3.6. Protection History Display Mode
3.6.1. Actions
This mode records and displays an event in which the THERMAL, CURRENT, ASO or DC protection was activated.
If protections have been activated multiple times, the latest protection operation is recorded.
3.6.2. Starting up
Hold down buttons "
STATUS
" and "
ZONE3 SOURCE
" at the same time and press the power button to turn on the power.
Select the "
2. PROTECTION
" using the button "
CURSOR
f
", and press the button "
ENTER
" to commit the selection.
3.6.3. Protection information and displays
·Press the "
STATUS
" button in Protection History Display Mode.
·The protection history can be checked.
(a) If no protections have occurred.
FLD
L1
P R O T E C T
H I S T O R Y
L2
: N O
P R O T E C T
(b) ASO (if the last protection was ASO)
FLD
L2
: A S O
Cause :
A short circuit occurred between the speaker terminals, or speakers with an impedance outside the rating
wereconnected.
If the power is turned on during this abnormality, protection is activated after around 6 seconds and the power is turned off.
(c) DC (if the last protection was DC)
FLD
L2
: D C
Cause :
DC output of the power amplifier is abnormal.
If the power is turned on during this abnormality, protection is activated after around 6 seconds and the power is turned off.
(d) THERMAL (if the last protection was THERMAL(E) or THERMAL(F))
FLD
L2
: T H E R M A L
E
FLD
L2
: T H E R M A L
F
Cause :
Abnormal heat sink temperature.
If the power is turned on during this abnormality, protection is activated after around 6 seconds and the power is turned off.
(e) Case of CURRENT (when the last protection incident was CURRENT protection)
FLD
L2
: C U R R E N T
Caution
:
These protections may also be activated due to causes such as disconnection of connectors or operations
around the microcomputer.
If the power is turned on during this abnormality, protection is activated after around 2 minutes and the power is turned off.
After viewing the above protection history, press the button "
STATUS
" to return to the normal display.
71
Содержание AVR-X7200W
Страница 8: ...Personal notes 8 ...
Страница 204: ...MX25L1606EM2I 12G DIGITAL U102 U202 U302 U402 MX25L1606EM2I 12G Block Diagram 8 PIN SOP 200mil 150mil BLOCK DIAGRAM 204 ...
Страница 210: ...NJW1194A INPUT U3203 U3204 BLOCK DIAGRAM 210 ...
Страница 211: ...2 FL DISPLAY FLD 17 BT 40GINK FRONT SPK Z6801 PIN CONNECTION GRID ASSIGNMENT Y2 q 211 ...
Страница 212: ...ANODE CONNECTION 212 ...