VMC 186/40 Motion Hardware Information
32
Hardware Configuration Information
Supported VME Bus Address Modifiers
The following address modifiers are supported:
29H
Short non-privileged access (16 bit) (check with Delta before using)
2DH
Short supervisory (check with Delta before using)
39H (GE 90-70)
Standard non-privileged data access (24 bit)
3D
Standard supervisory access
Note: If these address modifiers are not used or a long word accesses is requested, a bus error will be generated.
R1-R4
P4
P5
P6
P7
P8
P9
P10 P11
P13
P20
P15
P16
P17
P18
VMC 186/40
P12
P14
RF
Module Jumpers and Removable Resistors
RF
Resistor fuses for transducer power (page 41)
R1-R4 Sockets for 100
Ω
resistors, when installed, convert current outputs to
±
10 volts (page 38)
P4-P7 Select transducer interrogation pulse polarity (page 32)
P8-P11 Select number of transducer recirculations (page 33)
P12
Enable a VMC 186/40 module reset if the module fails to toggle a 60 ms timer (page 36)
P13
Enable on-board interrupt if the module fails to toggle a 13 ms timer (page 36)
P14
Permit a VME bus reset to reset the VMC 186/40 (page 36)
P15
Board VME bus address selection for A09 through A15 (page 35)
P16
Board VME bus address selection for A16 through A23 (page 35)
P17
Selects IRQ interrupt line to use on the VME bus (page 37)
P18
Selects IRQ number to acknowledge from the VME bus (page 37)
P20
Provided for firmware development (page 37)