background image

Aquascaping

Scaper‘s Flow

Hang-on external filter for aquascaping aquariums, 30 – 120 l

- Please read all instructions carefully before turning the equipment on. Save these instructions for future reference. -

Congratulations on purchasing this high-end Dennerle product. We wish you years of enjoyment and pleasure with your aquarium!

1 Security notes

• For use with 230 V/50 Hz alternating current only.
• For indoor use only.
• Always disconnect all equipment in the water from the power supply before reaching into the aquarium.
• The mains plug must be permanently accessible once the device is in place.
• All cables leading from the aquarium, including the power cables for the equipment, must have a drip loop attached so that any 
  water running down cannot reach the equipment and/or the mains outlet.
• The equipment must not be used if the power cord is damaged. Damaged power cords must not be replaced.
• This equipment is not intended to be used by persons (including children) with limited physical, sensory, or mental capacity, lack of 
  experience, and/or lack of knowledge, unless said persons are supervised for their own safety by another responsible person or are given 
  instructions by this person on how to use the equipment. Children must be supervised to ensure that they do not play with the equipment.
• Magnetic fields can cause electronic or mechanical defects and damage to the equipment. This also applies to cardiac pacemakers. For 
  information about the requisite safe distances, please refer to the instruction manual for your medical device.
• To be used for the specified purpose only. The use of any additional parts not recommended by the equipment manufacturer can result in 
  unstable operation, for which the manufacturer offers no warranty.
• Permitted water and room temperature range: 10 - 35 °C
• Maximum pump head: 60 cm. Please position filters accordingly.
• Please install the entire filter before switching on. Fill the filtration chamber with water before switching on to ensure that the pump can 
  function correctly.
• Do not use the filter if the filter head gets hot or makes unusual noises.
• When you install the filter for the first time, leave it to run for 24 hours in a water circuit (e.g., a separate aquarium or bucket) before adding fish, 
  to remove any residues potentially left over from the production process.

t

2 Component names and components included

No.  Name 

 

Total number

   

 

Filter

1  

Filter bowl 

 

1

2  

Filter head with pump and seal 

1

3  

Stoppers with seal for water filler opening 

1

4  

Power cord 

 

1

   

 

Add-on components

5  

Suction pipe, split 

 

1

6  

Suction pipe, extension 

 

1

7  

Intake protection (filter sponge) 

1

8  

Corner piece with 2 O-rings  

2

9  

Corner piece, elastic, 55 x 30 mm 

2

10  Screwcap 

 

6

11  Tube connector 

 

1

12  Corner piece, elastic, 22 x 30 mm 

1

13  Lily pipe 

 

1

14  Filter holder 

 

2

15  Pipe holder, left 

 

1

16  Pipe holder, right 

 

1

17  Cover plate for filter holder   

2

18  Spacer incl. rubber 

 

1

   

 

Filter basket and filter materials 

19  Filter basket 

 

2

20  Pre-filter sponge 

 

1

21  Fine filter pad filled with active charcoal 

1

22  Bio filter tubes 

 

1

23  Cover for filter basket 

 

1

   

 

Accessories for running a standing filter, 

   

 

with 12/16 mm tubes (not included) 

 

24  90° tube guide 

 

2

25  Tube holder (for 5mm thick glass) 

2

8

20

21

22

23

24

25

Содержание Scaper's Flow

Страница 1: ...Aquascaping Scaper s Flow D Gebrauchsanleitung 1 F Notice d emploi 5 t Operating instructions 8 I Istruzioni per l uso 11 Gebruiksaanwijzing 14 2 4 5 6 8 8 9...

Страница 2: ...erheitsabst nde sind den Handb chern dieser medizinischen Ger te zu entnehmen Nur f r den angegebenen Verwendungszweck Die Verwendung von Anbauteilen die nicht vom Ger tehersteller empfohlen werden ka...

Страница 3: ...e ca 2 3 untergetaucht Der pl tschernde Wasserr cklauf sorgt in dieser Position f r schnelle Sauerstoffzufuhr Wichtig als Soforthilfe bei Sauerstoffmangel erkennbar an schneller Atmung der Fische Veru...

Страница 4: ...e und Zubeh r 5605 Impeller 5609 Achse f r Impeller 5606 Dichtung f r Filterkopf 5603 Bio FilterTubes 500 ml 5604 Filterschwamm 5607 Nano FilterPad Feinfilter Pad mit Aktivkohle F llung 5793 Lily Pipe...

Страница 5: ...cessaires se r f rer aux manuels de ces appareils m dicaux Cet appareil est exclusivement destin l usage indiqu L utilisation d l ments rapport s non recommand s par le fabricant de l appareil peut co...

Страница 6: ...la respiration rapide des poissons Les impuret s la surface de l eau voile mycodermique descendent dans l eau sous l effet des remous avant d tre limin es par filtration Conseil suspendre le filtre e...

Страница 7: ...Lily Pipe 5794 Joints toriques jeu pour pi ces coud es 4 pi ces 5795 Tube d aspiration jeu tube d aspiration fente tube d aspiration rallonge 5796 Porte filtres jeu 2 x porte filtre porte tube gauche...

Страница 8: ...manual for your medical device To be used for the specified purpose only The use of any additional parts not recommended by the equipment manufacturer can result in unstable operation for which the m...

Страница 9: ...mergency measure if there is a lack of oxygen as indicated by fish breathing faster Vortices are formed that drag surface residues film under water which are then filtered out Tip Hang the filter in t...

Страница 10: ...ngs set for corner piece 4 pieces 5795 Suction pipe set split suction pipe suction pipe extension 5796 Holders set 2 x filter holders pipe holder left pipe holder right 2 x tube holder 2 x cover plate...

Страница 11: ...di questi dispositivi medici Solo per lo scopo di utilizzo previsto L utilizzo di pezzi non raccomandati dal produttore del dispositivo pu comportare condizioni di funzionamento non sicure nessuna gar...

Страница 12: ...scibile dalla respirazione accelerata dei pesci Le contaminazioni sulla superficie dell acqua fioretta vengono trascinate sott acqua grazie alla formazione di vortici e quindi filtrate Consiglio appen...

Страница 13: ...per gomiti rigidi 4 pezzi 5795 Set di tubi di aspirazione tubo di aspirazione fessurato prolunga tubo di aspirazione 5796 Set di supporti 2 supporti filtro supporto tubo a sinistra supporto tubo a des...

Страница 14: ...veiligheidsafstanden zijn te vinden in de handleidingen van deze apparatuur Alleen bestemd voor het aangegeven gebruiksdoel Het gebruik van uitbreidingsonderdelen die niet door de producent worden aa...

Страница 15: ...ontreinigingen op het wateroppervlak waas worden door werveling onder water getrokken en er vervolgens uitgefilterd Tip Het filter overdag in de onderste positie hangen s nachts in de bovenste Zo word...

Страница 16: ...e kool 5793 Lily Pipe 5794 O ringen set voor hoekstukken 4 stuks 5795 Aanzuigbuis set aanzuigbuis met sleuven aanzuigbuis verlengstuk 5796 Houder set 2 x filterhouder buishouder links buishouder recht...

Отзывы: