is displayed on the BHT downloading another new file from the host computer allows the BHT to begin receiving Refer to the BHT BASIC 4 0 Transfer Utility User s Guide If 2 HT HT COPY is selected repeat the above operation until all files are downloaded If an error message screen below disp...

Страница 68: ...Interface used Communication protocol type Ymodem BHT Ir BHTp Ymodem protocol BHT Ir protocol BHT protocol Interface used Opt Con Infrared interface Connector interface Copy speed 300 to 460800 Transmission speed corresponding to each protocol Refer to 4 5 5 System Environment Settings SET SYSTEM Menu for details of communication environment settings Point If BHT protocol or BHT Ir protocol is sel...

Страница 69: ...3 The screen displays as shown on the right If no files that can be uploaded exist in the user area Press the C key to return to the UPLOAD menu 3 The screen displays as shown on the right indicating that the BHT is waiting for the file to be uploaded The screen displays as shown on the right only when 1 FILE is selected If 2 ALL FILES is selected ALL displays in the center of the second row of th...

Страница 70: ...rotocol the sent file size the total file size units KB displays Press the C key to abort the download process and return to the UPLOAD menu 6 When uploading is complete the beeper sounds once and the screen screen displays as shown on the right When the number of sent records equals the total number of records downloading is complete When using the Ymodem protocol the sent file size equals the to...

Страница 71: ...ication ensure that the BHT infrared communication ports are facing one another When using the connector interface open the BHT connector covers and connect both BHT units using a cable with JC 25 P 3 2 5mm stereo mini plug Refer to Chapter 8 Specifications for cable details 4 Select 2 DOWNLOAD 2 HT HT COPY at the SYSTEM MENU of the BHT that is downloading to await downloading Refer to 4 5 2 Downl...

Страница 72: ... 7 Interface port to be used in user programs Interface port to be used in System Mode Communication parameters for the infrared interface Communication parameters for the direct connect interface Communication protocol options for the infrared interface Communication protocol options for the direct connect interface Communication protocol type Shift key function definition M1 key function definit...

Страница 73: ...tervals Timeout period for echo request No of echo requests to be sent Echo Request send timing TCP IP operation device TCP IP link layer Transmission speed between BHT and CU No of retries for link establishment command to be sent Link establishment command intervals No of retries for link release command to be sent Link release command intervals Link release period Service Set ID SSID Not possib...

Страница 74: ...te and time 4 QRCODE Sets the code reading conditions black white inverted label rading function inverted 2D code reading function decode label added option data for the 2D codes minimum number of read digits for read codes ITF Codabar light and sensor off time 5 COMMUNICATION Sets the communication environment interface port and communication parameters 6 KEY Defines the functions of the shift ke...

Страница 75: ...een displays as shown on the right The highlighted program will be the program currently set as the auto start execution program 2 Use the cursor keys to highlight the target program 3 Press the ENT key The selected program will be set as the auto start execution program Press the C key to return to the SET SYSTEM menu The screen screen displays as shown on the right if no programs have been downl...

Страница 76: ...T SYSTEM menu 1 MESSAGE Sets whether messages displayed at the screen are displayed in English or Japanese The default is the message version selected at the system initializing process The English and Japanese display changes at the following messages System error messages Indications relating to the LCD contrast Beeper volume Beeper vibrator switching Battery voltage level screens 2 STATUS Sets ...

Страница 77: ... Sets compatible mode for screen display between the BHT 100 and BHT 7500 This allows BHT 100 Series and BHT 7500 Series application programs to be used at the BHT 604Q without changing or correcting the font size BHT 604Q BHT 7500 BHT 100 BHT 7500 Mode BHT 100 Mode Normal Mode Standard font 26 x 20 char 6 x 8 dots 16 x 25 char 12 x 12 dots 26 x 26 char 9 x 12 dots 20 x 26 char 12 x 12 dots 20 x 2...

Страница 78: ...numeric entry mode to alphabet entry mode Displays when a communication link is established with the CU 611 Flashes when the BHT tries to communicate with a CU 611 that has not been linked with the BHT Communication link with the CU 611 Displays cyclically when the BHT receives no response from the CU 611 or when it is waiting for the link to be established with or severed from the CU 611 3 Settin...

Страница 79: ...s and minimum number of digits for the code to be read 1 Use the cursor keys or numerical keys 1 2 3 4 5 6 to highlight the item to be set highlight the setting value using the cursor keys and press the ENT key Press the C key to return to the SET CODE SCANNING CONDITIONS menu 1 INVERT Black white inverted label reading function Inverted 2D codes and barcodes can be read 0 Disables black white inv...

Страница 80: ... change these settings unless necessary Option data formats QR code N 1 N 2 N 3 N 4 N 5 N 6 N 7 1 2 3 N 1 N Q Model Version Error correcting level Mask Ex When read code is QR code Model 2 Version 5 Error correcting level M Mask number 6 Reading data Q2v05M6 PDF417 Readng data Option data Reading data Option data N 1 N 2 N 3 N 4 N 5 N 6 N 7 N 8 1 2 3 N 1 N Y Model Error correcting level Lines Digi...

Страница 81: ...t highlight the setting value using the cursor keys and press the ENT key Press the C key to return to the SET CODE SCANNING CONDITIONS menu 1 SCAN MODE Set the scan mode 0 Normal mode Codes within the field of view can be read Refer to Chapter 8 Specifications regarding the size of the field of view 1 Point scan mode Codes above the cross at the center of the marker can be read Reading will be un...

Страница 82: ...ironment settings following system initialization are follows Do not change these settings unless necessary Item Default Interface used Optical infrared interface port Communication protocol type Ymodem protocol Infrared interface port TRANSMIT SPEED Baud rate 115200 Bps PROTOCOL Protocol options SERIAL No ON Adds serial numbers to data blocks H PARITY ON Adds horizontal parity LINKUP TIME 30 seco...

Страница 83: ...he following section for details of the above items Press the C key to return to the SET SYSTEM menu 1 OPTICAL infrared communication parameters 1 Select 1 OPTICAL at the SET COMMUNICATION menu and then press the ENT key The SET OPTICAL menu screen displays as shown on the right 2 Use the cursor keys or numerical keys 1 2 to highlight 1 PARAMETER or 2 PROTOCOL and then press the ENT key Press the ...

Страница 84: ...t length in seconds to be applied when a link is to be established 4 FIELD SPACE Specifies handling for trailing spaces in fields To trim trailing spaces in fields select ignore and to retain them as data select data To change the setting use the cursor keys or numerical keys 1 2 3 4 to highlight the item to be set highlight the setting value using the cursor keys and then press the ENT key Press ...

Страница 85: ...ght The highlighted settings will be the current settings 1 TRANSMIT SPEED Sets the transmission speed 2 PARITY BIT Sets the vertical parity none odd or even 3 DATA BIT Sets the character length 4 STOP BIT Sets the stop bit length To change the setting use the cursor keys or numerical keys 1 2 3 4 to highlight the item to be set highlight the setting value using the cursor keys and then press the ...

Страница 86: ...ength in seconds to be applied when a link is to be established 4 FIELD SPACE Specifies the handling for trailing spaces in fields To trim trailing spaces in fields select Ignore and to retain them as data select Data To change the setting use the cursor keys or numerical keys 1 2 3 4 to highlight the item to be set highlight the setting value using the cursor keys and then press the ENT key Press...

Страница 87: ...r programs written in BHT BASIC OPEN COM Optical Uses infrared communication Connector Uses connector communication 2 SYSTEM MODE Selects the infrared communication Optical or connector communication Connector interface port to be used for downloading or uploading files in System Mode Optical Uses infrared communication Connector Uses connector communication To change the setting use the cursor ke...

Страница 88: ...XFILE statement in BHT BASIC 2 BHT Protocol Selects the BHT protocol when uploading downloading in System Mode or for the execution of the XFILE statement in BHT BASIC 3 BHT IR Protocol Selects the BHT IR protocol when uploading downloading in System Mode or for the execution of the XFILE statement in BHT BASIC To make changes use the cursor Keys or numerical keys 1 2 3 to highlight the setting it...

Страница 89: ...transfer None should normally be selected To add the BHT ID number to the transfer tool select Add This setting is not supported Changing this setting has no result 4 INTERVAL Specifies the retry interval within a range of 1 to 255 in units of 100 ms To change the setting use the cursor keys or numerical keys 1 2 3 4 to highlight the item to be set highlight the setting value using the cursor keys...

Страница 90: ...s no need to edit the current setting press the ENT key only Point ID numbers should consist of a five digit decimal character string The entry range is from 00001 To 65534 If the entry value is less than five digits the ENT key will be invalid If an incorrect entry is made press the BS key to delete it and then enter the correct data Press the C key to return to the SET COMMUNICATION menu ...

Страница 91: ...er switch key definition screen 6 M5 KEY Displays the M5 key definition screen 7 M6 KEY Displays the M6 key definition screen Refer to the following section for details of the above items Press the C key to return to the SET COMMUNICATION menu 1 SHIFT KEY Defining the Shift key function 1 Select 1 SHIFT KEY at the SET KEY menu and then press the ENT key The SET SHIFT KEY menu screen displays as sh...

Страница 92: ...een will return to the SET KEY menu Magic keys M1 to M6 Magic keys M1 to M6 can be set to function as the trigger switch SF key ENT key backlight function ON OFF key MENU key or C key If the M1 key is defined as the backlight function ON OFF key pressing the M1 key enables or disables the backlight function In user programs data strings can be also assigned to these Magic keys Magic keys M3 and M4...

Страница 93: ...resume function Note The resume function is used to return the BHT status screen when the power is turned ON to the status at the point the power was turned OFF 8 Defragmenting the drive Use the following procedure to defragment the drive 1 Select 8 DEFRAG at the SET SYSTEM menu and then press the ENT key The screen displays as shown on the right and the defragmentation process is performed for th...

Страница 94: ...lowing section for details of the above items Press the C key to return to the SET SYSTEM menu 1 SET TCP IP Setting the TCP IP 1 Select 1 SET TCP IP at the SET TCP IP menu and then press the ENT key The SET TCP IP menu screen displays as shown on the right 2 Use the cursor keys or numerical keys 1 2 to highlight the item to be set and then press the ENT key Press the C key to return to the SET TCP...

Страница 95: ...ENT key 3 If the IP address subnet mask and default gateway are all set to 0 0 0 0 DHCP is enabled Press the C key to return to the SET TCP IP menu 3 TIMEOUT Setting the timeout only when COM1 selected Select 3 TIMEOUT at the SET TCP IP menu to display the screen on the right where the current settings are displayed To change the setting 1 Use the cursor keys or numerical keys 1 2 3 4 5 to highlig...

Страница 96: ...3 PASSWORD Sets the password 4 DEFAULT DIR Specifies an initial directory through which the FTP server will search for files for transfer first when the FTP client establishes a connection to the server To change the setting 1 Use the cursor keys or numerical keys 1 2 3 4 to highlight the item to be set and press the ENT key 2 The mode changes to entry mode and the cursor displays allowing the set...

Страница 97: ...ite Uploaded files will be written over the existing files Append Uploaded files will be appended to the existing files 5 VERBOSE MODE Specifies the command response display when using FTP ON Displays a message to the response number from the FTP server when the BHT FTP client outputs a message OFF Displays only messages output by the BHT FTP client Refer to FTP Download Upload Messages at section...

Страница 98: ...ther than 0 0 0 0 the DHCP does not display on the screen shown on the right Point C key SF key 1 TIMEOUT Sets the timeout for acquiring the IP configuration from the DHCP Server The entry range is from 00001 to 32767 seconds Up to 32767 seconds can be entered but in actual operation a maximum of 190 seconds is available since the number of retries and retry intervals are determined by the system ...

Страница 99: ...d write test 3 BEEPER Selects the beeper scale test 4 AGING Selects the aging test 5 LCD Selects the LCD and indicator indicator LED tests 6 FILE Selects the file checksum test 7 COMMUNICATION Selects the communication test 8 KEY VIBRATION Selects the key entry beeper and vibrator tests 9 PING Selects the PING test Refer to the following section for details of the above items Press the C key to re...

Страница 100: ...n Ensure that the code data and screen display match Press the C key to return to the TEST menu Code Type and Corresponding Characters Displayed on the Screen Code type ID characters QR Code Q QR Code Codes concatenated with unedited modes S PDF417 Y Maxicode X Data matrix Z EAN 13 JAN 13 UPC A A EAN 13 JAN 13 UPC A COMPOSITE A EAN 8 JAN 8 B EAN 8 JAN 8 COMPOSITE B UPC E C UPC E COMPOSITE C Interl...

Страница 101: ...es and reading is complete The reading data screen display will not be shown until after concatenated code reading is complete If QR codes other than concatenated codes are read during concatenated code reading those codes are displayed the concatenated code reading mode is cancelled and the read concatenated codes are discarded This also happens if the trigger switch is released or the interval b...

Страница 102: ...MAXICODE 5 BARCODE Enable disable BARCODE 6 COMPOSITE Enable disable Composite 7 Add on Enable disable Add on It is not possible to enable both Add on and Multiline 8 Multiline Enable disable Multiline When Multiline is enabled the screen displays as shown on the right and the reading code can be set for the Multiline code To change the setting use the cursor keys to highlight 1ST 2ND or 3RD and c...

Страница 103: ... to enable ON or disable OFF 1 QRCODE Selecting enable disable QRCODE reading and availability of the concatenation function 1 QR MODEL1 Enable disable QR code Model 1 2 QR MODEL2 Enable disable QR code Model 2 3 Micro QR Enable disable Micro QR 4 STR APPEND Select the availability of the QR code concatenation function For QR Codes there is a function where data is coded after being split into a m...

Страница 104: ...g concatenated code reading then concatenated code reading ends the read concatenated codes are discarded and the data for the last QR codes read is saved Point When the illuminating indicator LED is set to OFF in trigger switch operation Auto off mode Momentary mode and alternate or when the reading of the next concatenated code is not completed within approx 3 seconds in modes other than Auto of...

Страница 105: ...F417 2 Micropdf417 Enable disable Micropdf417 To change the setting use the cursor keys or numerical keys 1 2 to highlight the item to be set highlight the setting value using the cursor keys and then press the ENT key Press the C key to return to the detailed settings screen for the code reading test ...

Страница 106: ...sable CODE39 7 CODE93 Enable disable CODE93 8 CODE128 Enable disable CODE128 9 RSS Enable disable RSS To change the setting use the cursor keys or numerical keys 1 2 3 4 5 6 7 8 9 to highlight the item to be set highlight the setting value using the cursor keys and then press the ENT key Press the C key to return to the detailed settings screen for the code reading test There are no setting items ...

Страница 107: ...heck XXXXX Tested RAM capacity unit kilobytes YYYYY Total RAM capacity unit kilobytes If any error is detected the BHT beeps three times displays a message similar to that shown on the right and aborts the test ZZZZZZZZ Address where the error occurred AAAAAAAA Data to write BBBBBBBB Data read out the RAM Press the C key to return to the TEST menu Upon normal completion of the RAM test the BHT bee...

Страница 108: ...BHT OFF Scale Frequency Hz do 523 1046 2093 4186 re 587 1174 2349 mi 659 1318 2637 fa 698 1396 2793 sol 783 1567 3135 la 880 1760 3520 ti 987 1975 3951 4 Aging test Use the following procedure to perform an aging test 1 Select 4 AGING at the TEST menu and then press the ENT key The aging test begins and the current date and time display on the screen This test is intended for personnel responsible...

Страница 109: ...wn on the right The indicator LED is OFF at this time Press the C key to return to the TEST menu 2 Press the ENT key The entire screen turns black and the indicator LED illuminates in green Press the BS key to return to the previous screen Press the C key to return to the TEST menu 3 Press the ENT key The entire screen turns gray Press the BS key to return to the previous screen Press the C key to...

Страница 110: ...C key to return to the TEST menu 5 Press the ENT key The entire screen turns an even lighter shade of gray Press the BS key to return to the previous screen Press the C key to return to the TEST menu 6 Press the ENT key The entire screen turns white Press the BS key to return to the previous screen Press the C key to return to the TEST menu ...

Страница 111: ...o the TEST menu 8 Press the ENT key The entire screen turns green and at the same time the indicator LED turns green Press the BS key to return to the previous screen Press the C key to return to the TEST menu 9 Press the ENT key The entire screen turns blue and at the same time the indicator LED turns blue Press the BS key to return to the previous screen Press the C key to return to the TEST men...

Страница 112: ...T key A 1 dot thick frame displays around the screen Press the BS key to return to the previous screen Press the C key to return to the TEST menu 11 Press the ENT key The beeper sounds once and the display returns to the TEST menu ...

Страница 113: ...e right and If any of the files stored in the memory is defective an asterisk or plus sign is prefixed to the name of the defective file s Refer to About BRKLST SYS in 2 5 4 If the BHT is shut DOWN Abnormally for details on the asterisk and plus sign SIZE bbbbb Used memory size FREE yyyyy available memory size 2 Use the cursor keys to highlight a file If there are more than ten files the screen ca...

Страница 114: ...ails of the above items Press the C key to return to the TEST menu Infrared communication Test 1 Arrange two BHTs one as a master station and the other as a slave station to be tested with their IrDA interface ports facing each other as illustrated below This test involves transmitting data from the test BHT and the master BHT returning the data to the test BHT 2 Select 1 OPTICAL at the TEST COMMU...

Страница 115: ...e test the tested slave BHT beeps once and displays the screen on the right omatically returns to the TEST COMMUNICATION At the slave BHT to be tested select 1 SLAVE and at BHT select 2 MASTER Then press the ENT key The screen displays as shown on the right during the test and an infrared commu If s The meanings of the error codes in p X X 1 The received data is different from the sent data 2 A ti...

Страница 116: ...eived data is different from the sent data e C key to return to the TEST COMMUNICATION menu pon normal completion of the test the BHT beeps once and displays the creen on the right ress the C key to return to the TEST COMMUNICATION menu Wire the cable with JC 25 P 3 2 5mm stereo mini BHT connector communication port Select 2 p T right The meanings of the error codes in parentheses are as follows X...

Страница 117: ... screen and the frequencies Hz of the beeper Key L test Pressing individual k pre assigned to those keys on the LCD as well as sounding the beeper or activating the vibrator As long as the individual key is held down the c P T R U m Turn OFF the power to abort the test during testing The table below shows the relationship between the keys th le etter Beeper Hz Key Letter Beeper Hz M1 1567 P RA1 22...

Страница 118: ...quests displayed enter the desired value sing the numerical keys 2 Press T key When the PING test starts running the message shown lays sh on the right Press key to rt NG te The TE 1 RUN PING Runs the PING test 3 SET DEVICE Dis Refer to the following section for details of the above items Press the C key to return to the TEST menu 1 RUN PING PING Test Scre 1 Select 1 RUN PING at the TEST PING menu...

Страница 119: ...the PING test Displays the BHT IP address during the PING test only IP e M ssages displayed during PING test display Waiting Setting up the PING test Opening device Opening devices Routing TCP IP Connecting to the TCP IP communication pathway t pen a device TCP IP error Failed to connect to the TCP IP communication pathway ermination messages displayed at bottom of screen PING start Starting the P...

Страница 120: ...2 SET PING PING Options Setting Screen S E The current settings are displayed 1 DESTINATION IP Specifies the IP address of the host computer to be pinged E Specifies the data size of the echo request 3 4 TIMEOUT Specifies th t period in units of 100 ms COUNT Specifies the number of echo requests to be sent Selects the ec Refer to PING Echo Request Transmission Timing SEND TYPE on the fol 2 Use the...

Страница 121: ...ly to be received or for a timeout to occur relationship between the INTERVAL and TIMEOUT is required If a timeout occurs TYPE1 request again For TYPE 1 the INTERVAL YPE2 Following that PING waits for the period specified at INTERVAL and then sends the next PING echo request For TYPE 2 no Sends an echo request Receives an echo reply Timeout period Interval Sends an echo request If PING receives an...

Страница 122: ...SET DEVICE at the TEST PING menu and then press the ENT ress the C key to return to the TEST PING menu 3 SET DEVICE PING Device Setting Screen S key The TCP IP communication device link layer and transmission speed display P ...

Страница 123: ...RMATION screen to display a license list as shown on the right The license list displays the names of functions for which licenses are required 1 symbol Indicates that a license has been registered 2 symbol Indicates that no license has been registered Even if functions for which licenses are required are loaded in the system these functions do not display in the list if they have never been run P...

Страница 124: ...he LICENSE INFORMATION screen Use the cursor keys to highlight the name of a function th that shown on the right containing the license registration details PRODUCT I PRODUCT NAME Product name PRODUCT KEY Product key Press the C key to return to the LICENS functions for which licenses have not been regi U n re PRODUCT ID PRODUCT NAME Product name PRODUCT KEY Product ke Press the e ter the product ...

Страница 125: ...N screen C Use the following procedure to display CU 611 System info 1 Place the BHT on the CU 611 Select 6 VERSION at the SYSTEM MENU and then press e ENT key e SYSTEM INFORMATION screen d ess the M2 key e CU INFORMATION screen display MAC ADDRESS MAC address Press the M1 key to return to the SYSTEM INFORMATION screen If the M2 key is pressed when the BHT is not on the CU 611 the displays as show...

Страница 126: ...e SYSTEM MENU 1 D wnloading by FTP OAD at the FTP MENU and then press the ENT key he screen displays as shown on the right nd or file name FIELDS Specifies field information for data files message indicating the status displays at the bottom of the screen screen on the right URRENT DIRECTORY Acquired current directory ress the M1 key to return to the previous screen 1 The FTP MENU DOWNLOAD Downloa...

Страница 127: ...s the ENT key P D The FTP client will interpret a character string entered into this box as a directory ll therefore send a Change Directory request to the FTP server If the specified directory exists in the FTP server the server will change a directory from the default to the specified one if nd send a Download request erver name at first and wi not the FTP client will interpret the entered chara...

Страница 128: ... the C key to delete all entries made When 2 SELECT FILE is Selected The screen displays as shown on the right Use the cursor Keys to highlight the upload file and then press the ENT key Return to the previous screen to display the selected file name in 2 FIELDS 1 Select 2 UPLOAD at the FTP MENU and then press the ENT key The screen displays as shown on the right If upload files exist 1 DIR FILE E...

Страница 129: ...string in the DIR FILE entry box the FTP client will pload to the server with the SELECT FILE entry box file name ELECT FILE entry box name at first and ectory exists in the FTP server the server will change a directory from the de to If the SELECT FILE entry box file name differs from the file name spec F If u S For uploading it is necessary to select a file to be uploaded to display the name ame...

Страница 130: ...r of files in the ploading Uploading starts pload failed Uploading has ended abnormally pload finished Uploading has ended normally of the screen Aborted Uploading or downloadin C D Downloading Downloading starts Download failed Downloading has ended abnormally Download finished Downloading has ended normally File broken The file being uploaded is corrupt File not found File not selected No file h...

Страница 131: ...g aborted 553 Requested action not taken The messages that FTP servers send during and after FTP operations vary but servers all use the same reply codes as listed belo 110 R re ly 120 Service re a prox nnn minutes 125 Data h s been established Start 150 File st e tablishing data conne 200 Comman 202 No respons th command Not required at this site 211 Syste or ystem help reply 212 Directo 213 File...

Страница 132: ...ogram Data Files D lete program files or data fi e the following procedure to delete files ess the 0 key while ENU holding down the SF key at the SYSTEM e DELETE FILE menu screen displays as s ess the C key to return e the cursor keys ess the ENT key e screen displays as shown on the right delete files e the cursor keys o d then press the ENT key e selected file is deleted and the screen displays ...

Страница 133: ...Uploading Files UPLOAD menu for details of uploading Use the following procedure to delete font files 1 ress the 2 key while holding down the SF key at the SYSTEM MENU he DELETE FILE menu screen displays as shown on the right ress the C key to return to the SYSTEM MENU 2 3 he screen displays as shown on the right If there is insufficient user area by deleting font files a user a size of the delete...

Страница 134: ...ey 2 to highlight 2 No and en press the ENT key ress the C key to return to the SYSTEM MENU then press the ENT key The selected file is deleted and the screen displays as shown on the right Press the C key t To cancel Use the cursor keys th The screen returns to the DELETE FILE menu The screen displays as shown on the right if no files exist P ...

Страница 135: ...em parameter file based on the current setting values and upload it to the host computer and on After uploading delete the created system parameter file ownloading the System Parameter File eceive the system parameter file from the host computer and so on to which it was backed up and after etting the stored values delete the received system parameter file The communication parameters communicatio...

Страница 136: ...ht indicating that the BHT is waiting for the system parameter file to be downloaded 2 While the download is in progress the screen right indicating the file name and the number of received records the total number of records P PARAMETER menu Upon completion of downloading the BHT displays the screen shown on the right and beeps once Press the C key to return to the SYSTEM PARAMETER menu e beeper ...

Страница 137: ... screen displays as shown on the right indicating the file name and the number of sent records the total number of records Press the C key to abort the upload and return to the SYSTEM PARAMETER menu 3 Upon completion of uploading the BHT displays the screen shown on the right and beeps once Press the C key to return to the SYSTEM PARAMETER menu The beeper sounds three times if an error occurs duri...

Страница 138: ...he C key to return to the SYSTEM MENU 2 Use the cursor keys or numerical keys 1 2 to highlight the 3 the settings with the cursor keys and press the ENT key Use the following procedure to perform remote wake up settings Press the 4 key while holding down the SF key at the SYSTEM MENU The SET REMOTE WAKEUP menu displays as show 1 2 P item to be set Highlight Press the C key to return to the SYSTEM ...

Страница 139: ...set when the BHT is shipped from the factory and therefore operation at this menu is unnecessary SYSTEM MESSAGE Menu such as shutdown in progress Do not remove the battery or Charge th ttery gs and upload it to the host ownloading Uploading the System Message File D 1 Upload the system me 2 Download the uploaded system mess U Create a system message file based on the curre Downloading setting the ...

Страница 140: ...le named _B60MSG FN3 in the user area An error will therefore occur if there is insufficient space in the user area to create the temporary file The created temporary file will automatically be deleted afte DOWNLOAD and then press the ENT key The screen displays as shown on the right indicating that the BHT is waiting fo 2 While the download is in progress the screen dis indicating the file name a...

Страница 141: ... BHT displays the screen shown on the PARAMETER menu he beeper sounds three times if an error occurs during uploading and an r Messages 7 2 System Mode Errors and Point When uploading the system message file the BHT creates a tically be deleted afte Press the C key to abort the upload and return to the SYSTEM MESSAGE menu right and beeps once Press the C key to return to the SYSTEM T error screen ...

Страница 142: ... using the procedure on the following page DO IT Updates the BHT system e to be used for updating the BHT system 2 ss the ENT key he screen shown displays as shown on the right and the BHT system is pdated pon completion of the update the BHT power turns OFF automatically stem MODIFY MENU Use the following procedure to update the system Press the dot key while holding down the SF key at the SYSTEM...

Страница 143: ...set the entered file name e BHT System te file does not exist when updating the BHT system again be used for updating the system enter the correct f 1 Use the cursor keys or numerical key 2 to highlight 2 FILENA E and then press the ENT dance display and alphabet T Use the numerical keys and dot key to enter the c Press the SF and the BS key to change the entry mode num entry a s T P P If the Syst...

Страница 144: ...e 1 Use the cursor keys or numerical key 2 to highlight 2 FILENAME and then press the ENT key The mode changes to entry mode and the cursor displays 2 Use the numerical keys and dot key to enter the correct file name Press the SF and the BS key to change the entry mode numeric entry with no guidance display and alphabet entry To delete a single character press the BS key Press the C key to delete ...

Страница 145: ...ating the CU 611 system ODIFY menu the CU 611 System Update Fails he screen displays as shown on the right if the CU 611 system update Press the C key to return to the CU F W MODIFY menu The screen displays as shown on the right if the system update file does not exist when updating the CU 611 system again Press the C key to return to the CU F W MODIFY menu If T Set the BHT on the CU 611 and try a...

Страница 146: ...134 BHT 604Q ...

Страница 147: ...5 1 Connector Interface RS 232C Interface 136 5 1 1 Interface Connector and Pin Assignment 136 5 1 2 Interface Cable Connection 137 5 2 Infrared Communication 138 5 2 1 Infrared Communication Port Transmission Speed 139 5 2 2 BHT Hardware Physical Layer and Communication Protocols 139 5 3 Basic Communication Specifications and Parameters 140 5 3 1 Basic Communication Specifications 140 5 3 2 Commu...

Страница 148: ...ive data Signal ground Signal Voltage Input Output Level Signal Input Voltage Threshold RD Output Voltage Threshold SD 0 1 3V min 3V max 5V min 5V max Note The BHT connector port is not designed for frequent cable insertion and removal Repeatedly inserting and removing the cable more than once a day will result in a shortening of the connector port lifetime and therefore IrDA communication CU 600 ...

Страница 149: ...t the BHT directly to a host computer a modem or a printer with a connector interface cable as illustrated below Ex 1 Cable Connection between BHT and Host computer Host computer Ex 2 Cable Connection between BHT and Modem Ex 3 Cable Connection between BHT and Printer ...

Страница 150: ...ation speed Freedom from regulations and licenses that differ from country to country when using wireless devices Communication is performed by arranging the BHT and other IrDA compliant devices with their IrDA infrared interface ports facing one another The communication distance and angle and so on will differ depending on the devices used Refer to the instructions given in the manuals provided ...

Страница 151: ... 2 460 8kbps CU 611 4Mbps 5 2 2 BHT Hardware Physical Layer and Communication Protocols BHT Hardware Physical Layer Except Baud Rate 460 8 kbps The BHT complies with IrDA Ver1 3 Low Power physical layer compliant by IrDA Infrared Data Association The maximum transmission distance is 0 15 m BHT Communication Protocols Max Baud Rate 115 2 kbps The BHT supports Ymodem BHT Ir protocol and BHT protocol...

Страница 152: ...inning and end of the character to be transmitted must be defined beforehand Start stop synchronization is an asynchronous system that synchronizes each character as a unit that is it externally adds start and stop bits to the leading and trailing bit positions of the character to be transmitted respectively Data sampling is commenced upon receiving the start bit and when the stop bit is received ...

Страница 153: ...bit Start bit Vertical parity A vertical parity bit is a redundant bit that is added to every character transmitted in order to check that data has been transmitted accurately The parity bit should be set to either 1 or 0 depending upon the parity parameter setting to make the number of set bits in the character even or odd The receiver counts the number of set bits in the transmitted character co...

Страница 154: ...unication with the dedicated CU 611 unit System Mode Refer to Chapter 4 System Operation 4 4 3 SYSTEM MENU Configuration BHT BASIC To set the transmission speed character length vertical parity and stop bit length For the IrDA interface set the transmission speed only use the OPEN COM statement in BHT BASIC OPEN COM Opens the interface port selected in System Mode OPEN COM1 Opens the IrDA interfac...

Страница 155: ...r taking care of the BHT and CU CH 6 1 Replacing the Battery Cartridge 144 6 1 1 Battery Cartridge Service Life 144 6 1 2 Battery Cartridge Replacement Method 144 6 2 Using the BHT after Long Periods 146 6 3 Daily Maintenance 147 6 3 1 Proper Care of the BHT 147 6 3 2 Proper Care of the CU CH 147 ...

Страница 156: ...turn OFF the BHT power The screen displays as shown on the right Point Do not remove the battery cartridge until the power turns OFF itself and the message on the screen given to the right is cleared 2 Slide the battery lock 1 in the direction indicated by the arrow and remove the battery cover 2 and then remove the battery cartridge 3 3 Insert a new battery cartridge in the direction shown by the...

Страница 157: ...ease read the following items prior to use Never charge the battery cartridge in the vicinity of fire or under a scorching sun Always use a dedicated charger to charge the battery cartridge Mishandling may result in battery cartridge overheating smoke generation blowout or combustion Please read the following item prior to use Terminate charging if not completed even after the specified time has e...

Страница 158: ... at least 10 minutes No Can the power be turned ON Point Files may become corrupt if left for a long period of time without replacing the battery cartridge Does the normal screen display The BHT can be used Charge promptly before the battery becomes fully depleted The Set the current date and time screen displays The Contact your administrator screen displays Set the current date and time Refer to...

Страница 159: ...soapy water always use neutral detergent and wrung out thoroughly Any dirt or dust adhering to the red clear plate of the barcode reading window will adversely affect reading performance When using in dusty areas perform periodic inspections to check whether any dust has accumulated on the clear plate of the barcode reading window and if so clean the plate as described below First blow the dust aw...

Страница 160: ...148 BHT 604Q ...

Страница 161: ...s causes and countermeasures for error messages that display during BHT use About error messages during executing application program refer to Appendix A Error Codes and Error Messages of Programmer s manual 7 1 System Errors 150 7 2 System Mode Errors 154 ...

Страница 162: ...tem Program error has occurred Contact your system administrator If low battery is detected the BHT beeps three times After that it will resume previous regular operation The battery output level has dropped below a specified lower limit Replace or recharge the battery cartridge If this error occurs the BHT beeps five times and then turns itself off Depending upon the battery level the beeper may ...

Страница 163: ...nues to display After shut down abnormally the BHT has been left without the battery cartridge loaded or with discharged battery cartridge loaded so unsaved data was lost Contact your system administrator If this error occurs the BHT beeps five times During execution of System Program the System Program has attempted to write onto the write protected area of the memory xxxxxxxx Error address Unloa...

Страница 164: ...ministrator The message continues to display When the BHT is turned on no user programs are found Contact your system administrator You can run the code scanning demo without user programs Pressing 1 Yes runs the code scanning demo Press the trigger switch to start the code scanning demo Selecting 2 No turns the power off If this error occurs the BHT beeps five times and then turns itself off Any ...

Страница 165: ... your system administrator After displaying this error message the BHT may start a user program other than the preset auto start execution program or display the message No execution program loaded Your settings made in System Mode contain an error Contact your system administrator If this error occurs the System Mode settings revert to the factory defaults If this error occurs the BHT beeps five ...

Страница 166: ...mory is insufficient for storing files to be downloaded Press the 2 key to return to the SYSTEM MENU then delete unnecessary files in the memory or decrease the size of the file to be downloaded In the SYSTEM PARAMETER transfer menu you attempted to download a file other than the BHT system parameter file Or in the SYSTEM MESSAGE transfer menu you attempted to download a file other than the system...

Страница 167: ...e than one file in the DOWNLOAD menu Downloading has failed Uploading has failed To retry downloading uploading press the 1 key To return to the SYSTEM MENU press the 2 key Check the interface port communications parameters and communications protocol in the SET SYSTEM menu or perform the communications test in the TEST menu You attempted to download an invalid program file Check whether the progr...

Страница 168: ...fficient for setting up the BHT system parameter file or system message file to be uploaded Press the C key to return to the SYSTEM MENU and delete unnecessary files The memory has already contained 420 files so the BHT system parameter file or system message file cannot be set up Press the C key to return to the SYSTEM MENU and delete unnecessary files ...

Страница 169: ...ifications This chapter describes the BHT 604Q specifications 8 1 BHT 604Q Specifications 158 8 1 1 Hardware Specifications 158 8 1 2 Supported Code Types 159 8 1 3 Scanning Performance 161 8 1 4 Interface Specifications 163 ...

Страница 170: ...2 Display Type Dot matrix TFT liquid crystal display LCD with backlight Formation 240 dots wide by 320 dots high Display characters The following is an example Font size Chars x Lines Dots W x H 40 dot font Full width Half width 6 x 8 12 x 8 40 x 40 20 x 40 30 dot font Full width Half width 8 x 10 16 x 10 30 x 30 15 x 30 24 dot font Full width Half width 10 x 13 20 x 13 24 x 24 12 x 24 16 dot font...

Страница 171: ... 1 to 9 digits 3 to 41 lines 1 0 25 mm min 1 Does not include start stop codes and left right indicator Micro PDF417 Digits lines Module dimensions 1 to 4 digits 4 to 44 lines 2 0 25 mm min 2 Does not include left middle and right Row address pattern MaxiCode Module size Module pitch 30 29 modules 33 modules 0 88 mm Data Matrix Code size Cell pitch Max 96 cells 96 cells 360 skew 0 25 mm Max 88 cel...

Страница 172: ... values all apply to ambient illuminance of 500 to 3 000 Lx xenon lamp light source Multiline codes Multiline reading can be performed up to a maximum of 3 lines at a time in the specified order on the following codes Universal product codes Interleaved 2of5 ITF Codabar NW 7 Code 39 Code93 Code 128 EAN 128 This can only be specified with application programs Refer to BHT BASIC Programming Manual B...

Страница 173: ...n As illustrated at left align the reading window with the center of the label code to be scanned Reading Performance Scanning reference position 105 mm Label Field of view at each distance W x H QR code cell pitch dimensions and valid scanning range Barcode valid scanning range ...

Страница 174: ...ing level M Black white label Barcode module dimensions Valid reading distance 0 15 mm 0 25 mm 0 33 mm 60 to 125 mm 3 50 to 215 mm 4 50 to 275 mm 5 PCS value 0 9 min White reflection intensity 85 min 3 Under the following conditions Codabar 10 digits NarrowBar NarrowSpace 0 15mm 4 Under the following conditions Codabar 10 digits NarrowBar NarrowSpace 0 25mm 5 Under the following conditions EAN 8 M...

Страница 175: ...ible when communicating from one BHT 600 unit to another or with the CU 621 4 Mbps is only possible for communication with the dedicated CU 611 unit The maximum transmission speed in all other cases is 115 200 bps Connector Interface Synchronization Start stop Transmission speed Max 115 200 bps Signal level Conforms to the RS 232C interface Pin assignment As shown below SD RD GND Pin No Signal Nam...

Страница 176: ...164 BHT 604Q ...

Страница 177: ...ons and describes causes and countermeasures when unable to transfer files 9 1 CU 600 SPECIFICATIONS 166 9 1 1 Hardware Specifications 166 9 1 2 Charging Requirements CU 601 611 621 166 9 1 3 Interface Specifications 167 9 2 When File Transfer is Not Possible Using the Transfer Utility 169 ...

Страница 178: ...n 6 5 VA 7 VA 5V 500 mA Dimensions W x L x H 110 x 134 x 81 7 mm Weight 105 g 110 g 100 g Ambient operating temperature 0 to 40 C Ambient operating humidity 20 to 80 with no dew condensation The CU 621 can be powered also from the AC adapter 9 1 2 Charging Requirements CU 601 611 621 Charge current Approx 950 mA approx 400 mA Charging time Approx 3 hours approx 7 hours When the CU 621 is powered f...

Страница 179: ...tor uses Dsub 9P Pin No Signal Name Function Signal Direction CU 601 External Device 2 RD Receipt data 3 SD Transmission data 4 ER Data terminal ready 5 SG Signal ground 6 DR Data set ready 7 RS Transmission request 8 CS Transmission ready Ref The CU 601 internal wiring is shown below BHT 604QW CU 601 ...

Страница 180: ...erface Port RJ45 jack on the CU 611 Pin No Signal Functions 1 TD Send data 2 TD Send data 3 RD Receive data 4 N C No connection 5 N C No connection 6 RD Receive data 7 N C No connection 8 N C No connection CU 621 The USB interface on the CU 621 is USB1 1 Full speed compliant with a Type Mini B receptacle ...

Страница 181: ...switch on the reverse side of the CU Defect or abnormality with the USB cable between the PC and CU Use a properly functioning USB cable Unstable signal wire due to such reasons as a USB cable extension Connect directly to a PC USB port or self powered hub Connection may not be possible depending on the hub model and if operation is unstable connect directly to a PC USB port The CU can be removed ...

Страница 182: ...s not possible to download a file with the same name but different field width from the file already existing in the BHT Either delete the existing data file in the BHT or specify the same field format as the existing data file 55 71 Illegal characters have been used in the file name Change the file name Refer to QBdirect page 171 Note 1 for details of characters that can be used in file names 75 ...

Страница 183: ...te 1 Customer Registration is required to use QBdirect free of charge When using for the first time complete Customer Registration and then refer to the following procedure to use QBdirect Refer to Customer Registration on page ii 1 Click the QBdirect URL below 2 Enter your user ID and password to log in 3 Search what you need to enter keyword to the textbox http www qbdirect net ...

Страница 184: ...2D Code Handy Terminal BHT 604Q User s Manual First Edition Oct 2008 Second Edition Mar 2010 ...

Отзывы: