Installation should be in accordance with local plumbing and electrical codes.
FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION.
STEP 1. ROUGH IN
STEP 2. FAUCET INSTALLATION
Mount faucet to sink using the provided components in the following
order - grey bottom spacer, washer, lock nut (Fig. 9).
NOTE: The
black top spacer must be used at all times between the spout
and countertop/sink, and the grey spacer must be used at all
times between the washer and deck. Ensure open side of
bottom spacer faces up. Washer faces away from sink and
must not touch any conductive surfaces (metal sink, screws,
drainage).
If cover plate is being used, it must be between the top
spacer and the deck. Ensure that gasket is sitting inside groove of
top spacer. Use the same procedure for installation of optional 4”
or 8” deck plate package (061269A or 061270A). Mount the faucet
to the sink using nut(s) and washer(s) provided. Do not overtighten
the nut or reposition the faucet once installed, otherwise damage to
the gasket may result. Cutting or trimming of the gasket is not
recommended.
NOTE: If the gasket is trimmed or not installed,
then use clear silicone sealant between the faucet and lavatory
to prevent water from leaking beneath lavatory.
If recessed box is supplied, rough in as per Figure 8. The most
vandal resistant installation is when the control box is as close to
the bottom of the sink as feasible. For wall hung sink installation,
sensor conduit rough in should be directly under the basin to
minimize sensor cord exposure. Rough in drainage. Rough in
water supply to 10” control box inlets and to spout connection.
Finish walls.
Valve spacer is for temporary use only for flushing of system.
Must be replaced with solenoid and washers (Figure 8).
STEP 4a. CONNECT ELECTRICAL SUPPLY, SOLENOID VALVE
AND SENSOR
STEP 3. CONNECT WATER SUPPLY
Install sink and connect drainage to rough in. See Figure 8.
Polymer braided hose (supplied) must be connected to the spout.
Other connection tubes and fittings are supplied by the installer to connect to the 1/2” nominal
sweat at the box outlet. Connect water supply through to spout. Assure supply lines are
completely flushed and free of debris. Install aerator.
Product supplied
as shown by solid
lines. All items
shown by dotted
lines supplied by
others.
Typical Installation
(Recessed Mount Box)
Flexible
Sensor
Cord Conduit
Polymer
Braided Hose
257mm (10.13")
Control Box
305mm (12")
Stainless Steel
Cover Plate
102mm (4")
355mm
(14”) max.
Fig. 7
Remove valve spacer and install solenoid valve and washers with body arrow in the direction
of water flow. See Fig. 10. Feed sensor wire from spout into control box and then connect to
the driver board. Connect red solenoid wire from the driver board to “+” marked solenoid
terminal on solenoid valve, black solenoid wire to other solenoid terminal. Attach sensor
module to the faucet shank with the clip. See Fig. 11. Ensure the clip does not contact any
material other than the faucet shank. Connect the sensor cable to the controller board.
IMPORTANT: ENSURE THAT WATER SUPPLY IS ON BEFORE PROCEEDING. WHEN
POWER IS FIRST APPLIED TO THE DRIVER BOARD, THE INSTALLER MUST
IMMEDIATELY STEP BACK AT LEAST 3 FEET FROM THE PROXIMITY SPOUT IN ORDER
TO ALLOW THE UNIT TO PROPERLY CALIBRATE.
Open the control box. Install batteries provided into the battery holder.
Do not install 9V
battery.
Connect battery clip to battery pack and
step back at least 3 feet from the control
box and spout in order to allow for proper calibration.
5 quick beeps 3 times will be
generated when power is first applied to the unit. Do not secure the lid until after successfully
testing for operation (step 6).
1/2” Sweat
Outlet
Flexible Sensor Cord
Conduit (supplied on
Recessed Mount Box)
Control Box #1
Fig. 8
Tempered Water
(By Others)
Inlet:
1/2” Sweat
060671A
3/4” NPS
Solenoid
Valve &
Washers
061252A
Driver board
to be located
on this bracket
063135A
Stop
621TPxxx1TR Battery Operated Control Box #1 Trim
INSTALLATION AND SET UP INSTRUCTIONS
STEP 4b. CALIBRATION
After power is applied to the driver board, it generates 5 quick beeps 3 times which prompts
the installer to step away from the unit. During the calibration process, the water will turn ON
for several seconds then proceed to shut off. An additional 5 beeps indicates calibration is
complete and the faucet is ready to use. The cover should be secured at this time.