About the System
53
PCIe Error
Message: “Critical Interrupt Sensor, PCI PERR, Device#, Function#,
Bus#”
Table 1-3. PCIe Error
Byte
Field
Value
Description
1
NetFunLun
10h
2
Platform Event Command
02h
3
Generator ID
01h
Generated by BIOS
4
Event Message Format
Version
04h
Event Message Format Revision.
04h for this specification
5
Sensor Type
13h
Critical Interrupt
6
Sensor Number
73h
PCI Sensor ID (depend on
platform)
7
Event Direction Event Type
6Fh
Bit 7: 0 = Assert Event
Bit 6: 0 = Event Type Code
8
Event Data1
AXh
04h: PCI PERR
05h: PCI SERR
07h: Bus Correctable Error
08h: Bus Uncorrectable Error
0Ah: Bus Fatal Error
9
Event Data2
XXh
Bit 7:3Device Number
Bit 2:0Function Number
10
Event Data3
XXh
Bit 7:0 Bus Number