8. Testing your installation
8.1 Test under operating conditions
Test your installation under actual operating conditions by triggering an alarm
with each of your detectors.
During this test, you must take the “exit timer” into account to achieve effective
surveillance (up to 90 seconds).
Test the motion detectors
The motion detector stores each passage in the detection
zone for 90 seconds (whether or not the system is on).
For the test, activate the system from a point where you will not be detected.
Wait for 2 minutes before entering the detection zone
(irrespective of the exit timer).
Whenever the system is activated or deactivated, the alarm control unit sends a
series of beeps indicating that an event (motion detection in this case) has
occurred. You can view this on a touch screen keypad.
To clear the event:
Press and hold the remote control's OFF button for 5 seconds.
The control unit emits beeps when pressed, then a series of beeps after 5 sec-
onds.
The LED changes to green on the remote control.
Release.
The event is cleared.
The event can also be "cleared" through the Info menu of a touch screen key-
pad.
• If the detector is in delayed triggering mode, the control unit
will only set off the alarm after a programmed time (up to 45
seconds).
During this time, it will emit warning beeps.
• If the alarm control unit does not sound, take another look at
the installation or association of the detector.
• If the installation is equipped with a transmitter, check that the
detection triggers a call cycle to the programmed numbers.
OFF
ON
2'
Stop the alarm
Beep,
Beep
Alarm control unit
sets off the siren
Enter the detection
zone
Wait for 2 minutes
Activate
your system
outside of the
detection zone