8. Commissioning
Operation and Installation Manual for SOLIVIA 10.0 / 11.0 EU G4 TR
36
➔
-------------------
continue
PDD: Standard
-------------------
PDD settings
9. Press the
buttons to select
continue
and then
press the button.
→ If the PDD setting is
User
, an extended
PDD Set-
tings
menu will be displayed. Continue with Step 10.
→ If the PDD setting is
Standard
or
Off
, the
Locked
Power Limit
menu will be displayed. Continue with
Step 12.
➔
continue
Umax: 253V
-------------------
PDD settings
10. To change the value, press the button and then set
the value using the
buttons. Press the button to
apply the value.
nOTE
: Steps 10 and 11 are only
necessary when the mode
User
was
set in Step 9.
Available Umax settings:
253 ... 264 V (corresponds to 110 -
115% of 230 V), default is 253 V.
➔
-------------------
continue
Umax: 253V
-------------------
PDD settings
11. Press the
buttons to select
continue
and then
press the button.
→ The
Locked power limit
menu is displayed.
➔
Smax: _._kVA
Pmax: _._kW
-------------------
Locked power limit
12. To change a value, press the button and then set the
value using the
buttons. Press the button to
apply the value.
nOTE
: If you change one of the val-
ues, you must fi ll out the provided
label after commissioning and place it
next to the type plate.
nOTE
: The confi gured values can
only be changed after commissioning
with a PIN.
nOTE
: The confi gured values are
displayed after commissioning in the
131 View Grid Setup menu.
➔
continue
Smax: _._kVA
Pmax: _._kW
-------------------
-------------------
Locked power limit
13. Press the
buttons to select
continue
and then
press the button.
→ The
Format
menu is displayed.
➔
Time: 24h
Date: DD.MM.YYYY
-------------------
Format
14. To change the value, press the button and then set
the value using the
buttons. Press the button to
apply the value.
Available date formats:
DD.MM.YYYY | DD/MM/YYYY
DD-MM-YYYY | MM.DD.YYYY
MM/DD/YYYY | MM-DD-YYYY
YYYY.MM.DD| YYYY/MM/DD
YYYY-MM-DD
Available time formats:
12h | 24h
➔
continue
Time: 24h
Date: 25.05.2012
-------------------
-------------------
Format
15. Press the
buttons to select
continue
and then
press the button.
→ The
Date and Time
menu is displayed.
➔
Time: 14:26:51
Date: 25.05.2012
-------------------
Date and time
16. To change the value, press the button and then set
the value using the
buttons. Press the button to
apply the value.
➔
continue
Time: 14:26:51
Date: 25.05.2012
-------------------
-------------------
Date and time
17. Press the
buttons to select
continue
and then
press the button.
→ The
RS485
menu is displayed.
Содержание SOL10.0-1TR3-E4
Страница 1: ...Operation and Installation Manual for SOL10 0 1TR3 E4 SOL11 0 1TR3 E4...
Страница 89: ......