4. Machine Spare Parts Lists
MERLION PLUS - E500
STD04
Page 40 of 50
Circuit Highlights:-
Standard circuit w/o Auto SS (Normal Operation):-
•
Terminal TB3&TB4(see Note 1) is shorted
•
Terminal TB2 & TB6(see Note 2) is Not Connected
Auto S.S Kit = Circuit w/Auto SS function:-
•
Disconnect bridging wire from Terminal TB3 &
TB4 (see Note 1)
•
Connect Terminal TB3 onto T1 (
Timer-700530514
)
of Terminal 16.
•
Connect Terminal TB4 onto T1, Terminal 15.
•
Connect Terminal TB6 onto T1 of Terminal A2.
•
Connect RED/RED Wires on the SW1 & SW2 onto
TB2
•
Connect Brown Wire of SW1 to Terminal
TB3,Terminal of T1, A1 & Y1
•
Connect Blue Wire of SW2 to Terminal TB5
•
Set on T1 , S1 = Function = Op
•
Set on T1 , S2 = Time = 2s
•
Set on T1, S3 = Range = 60s
•
Machine will stop after 2mins without trigger is
pressed
Main Contactor Overload Setting
The setting of the overload-LRD must be
always set at about 2x of the motor running
current at ~26A.
Incorrect setting of the overload will burnt the motor or
creates unnecessary tripping of the overload.
Motor Switch
Timer Setting
Star- Delta Timer Setting :
Factory setting of the switching of the motor from Star-Delta is set to 50ms. While the time to switch
over is 3s.
RANGE:-must be set to “
1s
” as shown.
TIME:-must be set to “
3
”
MS:- must be set to “
50
”
Содержание Merlion Plus E500
Страница 32: ...4 Machine Spare Parts Lists MERLION PLUS E500 STD04 Page 31 of 50 4E ii E500 Pump Spare Parts Repair Kit List ...
Страница 35: ...4 Machine Spare Parts Lists MERLION PLUS E500 STD04 Page 34 of 50 E500 Un loader Assembly ...
Страница 40: ...4 Machine Spare Parts Lists MERLION PLUS E500 STD04 Page 39 of 50 4F Electrical Assembly Wiring diagram ...