Load Cell Module DVP02LC-SL
DVP-PLC Operation Manual
C R # 2 2 , 23 , 2 4 , 2 5:
CH1 to CH2 unit of measurement
Explanations:
These control registers record the units of measurement in hex values corresponding to the ASCII
words set up by the user. Each channel is able to contain maximum 4 ASCII words.
ASCII/hex table:
Hex
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
ASCII
0 1 2 3 4 5 6 7 8 9
⌧
⌧
⌧
⌧
⌧
⌧
Hex
40
41
42
43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
ASCII
⌧
A B C D E F G H I J K L M N O
Hex
50
51
52
53
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
ASCII P Q R S T U V W X Y Z
⌧
⌧
⌧
⌧
⌧
Hex
60
61
62
63
64
65
66
67
68
69
6A
6B
6C
6D
6E
6F
ASCII
⌧
a b C d e f g h i j k l m n o
Hex
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
7F
ASCII
p q r s t u v w x y z
⌧
⌧
⌧
⌧
⌧
Example: If you would like the unit for CH1 to be “gram”, set up CR#22 and CR#23 following the
figure below.
67H
72H
61H 6DH
CR#22
CR#23
a
m
g
r
C R # 2 6 :
Weight correction command
Explanations:
Commands for the user to correct weights.
Value
Function
H’0001
CH1 reset to zero
H’0002
CH1 weight base point
H’0003
CH2 reset to zero
H’0004
CH2 weight base point
C R # 3 3 , 34 :
CH1 to CH2 weight base point
Explanations:
The weight of the weights has to be written in during the correction.