18
3.
Affix to the rear of the appliance, in proximity of the gas inlet connections, the warning
label (supplied with the conversion kit) stating that the cooker has been converted for
use with ULPG / Natural gas.
IMPORTANT
■
If the cooker is suitable for use with Natural gas and must be converted for use with
ULPG, before connecting to the gas mains remove the appliance gas regulator and
replace with test point adaptor (see figs. 12a - 12b).
■
If the cooker is suitable for use with ULPG and must be converted for use with Natural
gas, before connecting to the gas mains remove the appliance test point adaptor and
replace with gas regulator (see figs. 12a - 12b).
NOTE:
Gas regulator and test point adaptor are supplied with the appliance (packed with
conversion kit).
MINIMUM BURNER SETTING ADJUSTMENT
1. Cooktop burners
Check whether the flame spreads to all burner ports when the burner is lit with the gas
tap set to the minimum position. If some ports do not light, increase the minimum gas
rate setting.
Check whether the burner remains lit even when the gas tap is turned quickly from
the maximum to the minimum position. If the burner does not remain lit, increase the
minimum gas rate setting.
The procedure for adjusting the minimum gas rate setting is described below.
■
Turn on the burner.
■
Turn the tap to the MINIMUM position.
■
Take off the knob.
■
Using a small flat screwdriver turn the screw “
F
” to the correct regulation (fig. 18).
Normally for ULPG, the regulation screw is tightened up.
2. Oven burner
In the minimum position the flame must have a length of about 4 mm and must remain
lit even with a brusque passage from the maximum position to that of minimum.
The flame adjustment is done in the following way:
■
Turn on the oven burner by setting the thermostat knob on maximum position.
■
Remove the knob and unscrew the by-pass screw “
G
” (fig. 19) about three times
by passing a small flat screwdriver (Ø 3 mm blade, 100 mm length) through the
panel opening.
■
Re-mount the knob and let the oven heat up for about 10 minutes, then bring the
knob to position “
1
” (minimum) to operate the thermostat by-pass.
■
After having removed the knob again and being very careful not to turn the
thermostat shaft, slowly screw the by-pass screws “
G
” (fig. 19) until you obtain a
flame of 3-4 mm in height.
Normally for ULPG, the regulation screw is tightened up.
Содержание DEF905GEG
Страница 2: ...2...
Страница 19: ...19 F Figure 18 G Figure 19...
Страница 41: ...41 S F C T A B T S Figure 45c Figure 45d Figure 45e Figure 45a Figure 45b...
Страница 50: ...50...
Страница 51: ...51...