Command 

Description 

SMS-DEVICE-ALARM-REPORT 

Transmits via SMS a report of the measurements selected for SMS alarms 

SMS-DEVICE-REPORT 

Transmits via SMS a report of the measurements of the device 

SMS-HELP 

Transmits an SMS containing the list of all SMS commands 

TCP-SERVER-ON 

Activates a TCP connection with AP acting as a TCP server 

TCP-SERVER-OFF 

Deactivates the TCP connection with the device acting as a TCP server 

TCP-CLIENT-ON 

Activates a TCP connection with the device acting as a TCP client 

TCP-CLIENT-OFF 

Deactivate the TCP connection with the device acting as a TCP client 

TCP-SERVER-ADDRESS=”

server 

address

” 

Specifies the server address for TCP connection when the device acts as TCP 

client. The server-address string can be a domain or a IP address 

TCP-SERVER-PORT=

port

 

number 

 

Specifies the number of the TCP port used by the remote server to accept 

connections with the device when the device acts as TCP client 

TCP-LISTEN-PORT=

port number 

 

Specifies the number of the TCP listening port used by the device when the 

device acts as TCP server 

HTTP-ON 

Activates the periodic upload of measurement data on the HTTP server 

HTTP-OFF 

Deactivates the periodic upload of measurement data on the HTTP server 

HTTP-PERIOD=

 period index

 

Set the transmission interval via HTTP, where 

period index

-1

Real time, 0

15 min, 1

30 min, 2

1 hour, 3

2 hours, 4

4 hours, 

5

8 hours, 6

12 hours, 7

24 hours, 8

2 days, 9

4 days, 10

1 week 

HTTP-DL-START 

Activates immediate data upload on the HTTP server starting from the last 

measurement transmitted 

HTTP-DL-FROM=

YYYY/MM/DD 

HH:MM:SS

 

Uploads data on the HTTP server starting from the specified date, where 

YYYY: year, MM: month, DD: day, HH: hour, MM: minutes, SS: seconds 

HTTP-DL-INTERVAL=

YYYY/MM/DD 

HH:MM:SS - YYYY/MM/DD HH:MM:SS

 

Uploads on the HTTP server all data between the specified dates, where 

YYYY: year, MM: month, DD: day, HH: hour, MM: minutes, SS: seconds 

ADD-PHONE=”

phone

 

number

” 

Adds a phone number to the list of numbers considered for SMS alarms 

CANC-PHONE 

Delete my phone number and don’t consider it any more for SMS alarms. 

The primary phone number cannot be deleted 

ERASE-PHONE=

phone

 

number index

 

Deletes the phone number with specified index. This command is accepted 

only by the primary phone number 

MEASURE-INTERVAL=

interval index

 

Set the measuring interval, where 

interval index

: 0->1 s, 1->2 s, 2->5 s, 

3->10 s, 4->15 s, 5->30 s, 6->1 min, 7->2 min, 8->5 min, 9->10 min, 
10->15 min, 11->30 min, 12->1 hour 

LOG-INTERVAL=

 interval index

 

Set the logging interval, where 

interval index

: 0->1 s, 1->2 s, 2->5 s, 

3->10 s, 4->15 s, 5->30 s, 6->1 min, 7->2 min, 8->5 min, 9->10 min, 

10->15 min, 11->30 min, 12->1 hour 

Up to 16 commands can be written in the same text message, separated by spaces or commas. 
For safety, commands are executed only if they are coming from the cell numbers set in the 

HD35AP-S software and if the SMS text starts with a user-defined key word. The key word is 

set through the HD35AP-S software, going to the menu " 

GSM options 

" at the item " 

SMS 

recipients 

" and setting the field " 

SMS keyword 

" (see chapter " 

GSM settings 

" of the software 

online help). 

Example

: supposing you entered the string “

>>>

” in the 

SMS keyword

 field and you wish to 

activate periodic download via e-mail of the measured data with an interval of 1 hour, you will 

have to send the following text message: 

>>> EMAIL-ON EMAIL-PERIOD=2 

With the commands EMAIL-HELP, FTP-HELP and SMS-HELP you can ask the base unit to send 
respectively by e-mail, to an FTP address and through SMS the complete list of the available 

SMS commands. 

Содержание HD33[L]M.GSM

Страница 1: ...Operating manual GSM Data Logger HD33 L M GSM Keep for future reference www deltaohm com English Companies Brands of GHM...

Страница 2: ...TECHNICAL CHARACTERISTICS 5 4 MEASURING PROBES 7 5 SIM CARD 8 6 INSTALLATION 9 7 POWER SUPPLY 9 8 USB CONNECTION 10 9 HD35AP S SOFTWARE 10 10 SMS COMMANDS 11 11 GPRS TCP IP CONNECTION 13 12 STORAGE OF...

Страница 3: ...o GSM GPRS transmission the user will not have to remove the data logger from its position or reach the place where the data logger is installed to download the data measured with the PC the instrumen...

Страница 4: ...or LED red blinking indicates that the instrument is powered blinks green to signal the GSM activity 4 Custom LCD display The cyclic automatic scrolling of the measurements can be set with the HD35AP...

Страница 5: ...Weight 1 kg approx including shield and fixing clamping Housing Dimensions 122 x 120 x 56 mm excluding external antenna Material Polycarbonate PC Protection degree IP 67 with protective cap on the US...

Страница 6: ...tes to an hourly value For the other characteristics please refer to the data sheet of the chosen rain gauge A measurement compensation curve as a function of the rainfall rate can be configured Wind...

Страница 7: ...lable Solar radiation The pyranometers LP PYRA 02 LP PYRA 03 LP PYRA 10 LP SILICON PYRA 04 etc with mV output signal can be connected Wind speed and direction For the measurement of wind speed and dir...

Страница 8: ...t the SIM tray back in place and push the metal block in the direction of the arrow LOCK 6 Close again the housing by fixing the 4 front screws Through the HD35AP S software set the necessary informat...

Страница 9: ...th direct voltage from 7 to 30 Vdc and can be powered by mains through the power supply unit HD32MT SWD or by a solar panel through the power supply unit HD32WSF S12 that includes a 12 Vdc 7 2 Ah batt...

Страница 10: ...it is not powered by the PC USB port When the data logger is not connected to the PC replace the mini USB connector protective cap to ensure the watertight integrity of the instrument 9 HD35AP S SOFTW...

Страница 11: ...of measurement data via FTP FTP OFF Deactivates the periodic download of measurement data via FTP FTP PERIOD period index Set the transmission interval via FTP where period index 0 15 min 1 30 min 2 1...

Страница 12: ...date where YYYY year MM month DD day HH hour MM minutes SS seconds HTTP DL INTERVAL YYYY MM DD HH MM SS YYYY MM DD HH MM SS Uploads on the HTTP server all data between the specified dates where YYYY y...

Страница 13: ...he Modem Router 4 Disconnect the data logger from the USB port 5 In the HD35AP S software select Tools Type of connection select the TCP server option and set the number of the port opened in the Mode...

Страница 14: ...safety technical conditions The regular functioning and operational safety of these instruments can be ensured only if all normal safety measures as well as the specific measures described in this man...

Страница 15: ...K sensor temperature probe Measuring range 40 105 C Probe stem AISI 304 14 mm length 150 mm Cable length 2 5 or 10 m standard 4 pole M12 female connector HD9007A 1 12 ring protection against solar rad...

Страница 16: ...ion 0 2 mm 0 1 or 0 5 mm on request with order Normally closed output contact Power supply 12 Vdc or 24 Vdc 10 absorbed power 50 W HD2016 Weighing rain gauge area 400 cm2 3000 cc collecting reservoir...

Страница 17: ...itions 40 60 C 0 100 RH Rod mounting Dimensions 210 x 120 mm HD54 9K Transverse mast kit including transverse mast 40 mm and L 1500 mm two extension bars 40 mm and accessories ACCESSORIES HD35AP CFR21...

Страница 18: ...n be fixed on a flat base with screws or to the ground with pegs Foldable legs for the transport HD2005 20 1 Tripod kit with adjustable legs for installing environmental sensors pyranometers temperatu...

Страница 19: ......

Страница 20: ...third parties is excluded from the guarantee The instrument shall be returned FREE OF SHIPMENT CHARGES to your dealer The jurisdiction of Padua applies in any dispute The electrical and electronic eq...

Страница 21: ...e result of the constant development of the product This may produce some differences between the information written in this manual and the instrument you have purchased We cannot completely exclude...

Страница 22: ...GHM GROUP Delta OHM Delta Ohm S r l a socio unico Via Marconi 5 35030 Caselle di Selvazzano Padova ITALY Phone 39 049 8977150 Fax 39 049 635596 www deltaohm com info deltaohm com V1 10 10 10 2018...

Отзывы: