![Dell PowerEdge C8220 Скачать руководство пользователя страница 55](http://html.mh-extra.com/html/dell/poweredge-c8220/poweredge-c8220_hardware-owners-manual_85390055.webp)
Using the System Setup Program
55
• Serial Port Mode: 115200 8,n,1
• Flow Control: None
• Redirection After BIOS POST: Always
• Terminal Type: ANSI
See "Remote Access Configuration" on page 95 for details. Make sure the
last four options syncs with the host and client.
7
In the Server screen, select
BMC LAN Configuration
and press <Enter>.
8
In the BMC LAN Configuration screen, verify the following settings:
• BMC LAN Port Configuration: Shared-NIC
• BMC NIC IP Source: DHCP or Static (Use DHCP if your network
servers are using automatic assignment of IP addresses)
• IP Address: 192.168.001.003
• Subnet Mask: 255.255.255.000
• Gateway Address: 000.000.000.000
See "Set BMC LAN Configuration" on page 93 for details. Make sure the
host and client are on the same network
9
Press <Esc> to return to the System Setup screen. Press <Esc> again,
and a message prompts you to save the changes.
Serial Port Connection List
Signal Type
Setup Option
OS
Setting
Output
Remote
Access
Serial Port
Number
Serial Port
Address
Serial Console
Redirection
Enabled
COM1
3F8h/2F8h
ttyS0
Serial Port
Enabled
COM1
2F8h/3F8h
ttyS1
BMC Serial
Over LAN
Enabled
COM2 as SOL 3F8h/2F8h
ttyS1
Management
Port
Enabled
COM2 as SOL 2F8h/3F8h
ttyS0
Содержание PowerEdge C8220
Страница 1: ...Dell PowerEdge C8220 Hardware Owner s Manual Regulatory Model B05B Regulatory Type B05B001 ...
Страница 138: ...138 Using the System Setup Program ...
Страница 208: ...208 Installing System Components ...
Страница 224: ...224 Troubleshooting ...
Страница 236: ...236 Jumpers and Connectors Expansion Card Riser Connector Figure 5 7 Expansion Card Riser Connector 1 PCIe x16 slot 5 1 ...
Страница 242: ...242 Getting Help ...