NOTE:
Some steps do not apply if you are replacing a different switch or non-Dell EMC switch.
NOTE:
ESD damage can occur when components are mishandled. Always wear an ESD-preventive wrist or heel ground
strap when handling the switch and accessories. After you remove the original packaging, place the switch and components
on an anti-static surface.
1. Back up the switch configuration to your back-up computer or laptop TFTP server.
OS10# copy config://startup.xml config://<
backup file name
>
2. Disconnect the power source.
3. Label and remove all cables.
4. Remove the switch from the rack.
Simultaneously, press in the two side-release bars on the switch and slide the switch forward.
If you are using the fan trays or PSUs in the replacement switch, remove them from the switch.
5. Unpack the new switch.
6. Install the new switch in your rack or cabinet.
For detailed installation instructions, see
.
If you are using the fan trays or PSUs from the removed switch, reinsert them in the replacement switch.
7. Connect all the cables.
8. Power on the switch.
For more information, see
.
9. Establish a connection to the switch CLI.
10. Confirm that the software version of the replacement switch is the same as the previously installed switch.
show version
If the software versions do not match, upgrade the replacement switch software using the procedure that is included with
the firmware download.
11. Copy the backed-up switch configuration to the new switch.
copy tftp://hostip/filepath running-config
S5448F-ON switch installation
29
Содержание S5448F-ON
Страница 1: ...Dell EMC PowerSwitch S5448F ON Installation Guide March 2022 March 2022 Rev A01 ...
Страница 24: ...OR 9 5 mm square hole rack OR EIA 7 1 mm 279 in round hole rack 24 S5448F ON switch installation ...
Страница 49: ...64 bytes from xx xx x xx seq 1 ttl 62 time 0 577 ms C Before you install an operating system 49 ...