![Delta Computer Systems VMC 186/40 Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/delta-computer-systems/vmc-186-40/vmc-186-40_manual_2475109034.webp)
VMC 186/40 Motion Hardware Information
34
Number of
Recirculations
Maximum
Linear
Transducer
Length
Typical
Measurement
Time
@ 30"
Maximum
Usable
Transducer
Resolution
1 130"
273us
.002"
2 65"
546us
.001"
4 32"
1092us
.0005"
Transducer Delay per mm (358.27ns typical)
Counts per mm =
* Recirculations
18ns per clock (55.5 Mhz clk)
65535
Maximum Linear Transducer Length =
Counts per mm
Longest Measurement Time = Distance on Transducer in mm * Delay * Recirculation
1
mm
Maximum Resolution =
Counts per mm
Number of
Recirculations
Maximum
Linear
Transducer
Length
Typical
Measurement
Time @ 750mm
Maximum
Usable
Transducer
Resolution
1 3293mm
269us
.0502mm
2 1647mm
537us
.0251mm
4 823mm
1075us
.0126mm
CAUTION: The longest measurement time should never exceed 1000 microseconds. The data used by the
VMC 186/40 must be available within its millisecond control loop for precise control. If more than 1000
microseconds is required to obtain a position measurement, the controller will slow down to a two millisecond
control loop. If a two millisecond control loop is required, a slight bump will occur in the motion of the axis at
the transition point.
JUMPER P8-P11
(Default Four Recirculations)
Jumper P8 for axis 1
Jumper P9 for axis 2
Jumper P11 for axis 3
Jumper P10 for axis 4
1
2
4
P8
1
2
4
P9
1
4
P10
1
2
4
P11
2
1
3
4
2