ADJUSTMENT
Adjusting Idling Current
1. Preparation
(1) Prepare a DC voltmeter.
(2) Place the unit under normal usage conditions, away from highly ventilated areas such as next to an air conditioning
machine or electric fan.
The set requires an ambient temperature of 15℃ to 30℃ and standard humidity.。
(3) Settings of This Unit
• POWER (Power source switch)
STANDBY
• SPEAKER (Speaker terminal) No load
(Do not connect equipment such as speakers or dummy resistors.)
2. Adjustment Procedure
(1) Remove the top cover and turn VR550, VR540, VR530, VR520, VR510, VR570, VR560 of the AMP PCB counterclock-
wise(
c
) as far as possible.
(2) Connect the DC Voltmeter to the test points.
FRONT-Lch
: CN510
FRONT-Rch
: CN550
CENTER ch
: CN530
SURROUND-Lch
: CN520
SURROUND-Rch
: CN540
SURROUND-BACK Lch
: CN560
SURROUND-BACK Rch
: CN570
(3) Connect the power cord to an outlet. Next, press the power button to turn on the power.
(4) Set this unit as follows.
MASTER VOLUME
: "---" (
c
min.) : turn counterclockwise to the lowest position.
SPEAKER (Speaker terminal)
: No load
(Do not connect equipment such as speakers or dummy resistors.)
MODE
: MCH STEREO
FUNCTION
: DVD
(5) Turn VR550 clockwise (
x
) and adjust the voltage of the test point to "
1.5mV ± 0.5mV DC
" within 2 minutes.
(6) 10 minutes after the preliminary adjustment, turn VR550 and set the voltage to "
2.0mV ± 0.5mV DC
".
(7) Adjust the variable resistance of each channel using the same method.
F Rch
S Rch
C Rch
S Lch
F Lch
S Back Rch
S Back Lch
VR550
VR540
VR530
VR520
VR510
VR570
VR560
SBR
SBL
SL
SR
CEN
FL
FR
CN550
CN540
CN530
CN520
CN510
CN570
CN560
DC Voltmeter
AMP UNIT
70
Содержание AVR-S710W
Страница 8: ...8 Personal notes ...
Страница 144: ...NJU72340AFH3 DIGITAL_ANALOG IC821 NJU72340A Terminal Functions 144 ...
Страница 147: ...2 FL DISPLAY FLD 018BT021GINK FRONT FL101 PIN CONNECTION GRID ASSIGNMENT 147 ...
Страница 148: ...ANODE CONNECTION 148 ...
Страница 168: ...EXPLODED REF No Part No Part Name Remarks Q ty New Ver S14 nsp SCREW CTW3 6JR VTW3 6JR 2 20 ...