160
BHT-604Q
Barcodes
Supported Barcode Types
Bar Dimensions
Scan Magnification
Universal product codes
EAN-13 (JAN-13)
0.26 to 0.50 mm
0.8 to 1.5 times
EAN-8 (JAN-8)
0.26 to 0.66 mm
0.8 to 2.0 times
UPC-A
0.26 to 0.50 mm
0.8 to 1.5 times
UPC-E
0.26 to 0.66 mm
0.8 to 2.0 times
Interleaved 2of5 (ITF)
2 to 46 digits
*
Codabar (NW-7)
3 to 30 digits
Code 39
1 to 24 digits
Code 128
(
EAN-128
)
1 to 19 digits
RSS-14 (GS1 DataBar)
Min. 0.15 mm
14 digits
* Even number digits only
Note: These specification values all apply to ambient illuminance of 500 to 3,000 Lx.
(xenon lamp light source)
Multiline codes
Multiline reading can be performed up to a maximum of 3 lines at a time in the specified order on the
following codes: Universal product codes, Interleaved 2of5 (ITF), Codabar (NW-7), Code 39, Code93,
Code 128 (EAN-128).
This can only be specified with application programs. Refer to BHT-BASIC Programming Manual (BHT
Series).
Required Optical Properties
White bars: Reflection intensity of 45% or higher
Black bars: Reflection intensity of 25% or lower
PCS value of 0.45 or higher
The reflection intensity is regulated with a light source with spectral peak of 650 nm and spectrum
range of 610 to 700 nm.