Ping echo request transmission timing
Two types of echo request transmission timing are available: Type 1 and
Type 2. (Default: Type 2)
Type1
Type 1 sets the interval for a definite period of time between ping echo
requests regardless of the timeout occurrence.
Set the interval time greater than or equal to the timeout time (Interval
Timeout), when Type 1 is chosen.
Type2
Type 2 sets the interval after receiving the ping echo reply and after timeout occurs.
The interval time and timeout time do not affect each other in Type 2.
Ping echo request
Ping echo reply
Timeout time
Interval time
Ping echo request
Ping echo request
Timeout time
Timeout occurs
Ping echo request
Interval time
Ping echo request
Ping echo reply
Ping echo request
Interval time
<When the ping echo reply is received>
<When the timeout occurs>