background image

Page 8

209989   Rev. B

Installation should be in accordance with local plumbing and electrical codes.

FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION. 

 

w w w . s p e c s e l e c t . c o m

620TPxxx0  Hard Wire Operated Surface Mount Box #0

Fig. 19

 

Top Spacer

& Gasket

Washer

Nut

Spout

Bottom Spacer

Sensor

Module

Fig. 20

Fig. 23

STEP 1. FAUCET INSTALLATION

STEP 3. FLUSH SYSTEM

To flush supply line, assemble the bypass adapter as shown (Fig. 21) and run water for one

minute.  Shut off water supply.  Attach aerator.  

NOTE:

 Do not connect supply to the solenoid 

inlet until the line is flushed directly out of the spout.

STEP 4. CONNECT WATER SUPPLY

Disassemble the components, reassemble the ones shown here (Fig. 22) supply line and adapter

to the bottom fitting on solenoid, polymer braided spout hose to the top fitting on solenoid.  Use

plumber tape where indicated on adapter.  Turn on water supply.  Must use polymer braided hose

on both the inlet and outlet of this solenoid.  

DO NOT SOLDER CONNECTIONS.

STEP 5. CONNECT PROXIMITY

®

 SENSOR

Run the sensor wire out of the battery box through the box openings around the solenoid.  Attach

the sensor module to the faucet shank with the clip.  Ensure the clip does not contact any

material other than the faucet shank (Fig. 23).

STEP 6. PREPARE SINK AREA

Before connecting the power - clean off counter and remove all objects from the sink.

STEP 7a. CONNECT POWER

IMPORTANT: ENSURE THAT WATER SUPPLY IS ON BEFORE PROCEEDING.  WHEN 

POWER IS FIRST APPLIED TO THE DRIVER BOARD, THE INSTALLER MUST IMMEDIATELY

STEP BACK AT LEAST 3 FEET FROM THE PROXIMITY SPOUT IN ORDER TO ALLOW THE

UNIT TO PROPERLY CALIBRATE.

Install CSA and/or UL approved Class 2 transformer or equivalent in a convenient and appropriate

location.  Do NOT install the transformer inside the control box.  Use 3-conductor 18 AWG wire

between the transformer and the control box.  With the power off, connect 

the 24VAC supply from the transformer to the pair of white supply wires 

coming from the hardwire converter.  Refer to Fig. 24 and Fig. 25 for 

reference wiring diagrams.  Install the grounding kit assembly (061259A)

per the supplied instruction sheet for proper grounding with Conductive and

Non-Conductive sinks.
Turn on power supply for the transformer.  5 quick beeps 3 times will be

generated when power is first applied to the unit.  At this stage, step back

at least 3 feet from the controller and spout in order to allow for proper 

calibration.  Do not secure the lid/cover until after calibration.    

Bypass

Adapter

Braided

Polymer

Hose

INSTALLATION AND SET UP INSTRUCTIONS

Fig. 21

Fig. 22

Mount faucet to sink using the provided components in the following order - grey bottom spacer,

washer, lock nut (Fig. 19).  

NOTE: The black top spacer must be used at all times between

the spout and countertop/sink, and the grey spacer must be used at all times between the

washer and deck.  Ensure open side of bottom spacer faces up. The faucet and shank

must not touch any conductive surfaces (metal sink, screws, drainage).  

If cover plate is

being used, it must be between the top spacer and the deck.  Ensure that gasket is sitting flat on

the deck and the faucet is centered on the gasket.  Use the same procedure for installation of

optional 4” or 8” deck plate  package (061269A or 061270A).  Mount the faucet to the sink using

nut(s) and washer(s) provided.  Do not overtighten the nut or reposition the faucet once installed,

otherwise damage to the gasket may result.  Cutting or trimming of the gasket is not recom-

mended.  

NOTE: If the gasket is trimmed or not installed, then use clear silicone sealant

between the faucet and lavatory to prevent water from leaking beneath lavatory.

Mount surface mount box to wall under sink using the 4 supplied screws and anchors.  Use 1/4” 

drill for wall anchors.  

Be sure to install the box within the dimensions and orientation

provided so the hose and sensor cable will reach connections at faucet and surface mount

box.  Refer to illustration (Fig. 20).

STEP 2. SURFACE MOUNT BOX INSTALLATION

7" (178 mm)

Max.

13" (331 mm)

Max.

 

Tie

Wraps

Threaded

Shank

Braided

Polymer

Hose

from

spout

Braided

Polymer

Hose

063131A

3/8” Comp

Connect

Nut & Ferrile

Plumber

Tape

Braided

Polymer

Hose

Содержание 62 TP3 Series

Страница 1: ...xx8TR Description Battery Operated Surface Mount Box 0 Battery Operated Control Box 1 Trim Battery Operated Control Box 8 Trim Hard Wire Operated Surface Mount Box 0 Hard Wire Operated Control Box 1 Trim Hard Wire Operated Control Box 8 Trim Page 2 4 6 8 10 12 COVER 060073A Screws 4 pkg and driver bit for covers 060577A 12 Stainless Steel Cover TMV Repair Kits 061137A Adjustment Wrench 063164A Che...

Страница 2: ... in accordance with local plumbing and electrical codes FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION Fig 3 w w w s p e c s e l e c t c o m 621TPxxx0 Battery Operated Surface Mount Box 0 Mount faucet to sink using the provided components in the following order grey bottom spacer washer lock nut Fig 1 NOTE The black top spacer must be used at all times between the spout and countertop sink and the...

Страница 3: ...tance the ability to store an electrical charge is brought on by a 2nd conductor a human body entering the Proximity field As the human hand enters and leaves the vicinity of the electrical field around the spout the solenoid is opened and closed accordingly It is critical in the installation process that all electrical and mechanical connections be as tight and rigid as possible ensuring a smooth...

Страница 4: ... at the box outlet Connect water supply through to spout Assure supply lines are completely flushed and free of debris Install aerator Product supplied as shown by solid lines All items shown by dotted lines supplied by others Typical Installation Recessed Mount Box Flexible Sensor Cord Conduit Polymer Braided Hose 257mm 10 13 Control Box 305mm 12 Stainless Steel Cover Plate 102mm 4 355mm 14 max F...

Страница 5: ...round a conductor the spout and monitoring the change in capacitance that the conductor undergoes The change in capaci tance the ability to store an electrical charge is brought on by a 2nd conductor a human body entering the Proximity field As the human hand enters and leaves the vicinity of the electrical field around the spout the solenoid is opened and closed accordingly It is critical in the ...

Страница 6: ... spacer is for temporary use only for flushing of system Must be replaced with solenoid and washers Figure 13 STEP 4 FLUSH SYSTEM SET TEMPERATURE Remove coverplate from control box Open screwdriver stop s to flush installation for one minute minimum 4A Run water for a sufficient time so the hot and cold water supplies are as hot and cold as possible 4B Place a thermometer in a plastic container an...

Страница 7: ...tion is complete and the faucet is ready to use The cover should be secured at this time STEP 6 TEST FOR OPERATION Test for operation If OK then close lid Use caution not to damage wires or components on electronic driver board Route wires through notches openings in the box See Fig 18 Secure lid using screws If faucet leaks from spout outlet SHUT OFF WATER SUPPLIES Check proper solenoid connectio...

Страница 8: ...e converter Refer to Fig 24 and Fig 25 for reference wiring diagrams Install the grounding kit assembly 061259A per the supplied instruction sheet for proper grounding with Conductive and Non Conductive sinks Turn on power supply for the transformer 5 quick beeps 3 times will be generated when power is first applied to the unit At this stage step back at least 3 feet from the controller and spout ...

Страница 9: ... change in capacitance the ability to store an electrical charge is brought on by a 2nd conductor a human body entering the Proximity field As the human hand enters and leaves the vicinity of the electrical field around the spout the solenoid is opened and closed accordingly It is critical in the installation process that all electrical and mechanical connections be as tight and rigid as possible ...

Страница 10: ...f system Must be replaced with solenoid and washers Figure 28 STEP 3 CONNECT WATER SUPPLY Install sink and connect drainage to rough in See Figure 28 Polymer braided hose supplied must be connected to the spout Other connection tubes and fittings are supplied by the installer to connect to the 1 2 nominal sweat at the box outlet Connect water supply through to spout Assure supply lines are complet...

Страница 11: ...s The solenoid will stay open while hands are moving then close once hands are removed from the sensing zone CONDUCTIVE SINKS NON CONDUCTIVE SINKS Fig 33 Fig 32 Metal Sink Mounting Hardware or Bracket Control Box 1 Driver Board P3 GND 120VAC Ground Electrical Box Metal Box Ground Wiring Sink Ground Wiring Earth Ground Wiring Control Box 8 To Additional Sinks Driver Boards Vitreous China Sink Contr...

Страница 12: ...cer is for temporary use only for flushing of system Must be replaced with solenoid and washers Figure 35 STEP 4 FLUSH SYSTEM SET TEMPERATURE Remove coverplate from control box Open screwdriver stop s to flush installation for one minute minimum 4A Run water for a sufficient time so the hot and cold water supplies are as hot and cold as possible 4B Place a thermometer in a plastic container and ho...

Страница 13: ...LIBRATION After power is applied to the driver board it generates 5 quick beeps 3 times which prompts the installer to step away from the unit During the calibration process the water will turn ON for several seconds then proceed to shut off An additional 5 beeps indicates calibration is complete and the faucet is ready to use The cover should be secured at this time STEP 6 TEST FOR OPERATION Test...

Страница 14: ...to store an electrical charge is brought on by a 2nd conductor a human body entering the Proximity field As the human hand enters and leaves the vicinity of the electrical field around the spout the solenoid is opened and closed accordingly It is critical in the installation process that all electrical and mechanical connections be as tight and rigid as possible ensuring a smooth signal is carried...

Страница 15: ...seconds 2 0 2 5 3 0 minutes Metering Mode b Buzzer For Proximity the buzzer setting does not silence the controller and sensor status annunciations Buzzer options are ON and OFF the default setting is ON ON ON OFF M This feature changes the product into a metering faucet it will run the full set amount of time after the user s hands are first detected Note Auto Timer T is disabled when the feature...

Страница 16: ...nd water closets HARSH ABRASIVES or POLISH To clean simply wipe the surface with a damp cloth and blot dry with a soft cloth CARE INSTRUCTIONS Proximity sensing technology works by sensing changes in the electrical field Nearby conductive materials that are electrically charged or not properly electrically grounded may interfere with the desired function of the product If the controller is unable ...

Страница 17: ...oid are functioning Ensure inlet screen on solenoid is not plugged with debris Check the incoming water supply Turned on proper pressure and volume etc Check for a pressure lock between the mixing valve and the solenoid Turn off the water supply and undo the connection to the inlet of the solenoid this will eliminate any built up pressure Then activate sensor and test fire the solenoid If after ab...

Страница 18: ...is warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty is for commercial products only from Delta Faucet Company and Delta Faucet Canada a division of Masco Canada Limited and is void for any damage to this faucet due to misuse abuse neglect accident improper installation any use in violation of instructions furnished by Delta Fa...

Отзывы: