Delta MultiChoice 17T Series Скачать руководство пользователя страница 8

Maintenance

Cannot receive more than a trickle of water:

Both hot and cold supply lines must be pressurized. 

If only one side is pressurized, the system will not 

allow adequate flow of water.

 

Faucet leaks from showerhead:

Remove the showerhead then turn the water on 

and off to verify if the cartridge is leaking or the 

showerhead is draining slowly (the showerhead may 

need to be cleaned if water drains slowly).

If leak persists -

SHUT OFF WATER SUPPLIES 

Replace cartridge assembly - RP47201.

Unable to set or maintain mixed water temperature:

 

SHUT OFF WATER SUPPLIES. Remove handle 

assembly, trim sleeve, and bonnet nut. Check to make 

sure the “H” marking on the cartridge aligns with the 

hot inlet and the “C” marking on the cartridge aligns 

with the cold inlet to the valve body The thermostatic 

cartridge cannot function if hot and cold inlets are 

reversed.

Low flow:

 

Low flow may be caused by clogged screens within 

the thermostatic cartridge. To clean the hot and cold 

screens in the cartridge, follow the steps below:

1. SHUT OFF WATER SUPPLIES.

2. Remove the handle assembly.

3. Unscrew the hex shaped portion of the cartridge 

    from the brass section of the cartridge. the brass  

    section must be held securely by the flats while 

    the hex is rotated counter-clockwise. Failure to 

    secure the brass section while rotating the         

    hex can result in damage to the cartridge.   

    (See illustration below)

4. Carefully clean any debris from the screens

    under running water. If the debris is difficult to

    remove then soak the screens overnight in a

    50% water and 50% vinegar solution.

5. Reassemble the cartridge.

6. Replace the handle.

7 Turn the water back on.

8. Reset the limit stop before using the valve.

8

Cartridge Summary Reference Sheet

Order RP47201 to 

Replace Cartridge.

Cleaning and Care

Care should be given to the cleaning of 

this product. Although its finish is extremely 

durable, it can be damaged by harsh 

abrasives or polish. To clean, simply wipe 

gently with a damp cloth and blot dry with a 

soft towel.

Warning:

 

Scrubbing Bubbles

®

 Bathroom

 

Cleaner and Lysol

®

 Basin Tub and Tile 

Cleaner

 must not be used on the clear knob 

handles and levers. Use of these cleaners 

can result in cracked or severely damaged 

handles. If overspray gets onto the handles, 

immediately wipe them dry with a soft cotton 

cloth.

Black

Brass

17T

68883  Rev. I

Hex shaped 

portion

Flats

Содержание MultiChoice 17T Series

Страница 1: ...are unsure how to properly make these adjustments please refer to page 7 and if still uncertain call us at 1 800 345 DELTA After installation and adjustment you must affix your name company name and t...

Страница 2: ...BE LIABLE FOR ANY SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING LABOR CHARGES FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ON THE FAUCET Some states provinces do not allow the exclusion or l...

Страница 3: ...emove from the valve body Insert cartridge into valve body as shown Ensure the keys on the body are fully engaged with the slots in the body 4 Slide bonnet nut 1 over the cartridge and thread onto the...

Страница 4: ...ee of burrs to prevent cutting or nicking O ring inside the spout Slide spout over copper tube flush with the finished tub or wall surface Tighten set screw 2 but do not overtighten Iron Pipe Installa...

Страница 5: ...d wall and all slack is taken up behind wall B 4 1 3 2 Iron Pipe Installation Installation of easy on universal tub spout Install pipe nipple so that end of nipple projects out from finished wall surf...

Страница 6: ...with lever to the right using an Allen wrench 2 to secure with the set screw 3 Secure the escutcheon 1 to the bracket 2 with the 2 screws provided 3 Do not overtighten escutcheon screws If you are ins...

Страница 7: ...ore than 120 or the lower temperature mandated by your local plumbing code If max temperature is not achieved before limit stop 3 on temperature knob 1 meets the limit stop 4 on the volume control han...

Страница 8: ...ly 3 Unscrew the hex shaped portion of the cartridge from the brass section of the cartridge the brass section must be held securely by the flats while the hex is rotated counter clockwise Failure to...

Страница 9: ...bios del agua de entrada son por los cambios estacionales ADVERTENCIA No instale un aparato de corte o cierre en cualquiera de las tomas de esta v lvula Cuando este tipo de aparato cierra el flujo de...

Страница 10: ...OS DE MANO DE OBRA POR EL INCUMPLIMIENTO DE CUALQUIER GARANT A EXPRESA O IMPL CITA DE LA LLAVE DE AGUA Algunos estados provincias no permiten la exclusi n o limitaci n de da os especiales incidentales...

Страница 11: ...ucho en el cuerpo de la v lvula como se muestra Aseg rese que las llaves en el cuerpo est n totalmente engranadas en las ranuras en el cuerpo 4 Deslice la tuerca tapa 1 sobre el cartucho y enrosque en...

Страница 12: ...prevenir cortar o mellar el aro O dentro del tubo de cobre Deslice el surtidor sobre el tubo de cobre al ras con la ba era o la superficie de la pared acabada Apriete el tornillo de ajuste 2 pero no...

Страница 13: ...tr s de la pared B 4 3 2 1 Instalaci n del tubo de hierro Instalaci n del tubo de salida de agua del easy on universal para ba eras Instale la entrerrosca del tubo de manera que el extremo de sta sobr...

Страница 14: ...de asegurar con el tornillo de presi n 3 Fije la roseta con orificio 1 al soporte 2 usando los 2 tornillos suministrados 3 No apriete demasiado los tornillos de la roseta Si est instalando the Cassidy...

Страница 15: ...atura 1 donde tropieza con el tope del l mite rotacional 4 en la manija del control de volumen Retire la perilla del control de temperatura 1 de las ranuras 2 Gire la perilla del control de temperatur...

Страница 16: ...de la manija 3 Desatornille la porci n en forma hexagonal del cartucho de la secci n de bronce del cartucho La secci n de bronce debe mantenerse fija por los cortados planos mientras que la secci n he...

Страница 17: ...du changement de saison MISE EN GARDE N installez pas de dispositif d arr t sur une sortie quelconque de ce robinet En interrompant l coulement de l eau ce dispositif peut emp cher le robinet d quili...

Страница 18: ...et au Mexique DELTA FAUCET COMPANY SE D GAGE DE TOUTE RESPONSABILIT L GARD DES DOMMAGES PARTICULIERS CONS CUTIFS OU INDIRECTS Y COMPRIS LES FRAIS DE MAIN D OEUVRE QUI POURRAIENT R SULTER DE LA VIOLATI...

Страница 19: ...sa d pose Introduisez la cartouche dans le corps de la soupape comme le montre la figure Assurez vous que les ergots sont parfaitement engag s dans les rainures du corps 4 Faites glisser l crou port...

Страница 20: ...es glisser le bec sur le tube de cuivre de sorte qu il s appuie contre la surface finie de la baignoire ou du mur Serrez la vis de calage 2 mais prenez garde de la serrer excessivement Installation l...

Страница 21: ...idement contre la surface finie de la paroi et qu il n y ait plus de jeu derri re le mur B 4 1 3 2 Installation sur un tuyau de fer Installation du bec de baignoire polyvalent easy on Installez le man...

Страница 22: ...s la droite utilisant une cl Allen 2 de fixer avec la vis de r glage 3 Fixez la rosace 1 sur le support 2 l aide des 2 vis fournies 3 Prenez garde de serrer les vis de la rosace excessivement Si vous...

Страница 23: ...as la temp rature maximale avant que la but e de temp rature maximale 3 sur le bouton de temp rature 1 n atteigne la but e de temp rature maximale 4 sur la manette de d bit retirez le bouton de r glag...

Страница 24: ...s tournez la partie hexagonale dans le sens antihoraire Si vous ne tenez pas la section en laiton assez solidement la cartouche risque d tre endommag e Voir l illustration ci dessous 4 Nettoyez soigne...

Страница 25: ...Notes Notas Notes...

Страница 26: ...Notes Notas Notes...

Страница 27: ...Notes Notas Notes...

Страница 28: ...Delta Faucet Company Product Service 55 E 111th Street Indianapolis IN 46280...

Отзывы: