![Dell PowerEdge C8220 Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/dell/poweredge-c8220/poweredge-c8220_hardware-owners-manual_85390037.webp)
About Your System
37
SB Error
Message: “Critical Interrupt Sensor, Correctable, MCU Parity Error”
Table 1-6. SB Error
Byte
Field
Value
Description
1
NetFunLun
10h
2
Platform Event Command
02h
3
Generator ID
01h
Generated by BIOS
4
Event Message Format
Version
04h
Event Message Format Revision.
04h for this specification
5
Sensor Type
13h
Critical Interrupt
6
Sensor Number
77h
SB Sensor ID (depend on
platform)
7
Event Direction Event Type
6Fh
Bit 7: 0 = Assert Event
Bit 6: 0 = Event Type Code
8
Event Data1
AXh
07h: Correctable
08h: Uncorrectable
9
Event Data2
XXh
Bit 7:5Reserved Local error bit
number (4 ~ 0)
00000b: HT Periodic CRC Error
00001b: HT Protocol Error
00010b: HT Flow-Control Buffer
Overflow
00011b: HT Response Error
00100b: HT Per-Packet CRC Error
00101b: HT Retry Counter Error
00111b: MCU Parity Error
10
Event Data3
FFh
FFh: Not Present