Delta Water Engineering Escalda Скачать руководство пользователя страница 8

P0522 

         DELTA WATER ENGINEERING 

V01/2017/P8

 

3.7

 

Connect  the  brine  valve  (#5)  to  the  softener  by  means  of  the  Ø4mm 
flexible  tube.  Insert  the  tube  as  far  as  possible  (to  stop)  into  the  quick-

release couplings. Make sure not to squeeze the tube; avoid kinks. 

 

 
 

 
 

 

3.8

 

The  unit  can  be  installed  in  the  container  in  three  different  ways:  at  the 

back, to the left or to the right. The support at the bottom of the container 
must  be  placed  accordingly.  Please  refer  to  the  figures  on  the  following 

page. 

 

3.8.1

 

Connections at the back: 

 

The  arrow  on  the  support  in  the  container  must  be  pointing  to  the  back. 

Place the device in the container with the connections at the back, as shown 
below.  

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

Содержание Escalda

Страница 1: ...P0522 DELTA WATER ENGINEERING V01 2017 P1 D De el lt ta a W Wa at te er r E En ng gi in ne ee er ri in ng g...

Страница 2: ...IO ON N G GU UI ID DE E E ES SC CA AL LD DA A 1 Parts 1 BYPASS 7 WATER OUTLET 2 VALVE HOUSING 8 BLENDING REGULATOR 3 RESIN TANK 9 HARDNESS REGULATOR 4 CONTAINER FOR DEVICE AND SALT 10 TO BRINE VALVE 5...

Страница 3: ...st 1bar to ensure a good functioning of the softener If this pressure of at least 1bar can t be guaranteed a Pressure Guard is available at your Delta supplier The water should be free of sediment chl...

Страница 4: ...ons The Delta Bypass has a connection The direct connections on the water softener are available in and 1 Caution before installing the softener set the Bypass in bypass mode not in service 3 3 Connec...

Страница 5: ...arate instruction leaflet with detailed information has been added to the device 3 5 To connect the flexible drain pipe from the softener par 3 3 and from the overflow par 3 4 with a fixed drain pipe...

Страница 6: ...t container is higher than the connection on the D O D 3 5 3 If the part with the connections for the tubes is disconnected from the transparent part snap them back together Even if the two parts are...

Страница 7: ...with the round opening Check if the brine valve is installed properly Open the small cover by pressing it gently at both sides The brine valve has to be installed with the right side up and all the w...

Страница 8: ...be avoid kinks 3 8 The unit can be installed in the container in three different ways at the back to the left or to the right The support at the bottom of the container must be placed accordingly Plea...

Страница 9: ...P0522 DELTA WATER ENGINEERING V01 2017 P9 3 8 2 Connections to the left As in 3 8 1 3 8 3 Connections to the right As in 3 8 1...

Страница 10: ...settings of CaCO3 10 ppm CaCO3 1 fh 1 dh 1 78 fh Adjust the hardness regulator to the measured value This requires a hex key number 5 4 2 Blending regulator part number 8 on the illustration on page...

Страница 11: ...ou do not use a Bypass open the main valve slowly as described in 5 4 5 2 Fill salt bin with salt in the provided space Use only specific salt tablets that are suitable for softeners 5 3 Add water in...

Страница 12: ...iately the PRG will drop down a little you will be able to see and hear this R stands for refill refilling the container with water at the end of the regeneration stage To make sure the softener is in...

Страница 13: ...the container First the valve house cover make sure the connections fit in the large opening and the drain in the small opening Then place the front lid For future salt refills only the front lid has...

Страница 14: ...f the resin and damage the synthetic material Failure to comply with these regulations a failure of the device or accident claim will not be eligible for warranty and stops the product responsibility...

Страница 15: ...e valve and push the black 4mm tubing coming from the brine valve back in the press fitting on the valve The unit will now complete its regeneration After the suction zone marked will the letter B Bri...

Страница 16: ...dge about hydraulic softeners and domestic plumbing Proper working of the softener will be determined by proper installation An annual control of your Delta softener will guarantee optimal functioning...