Installation
2
Showerhead and Tub Spout Installation
5
Copper Sweat Installation
Remove O-ring (1) from adapter (2). Solder
adapter to tube taking care to keep solder away
from O-ring groove. CAUTION: NO SOLDER
PERMITTED ON OUTSIDE DIAMETER OF
ADAPTER ADJACENT TO O-RING GROOVE. Cut
off tube (3) and replace O-ring on groove of brass
adapter. Thread tub/spout onto adapter, taking
care not to damage O-ring, and hand tighten until
spout is firmly against finished wall and all slack is
taken up behind wall.
B-4
1
3
2
Iron Pipe Installation
Installation of easy-on universal tub spout
Install pipe nipple so that end of nipple projects out
from finished wall surface 1/2" to 1 1/4" (13 mm to
32 mm).
Apply plumber tape or pipe dope to pipe threads.
Hand tighten adapter (1) onto pipe nipple (2).
Finish tightening with standard pipe wrench until
a positive seal is implemented. Take care not
to damage O-Ring (3) groove. Back of adapter
(1) must not project more than 1" (25 mm) from
finished wall surface.
Hand tighten tub spout onto adapter (1) taking care
not to damage the O-Ring (3).
B-3
1/2" to 1 1/4"
(13 mm to 32 mm)
1
2
3