21
TABLE FOR THE CHOICE OF THE INJECTORS
Natural gas
ULPG
Test Point Pressure
[kPa]
1.0
2.75
BURNER
Injector Orifice Dia.
[mm]
Gas Consumption
[MJ/h]
Injector Orifice Dia.
[mm]
Gas Consumption
[MJ/h]
Auxiliary (A)
0.85
3.60
0.53
3.60
Semi-rapid (SR)
1.12
6.30
0.70
6.30
Rapid (R)
1.45
10.30
0.91
10.80
Triple ring (TR)
1.60
12.70
0.95
11.90
Oven
1.90
17.00
1.13
17.00
LUBRICATION OF THE GAS TAPS
If a gas valve becomes stiff, it is necessary to dismantle it carefully and clean it with
petroleum spirit.
Specialist high temperature resistant grease should be used to lubricate the valve before
replacing.
The operations must be carried out by an authorised person/service agent.