Load Cell Module DVP02LC-SL
DVP-PLC Operation Manual
100ms (10 × 10ms) and the range returns to be within 1,000, bit4 and bit5 of CR#50 will be set to 1
again. We recommend you check if the measured value is stable enough before controlling it.
t
k
m
>k
<k
>k
>k
>k
>k
>k
>k
<k <k
bit
△
>k
△
<k
△
>k
△
>k
△
>k
△
>k
△
>k
△
>k
△
<k
△
<k
△
m
t
Time
bit4 & bit5 of CR#50
Average weight
t: measuring time set up by user
k: range for standstill check set up by user
m: times of standstill checks set up by user
△
: change of average weight
Relevant control registers
y
CR#16,17: Times of standstill check
y
CR#18,19: Range for standstill check
5.3.3 Determining Zero Point
You can use the zero point determination function to know if the object has been removed from the load
cell. If the bit4 and bit5 of CR#50 are 1, and the bit0 and bit1 are 1 as well, the object has been
removed from the load cell already, and you will be able to perform the next step of the control.
DVP 02L C-SL
CH1
CH2
Load cell
No object to
be measured
Average weight
Time
Range for zero
point weight
Zero point weight
Relevant control registers
y
CR#37, 38, 39, 40: Upper/Lower limits for zero point check
5.3.4 Filtering
The average value is a steady value obtained from the sum of the read values. However, due to
unavoidable external factors, the read values may be an acute pulse, resulting in fierce changes in the