Check to ensure faucet was installed

according to the M&I sheet.

Test for operation.  If unit does not

operate:

Step 1

Note: See attached M&I, pages 1 to 15.

Verify spacers are in place; black spacer on top and grey spacer on the

bottom of the sink or counter.
Check to be sure power cable is properly secured in fitting.
Check to be sure batteries are fresh and properly installed.
Check two wires to solenoid to be sure they are connected correctly.
Check to be sure water supply is turned on.
Check to ensure sensor module is connected to the controller board.
Check to ensure sensor module is attached to spout shank.
Check to ensure polymer braided hoses are connected to both inlet and

outlet of the solenoid on surface mount box #0.
Confirm the spout and sensor clip do not contact any conductive

material, including conductive water lines, metallic sinks, structural

supports or other mounting hardware.

Faucet makes beeping noise.

Step 2

BATTERY POWERED  

Faucet beeps twice when turning off:

 indicates

batteries are low and need to be replaced (1500 cycles or 2 weeks left). 

Faucet beeps continuously when hands in front of spout and no

water.

  Faucet locked out because batteries are too low.

HARDWIRE  

Check voltage from converter and transformer.  It should

be approximately 6.4 volts DC coming from converter to the driver board.

  

Replace batteries.

Replace batteries.

Replace Hard Wire

converter 060683A or

061047A (BB), if

required.

The faucet stops working.  No water

flow.  Check the function of the solenoid.

Step 3

The solenoid should “click” when activated.

Clean as required.
Correct as required.

If there is a

clicking sound;

If no

clicking sound;

 

This indicates that both the sensor and the solenoid are functioning.
Ensure inlet screen on solenoid is not plugged with debris.
Check the incoming water supply. Turned on, proper pressure and

volume, etc.
Check for a pressure lock between the mixing valve and the solenoid.

Turn off the water supply and undo the connection to the inlet of the

solenoid, this will eliminate any built up pressure.

Then activate sensor and test fire the solenoid.
If after above there is no clicking sound;

Defective solenoid.

 

 

Replace 063127A or

060671A Solenoid.

 

If faucet does not activate, works

erratically or water turns on at random.

Step 4

If after completion of all above steps, the valve still does not function correctly; Call Technical Service for further assistance at 1-800-387-8277

(Canada) or 1-877-509-2680 (U.S.A.).

Step 5

Check for electrical interference.
Check for interference from other electrical devices within close

proximity to the spout or battery box.  Devices such as electrical power

or data wiring, transformers, etc.
If hardwired, confirm controller is properly grounded.
If installed on a metal sink, ensure sink and controller are both properly

grounded.
Confirm spout inlet is supplied by the polymer braided hose.

Call Technical Service

if any such conditions

found.  

 

TROUBLESHOOTING GUIDE

Faucet turns on and off constantly.

Faucet turns on, but shuts off immediately.

Ensure there is sufficient flow to the faucet (ensure inlet screen on

solenoid is not plugged with debris).
Check supply voltage.
Check to ensure batteries are fresh and of the correct type.
Check to ensure polymer braided hoses are connected to both inlet and

outlet of the solenoid on surface mount box #0.
Confirm batteries are secure and properly oriented in holder.
Ensure power connector from controller is securely attached to AC/DC

converter or battery holder.
Recalibrate by disconnecting the AC/DC converter or battery for 10

seconds, then reconnecting.  Allow unit to re-calibrate.

Install 4 “C” batteries.

Clean as required.

Содержание 62 TP3 Series

Страница 1: ...xx8TR Description Battery Operated Surface Mount Box 0 Battery Operated Control Box 1 Trim Battery Operated Control Box 8 Trim Hard Wire Operated Surface Mount Box 0 Hard Wire Operated Control Box 1 Trim Hard Wire Operated Control Box 8 Trim Page 2 4 6 8 10 12 COVER 060073A Screws 4 pkg and driver bit for covers 060577A 12 Stainless Steel Cover TMV Repair Kits 061137A Adjustment Wrench 063164A Che...

Страница 2: ... in accordance with local plumbing and electrical codes FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION Fig 3 w w w s p e c s e l e c t c o m 621TPxxx0 Battery Operated Surface Mount Box 0 Mount faucet to sink using the provided components in the following order grey bottom spacer washer lock nut Fig 1 NOTE The black top spacer must be used at all times between the spout and countertop sink and the...

Страница 3: ...tance the ability to store an electrical charge is brought on by a 2nd conductor a human body entering the Proximity field As the human hand enters and leaves the vicinity of the electrical field around the spout the solenoid is opened and closed accordingly It is critical in the installation process that all electrical and mechanical connections be as tight and rigid as possible ensuring a smooth...

Страница 4: ... at the box outlet Connect water supply through to spout Assure supply lines are completely flushed and free of debris Install aerator Product supplied as shown by solid lines All items shown by dotted lines supplied by others Typical Installation Recessed Mount Box Flexible Sensor Cord Conduit Polymer Braided Hose 257mm 10 13 Control Box 305mm 12 Stainless Steel Cover Plate 102mm 4 355mm 14 max F...

Страница 5: ...round a conductor the spout and monitoring the change in capacitance that the conductor undergoes The change in capaci tance the ability to store an electrical charge is brought on by a 2nd conductor a human body entering the Proximity field As the human hand enters and leaves the vicinity of the electrical field around the spout the solenoid is opened and closed accordingly It is critical in the ...

Страница 6: ... spacer is for temporary use only for flushing of system Must be replaced with solenoid and washers Figure 13 STEP 4 FLUSH SYSTEM SET TEMPERATURE Remove coverplate from control box Open screwdriver stop s to flush installation for one minute minimum 4A Run water for a sufficient time so the hot and cold water supplies are as hot and cold as possible 4B Place a thermometer in a plastic container an...

Страница 7: ...tion is complete and the faucet is ready to use The cover should be secured at this time STEP 6 TEST FOR OPERATION Test for operation If OK then close lid Use caution not to damage wires or components on electronic driver board Route wires through notches openings in the box See Fig 18 Secure lid using screws If faucet leaks from spout outlet SHUT OFF WATER SUPPLIES Check proper solenoid connectio...

Страница 8: ...e converter Refer to Fig 24 and Fig 25 for reference wiring diagrams Install the grounding kit assembly 061259A per the supplied instruction sheet for proper grounding with Conductive and Non Conductive sinks Turn on power supply for the transformer 5 quick beeps 3 times will be generated when power is first applied to the unit At this stage step back at least 3 feet from the controller and spout ...

Страница 9: ... change in capacitance the ability to store an electrical charge is brought on by a 2nd conductor a human body entering the Proximity field As the human hand enters and leaves the vicinity of the electrical field around the spout the solenoid is opened and closed accordingly It is critical in the installation process that all electrical and mechanical connections be as tight and rigid as possible ...

Страница 10: ...f system Must be replaced with solenoid and washers Figure 28 STEP 3 CONNECT WATER SUPPLY Install sink and connect drainage to rough in See Figure 28 Polymer braided hose supplied must be connected to the spout Other connection tubes and fittings are supplied by the installer to connect to the 1 2 nominal sweat at the box outlet Connect water supply through to spout Assure supply lines are complet...

Страница 11: ...s The solenoid will stay open while hands are moving then close once hands are removed from the sensing zone CONDUCTIVE SINKS NON CONDUCTIVE SINKS Fig 33 Fig 32 Metal Sink Mounting Hardware or Bracket Control Box 1 Driver Board P3 GND 120VAC Ground Electrical Box Metal Box Ground Wiring Sink Ground Wiring Earth Ground Wiring Control Box 8 To Additional Sinks Driver Boards Vitreous China Sink Contr...

Страница 12: ...cer is for temporary use only for flushing of system Must be replaced with solenoid and washers Figure 35 STEP 4 FLUSH SYSTEM SET TEMPERATURE Remove coverplate from control box Open screwdriver stop s to flush installation for one minute minimum 4A Run water for a sufficient time so the hot and cold water supplies are as hot and cold as possible 4B Place a thermometer in a plastic container and ho...

Страница 13: ...LIBRATION After power is applied to the driver board it generates 5 quick beeps 3 times which prompts the installer to step away from the unit During the calibration process the water will turn ON for several seconds then proceed to shut off An additional 5 beeps indicates calibration is complete and the faucet is ready to use The cover should be secured at this time STEP 6 TEST FOR OPERATION Test...

Страница 14: ...to store an electrical charge is brought on by a 2nd conductor a human body entering the Proximity field As the human hand enters and leaves the vicinity of the electrical field around the spout the solenoid is opened and closed accordingly It is critical in the installation process that all electrical and mechanical connections be as tight and rigid as possible ensuring a smooth signal is carried...

Страница 15: ...seconds 2 0 2 5 3 0 minutes Metering Mode b Buzzer For Proximity the buzzer setting does not silence the controller and sensor status annunciations Buzzer options are ON and OFF the default setting is ON ON ON OFF M This feature changes the product into a metering faucet it will run the full set amount of time after the user s hands are first detected Note Auto Timer T is disabled when the feature...

Страница 16: ...nd water closets HARSH ABRASIVES or POLISH To clean simply wipe the surface with a damp cloth and blot dry with a soft cloth CARE INSTRUCTIONS Proximity sensing technology works by sensing changes in the electrical field Nearby conductive materials that are electrically charged or not properly electrically grounded may interfere with the desired function of the product If the controller is unable ...

Страница 17: ...oid are functioning Ensure inlet screen on solenoid is not plugged with debris Check the incoming water supply Turned on proper pressure and volume etc Check for a pressure lock between the mixing valve and the solenoid Turn off the water supply and undo the connection to the inlet of the solenoid this will eliminate any built up pressure Then activate sensor and test fire the solenoid If after ab...

Страница 18: ...is warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty is for commercial products only from Delta Faucet Company and Delta Faucet Canada a division of Masco Canada Limited and is void for any damage to this faucet due to misuse abuse neglect accident improper installation any use in violation of instructions furnished by Delta Fa...

Отзывы: