8.5. HTTP/XML/JSON Settings
Figure 8.7.
HTTP/XML/JSON Settings
These settings let you configure the HTTP, XML and JSON access parameters of
smartDEN IP-16R-XX:
HTTP Port:
Port that the Web server listens for HTTP requests (default port is
80). You have to reboot the device for a new port setting to apply;
Access IP Address/Access Mask:
These fields can be used to restrict the
HTTP/XML/JSON access by specifying the IP address and subnet mask of the
HTTP client;
Access MAC Address:
This field can be used to restrict the
HTTP/XML/JSON access by specifying the MAC address of the HTTP client;
Session Timeout, min:
Specifies the timeout period for HTTP, XML and
JSON sessions in minutes;
Enable Access:
This option enables or disables XML/JSON access to the
smartDEN IP-16R-XX
;
Encrypt Password:
When XML/JSON access is enabled, this option adds
additional security level by encrypting the login password;
Multiple Access:
This option enables simultaneous access from several
HTTP/JSON clients;
Save button:
Once you have changed the settings as required, click this
button.