For example; if the operator wanted to produce 10% of full extend drive:
(assumes current
Null Drive
value of 2048)
Requested Speed
2047 (maximum valve drive)
Requested Position
204 (10% of full positive drive)
Command
79
('O')
Results in a
Drive
value of 2252 (null + 204)
Another example; to retract at 50% of full drive (assumes current
Null Drive
value of 2048)
Requested Speed
2047 (maximum valve drive)
Requested Position
-
1024 (50% of full negative drive, 64511 decimal)
Command
79 ('O')
Results in a drive value of 1024 (null + (-1024))
Prior to August of 1992, the Override command would put the axis into a mode in which only counts and
servo drive would be updated. After this date,
Actual Position
will update, providing scaled position
information.
CAUTION: -
Use of this command provides no safety limitation, or conditions.
S' - Save Null (53H)(83)
The Save command saves the current value of the null so that it may be recalled
later by a Restore command.
'R' - Restore Null (52H)(82)
The Restore command restores the last saved value of null. This value will
be 2048 if no previous Save or
New Null