MAKING ADJUSTMENTS

The factory defaults for all settings are shown in the Quick Reference Chart below.  If these are acceptable, the driver board is ready for use.  If

 changes are required, follow the instructions to make adjustments.

DRIVER BOARD QUICK REFERENCE CHART

Function

Description

Factory

Default Setting

Function Settings

Sensor

Sensitivity

Auto Timer

(faucet shut-off)

Higher numbers represent a more sensitive configuration.  Higher

sensitivity will increase the distance at which the user is detected.

The sensitivity settings are on a 10 point scale (1 - 10).  Please

note that these setting values are relative values and do not

correspond to a particular distance.

Auto Timer is a safety mode in the event the sensor continually 

senses a target.  In this case, the faucet will stop after the pre-

determined time period expires.

Sensitivity setting

5

45 seconds

1 to 10

5, 7, 10, 12, 15, 30, 45, 60, 75, 90

seconds

2.0, 3.0, 4.0, 5.0, 6.0, 7.0, 8.0, 9.0,

9.9 minutes

Symbol

d

T

R

Rinse Cycle

This feature is meant to purge stagnant water from supply lines.

The faucet will turn on after the set amount of hours of inactivity

and run the set 

Rinse Time (r)

 (see below).

--

- (OFF), 6, 12, 18, 24, 30, 36,

42, 48 hours

r

Rinse Time

This feature is only active if a 

Rinse Cycle (R)

 time is chosen.  The

setting determines how long the faucet will turn on during the

Rinse Cycle (R).

10 seconds

(once enabled)

10, 20, 30, 40, 50, 60, 90 seconds

2.0, 2.5, 3.0 minutes

Metering Mode

b

Buzzer

For Proximity, the buzzer setting does not silence the controller

and sensor status annunciations.  Buzzer options are ON and

-(OFF), the default setting is ON.

ON

ON, - (OFF)

M

This feature changes the product into a metering faucet; it will run

the full set amount of time after the user’s hands are first detected.

Note: 

Auto Timer (T)

 is disabled when the feature is turned on.

--

-- (OFF), 7, 8, 9, 10, 11, 12, 13,

14, 15, 18, 24, 30, 40, 50, 60, 90

seconds

2.0, 2.5, 3.0, 3.5, 4.0 minutes

BATTERY STRENGTH INDICATOR

To check the battery strength:

 

Press and hold MODE (yellow pushbutton on left hand side).  After 5 seconds the battery strength will be displayed:

 

●  FUL  -  Healthy

 

●  MID  -  Average

 

●  Lo_  -  Low Average

 

●  bAd  -  Replace Batteries (buzzer will annunciate and LED will blink if activated - if these features are turned on)

Page 15

209989   Rev. B

w w w . s p e c s e l e c t . c o m

To adjust settings, press and hold MODE (yellow pushbutton on left

hand side) until the Function symbol appears.  Once in Adjustment

Mode, keep pressing MODE until desired Function is reached (see

Quick Reference Table).  To change Function Setting, press and

release TOGGLE (white pushbutton on right hand side) until desired

Function Setting is reached (see Quick Reference Table).

Note:

 Controller will leave Adjustment Mode after 5 seconds of

inactivity.

Function

Function

Setting

MODE

TOGGLE

FOR CONTROL BOXES #0, 1 & 8

If you have any questions about the installation of this product or need help troubleshooting this product, please call Delta Commercial Technical

Services at 

1-800-387-8277 

(Canada) or 

1-877-509-2680 

(U.S.A.)

.

Содержание 62 TP3 Series

Страница 1: ...xx8TR Description Battery Operated Surface Mount Box 0 Battery Operated Control Box 1 Trim Battery Operated Control Box 8 Trim Hard Wire Operated Surface Mount Box 0 Hard Wire Operated Control Box 1 Trim Hard Wire Operated Control Box 8 Trim Page 2 4 6 8 10 12 COVER 060073A Screws 4 pkg and driver bit for covers 060577A 12 Stainless Steel Cover TMV Repair Kits 061137A Adjustment Wrench 063164A Che...

Страница 2: ... in accordance with local plumbing and electrical codes FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION Fig 3 w w w s p e c s e l e c t c o m 621TPxxx0 Battery Operated Surface Mount Box 0 Mount faucet to sink using the provided components in the following order grey bottom spacer washer lock nut Fig 1 NOTE The black top spacer must be used at all times between the spout and countertop sink and the...

Страница 3: ...tance the ability to store an electrical charge is brought on by a 2nd conductor a human body entering the Proximity field As the human hand enters and leaves the vicinity of the electrical field around the spout the solenoid is opened and closed accordingly It is critical in the installation process that all electrical and mechanical connections be as tight and rigid as possible ensuring a smooth...

Страница 4: ... at the box outlet Connect water supply through to spout Assure supply lines are completely flushed and free of debris Install aerator Product supplied as shown by solid lines All items shown by dotted lines supplied by others Typical Installation Recessed Mount Box Flexible Sensor Cord Conduit Polymer Braided Hose 257mm 10 13 Control Box 305mm 12 Stainless Steel Cover Plate 102mm 4 355mm 14 max F...

Страница 5: ...round a conductor the spout and monitoring the change in capacitance that the conductor undergoes The change in capaci tance the ability to store an electrical charge is brought on by a 2nd conductor a human body entering the Proximity field As the human hand enters and leaves the vicinity of the electrical field around the spout the solenoid is opened and closed accordingly It is critical in the ...

Страница 6: ... spacer is for temporary use only for flushing of system Must be replaced with solenoid and washers Figure 13 STEP 4 FLUSH SYSTEM SET TEMPERATURE Remove coverplate from control box Open screwdriver stop s to flush installation for one minute minimum 4A Run water for a sufficient time so the hot and cold water supplies are as hot and cold as possible 4B Place a thermometer in a plastic container an...

Страница 7: ...tion is complete and the faucet is ready to use The cover should be secured at this time STEP 6 TEST FOR OPERATION Test for operation If OK then close lid Use caution not to damage wires or components on electronic driver board Route wires through notches openings in the box See Fig 18 Secure lid using screws If faucet leaks from spout outlet SHUT OFF WATER SUPPLIES Check proper solenoid connectio...

Страница 8: ...e converter Refer to Fig 24 and Fig 25 for reference wiring diagrams Install the grounding kit assembly 061259A per the supplied instruction sheet for proper grounding with Conductive and Non Conductive sinks Turn on power supply for the transformer 5 quick beeps 3 times will be generated when power is first applied to the unit At this stage step back at least 3 feet from the controller and spout ...

Страница 9: ... change in capacitance the ability to store an electrical charge is brought on by a 2nd conductor a human body entering the Proximity field As the human hand enters and leaves the vicinity of the electrical field around the spout the solenoid is opened and closed accordingly It is critical in the installation process that all electrical and mechanical connections be as tight and rigid as possible ...

Страница 10: ...f system Must be replaced with solenoid and washers Figure 28 STEP 3 CONNECT WATER SUPPLY Install sink and connect drainage to rough in See Figure 28 Polymer braided hose supplied must be connected to the spout Other connection tubes and fittings are supplied by the installer to connect to the 1 2 nominal sweat at the box outlet Connect water supply through to spout Assure supply lines are complet...

Страница 11: ...s The solenoid will stay open while hands are moving then close once hands are removed from the sensing zone CONDUCTIVE SINKS NON CONDUCTIVE SINKS Fig 33 Fig 32 Metal Sink Mounting Hardware or Bracket Control Box 1 Driver Board P3 GND 120VAC Ground Electrical Box Metal Box Ground Wiring Sink Ground Wiring Earth Ground Wiring Control Box 8 To Additional Sinks Driver Boards Vitreous China Sink Contr...

Страница 12: ...cer is for temporary use only for flushing of system Must be replaced with solenoid and washers Figure 35 STEP 4 FLUSH SYSTEM SET TEMPERATURE Remove coverplate from control box Open screwdriver stop s to flush installation for one minute minimum 4A Run water for a sufficient time so the hot and cold water supplies are as hot and cold as possible 4B Place a thermometer in a plastic container and ho...

Страница 13: ...LIBRATION After power is applied to the driver board it generates 5 quick beeps 3 times which prompts the installer to step away from the unit During the calibration process the water will turn ON for several seconds then proceed to shut off An additional 5 beeps indicates calibration is complete and the faucet is ready to use The cover should be secured at this time STEP 6 TEST FOR OPERATION Test...

Страница 14: ...to store an electrical charge is brought on by a 2nd conductor a human body entering the Proximity field As the human hand enters and leaves the vicinity of the electrical field around the spout the solenoid is opened and closed accordingly It is critical in the installation process that all electrical and mechanical connections be as tight and rigid as possible ensuring a smooth signal is carried...

Страница 15: ...seconds 2 0 2 5 3 0 minutes Metering Mode b Buzzer For Proximity the buzzer setting does not silence the controller and sensor status annunciations Buzzer options are ON and OFF the default setting is ON ON ON OFF M This feature changes the product into a metering faucet it will run the full set amount of time after the user s hands are first detected Note Auto Timer T is disabled when the feature...

Страница 16: ...nd water closets HARSH ABRASIVES or POLISH To clean simply wipe the surface with a damp cloth and blot dry with a soft cloth CARE INSTRUCTIONS Proximity sensing technology works by sensing changes in the electrical field Nearby conductive materials that are electrically charged or not properly electrically grounded may interfere with the desired function of the product If the controller is unable ...

Страница 17: ...oid are functioning Ensure inlet screen on solenoid is not plugged with debris Check the incoming water supply Turned on proper pressure and volume etc Check for a pressure lock between the mixing valve and the solenoid Turn off the water supply and undo the connection to the inlet of the solenoid this will eliminate any built up pressure Then activate sensor and test fire the solenoid If after ab...

Страница 18: ...is warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty is for commercial products only from Delta Faucet Company and Delta Faucet Canada a division of Masco Canada Limited and is void for any damage to this faucet due to misuse abuse neglect accident improper installation any use in violation of instructions furnished by Delta Fa...

Отзывы: