background image

 

HD33[L]M.GSM

 

-   6   - 

V1.10

 

Atmospheric pressure

 

Sensor 

Piezoresistive 

Measuring range 

300…1100 hPa 

Resolution (of instrument) 

0.1 hPa 

Accuracy 

± 0.5 hPa (800...1100 hPa) @ T=25°C  

± 1 hPa (300...1100 hPa) @ T=0...50°C 

Stability 

1 hPa / year 

Temperature drift 

±3 hPa tra -20…+60 °C 

Solar radiation

 

Sensor 

Thermopile 

Measuring range 

0…2000 W/m

2

 

Resolution (of the instrument) 

1 W/m

2

 

Sensitivity 

Configurable in mV/(kW

 

m

-2

Calculated quantities 

Daily Wh/m

2

 (Wh = watt hour) 

For the other characteristics, please refer to the data sheet of the chosen pyranometer. 

Rainfall quantity

 

Sensor 

With contact output (configurable NC or NO in the data logger)  

Resolution (of the instrument) 

Configurable 0.1 – 0.2 – 0.5 mm/tipping 

Calculated quantities 

Rainfall rate in mm/h, rainfall quantity in the last day. 

The rainfall rate is calculated by referring the rainfall quantity in the 

last five minutes to an hourly value. 

For the other characteristics, please refer to the data sheet of the chosen rain gauge. 
A measurement compensation curve as a function of the rainfall rate can be configured. 

Wind speed – Characteristics of the HD54.3 cup anemometer 

Sensor 

Passive 3-cup anemometer 

Measuring range 

1…75 m/s 

Resolution (of the instrument) 

0.1 m/s 

Accuracy 

± 0.14 m/s @ 10 m/s installed on a flat terrain site 

Offset 

0.35 m/s 

Gain 

0.765 m s

-1

/Hz 

Distance constant 

(63% recovery) 

2.55 m @ 5 m/s / 2.56 m @ 10 m/s (ASTM D 5096-02) 

Calculated quantities 

Felt air temperature as a function of the wind speed: 

Wind Chill

 index 

(only if the logger measures also temperature). 

Wind gust

: maximum wind speed obtained from the 3 seconds 

averages of the measurements acquired once per second. 

Wind direction – Characteristics of the HD54.D vane 

Sensor 

continuous rotation potentiometric vane 

Measuring range 

0…359° 

Resolution (of the instrument) 

1° 

Accuracy 

< 1%  

Dead band 

4° typical, 8° max. 

Threshold 

1 m/s 

4…20 mA input 

Shunt resistance 

Internal (50 

Ω

Resolution 

12 bit 

Accuracy 

± 2 µA 

Содержание HD33[L]M.GSM

Страница 1: ...Operating manual GSM Data Logger HD33 L M GSM Keep for future reference www deltaohm com English Companies Brands of GHM...

Страница 2: ...TECHNICAL CHARACTERISTICS 5 4 MEASURING PROBES 7 5 SIM CARD 8 6 INSTALLATION 9 7 POWER SUPPLY 9 8 USB CONNECTION 10 9 HD35AP S SOFTWARE 10 10 SMS COMMANDS 11 11 GPRS TCP IP CONNECTION 13 12 STORAGE OF...

Страница 3: ...o GSM GPRS transmission the user will not have to remove the data logger from its position or reach the place where the data logger is installed to download the data measured with the PC the instrumen...

Страница 4: ...or LED red blinking indicates that the instrument is powered blinks green to signal the GSM activity 4 Custom LCD display The cyclic automatic scrolling of the measurements can be set with the HD35AP...

Страница 5: ...Weight 1 kg approx including shield and fixing clamping Housing Dimensions 122 x 120 x 56 mm excluding external antenna Material Polycarbonate PC Protection degree IP 67 with protective cap on the US...

Страница 6: ...tes to an hourly value For the other characteristics please refer to the data sheet of the chosen rain gauge A measurement compensation curve as a function of the rainfall rate can be configured Wind...

Страница 7: ...lable Solar radiation The pyranometers LP PYRA 02 LP PYRA 03 LP PYRA 10 LP SILICON PYRA 04 etc with mV output signal can be connected Wind speed and direction For the measurement of wind speed and dir...

Страница 8: ...t the SIM tray back in place and push the metal block in the direction of the arrow LOCK 6 Close again the housing by fixing the 4 front screws Through the HD35AP S software set the necessary informat...

Страница 9: ...th direct voltage from 7 to 30 Vdc and can be powered by mains through the power supply unit HD32MT SWD or by a solar panel through the power supply unit HD32WSF S12 that includes a 12 Vdc 7 2 Ah batt...

Страница 10: ...it is not powered by the PC USB port When the data logger is not connected to the PC replace the mini USB connector protective cap to ensure the watertight integrity of the instrument 9 HD35AP S SOFTW...

Страница 11: ...of measurement data via FTP FTP OFF Deactivates the periodic download of measurement data via FTP FTP PERIOD period index Set the transmission interval via FTP where period index 0 15 min 1 30 min 2 1...

Страница 12: ...date where YYYY year MM month DD day HH hour MM minutes SS seconds HTTP DL INTERVAL YYYY MM DD HH MM SS YYYY MM DD HH MM SS Uploads on the HTTP server all data between the specified dates where YYYY y...

Страница 13: ...he Modem Router 4 Disconnect the data logger from the USB port 5 In the HD35AP S software select Tools Type of connection select the TCP server option and set the number of the port opened in the Mode...

Страница 14: ...safety technical conditions The regular functioning and operational safety of these instruments can be ensured only if all normal safety measures as well as the specific measures described in this man...

Страница 15: ...K sensor temperature probe Measuring range 40 105 C Probe stem AISI 304 14 mm length 150 mm Cable length 2 5 or 10 m standard 4 pole M12 female connector HD9007A 1 12 ring protection against solar rad...

Страница 16: ...ion 0 2 mm 0 1 or 0 5 mm on request with order Normally closed output contact Power supply 12 Vdc or 24 Vdc 10 absorbed power 50 W HD2016 Weighing rain gauge area 400 cm2 3000 cc collecting reservoir...

Страница 17: ...itions 40 60 C 0 100 RH Rod mounting Dimensions 210 x 120 mm HD54 9K Transverse mast kit including transverse mast 40 mm and L 1500 mm two extension bars 40 mm and accessories ACCESSORIES HD35AP CFR21...

Страница 18: ...n be fixed on a flat base with screws or to the ground with pegs Foldable legs for the transport HD2005 20 1 Tripod kit with adjustable legs for installing environmental sensors pyranometers temperatu...

Страница 19: ......

Страница 20: ...third parties is excluded from the guarantee The instrument shall be returned FREE OF SHIPMENT CHARGES to your dealer The jurisdiction of Padua applies in any dispute The electrical and electronic eq...

Страница 21: ...e result of the constant development of the product This may produce some differences between the information written in this manual and the instrument you have purchased We cannot completely exclude...

Страница 22: ...GHM GROUP Delta OHM Delta Ohm S r l a socio unico Via Marconi 5 35030 Caselle di Selvazzano Padova ITALY Phone 39 049 8977150 Fax 39 049 635596 www deltaohm com info deltaohm com V1 10 10 10 2018...

Отзывы: