42
About the System
POST Error Codes
Collecting System Event Log for Investigation
Whenever possible, the system BIOS will output the current boot progress
codes on the video screen. Progress codes are 32-bit quantities plus optional
data. The 32-bit numbers include class, subclass, and operation information.
The class and subclass fields point to the type of hardware that is being
initialized. The operation field represents the specific initialization activity.
Based on the data bit availability to display progress codes, a progress code
can be customized to fit the data width. The higher the data bit, the higher
the granularity of information that can be sent on the progress port. The
progress codes may be reported by the system BIOS or option ROMs.
The Response section in the following table may be divided into 3 types:
• Warning or Not an error – The message is displayed on the screen. An error
record is logged to the SEL. The system will continue booting with a
degraded state. The user may want to replace the erroneous unit.
• Pause – The message is displayed on the screen, an error is logged to the
SEL, and user input is required to continue. The user can take immediate
corrective action or choose to continue booting.
• Halt – The message is displayed on the screen, an error is logged to the
SEL, and the system cannot boot unless the error is resolved. The user
needs to replace the faulty part and restart the system.
Error
Code
Error Message
Response Error Cause
Corrective Actions
0010h Local
Console
Resource
Conflict
Pause
Video device
initialization
failed
See "Troubleshooting the
Video Subsystem" on
page 252.
If the problem persists, see
"Getting Help" on page 289.
0011h Local
Console
Controller Error
Pause
Video device
initialization
failed
See "Troubleshooting the
Video Subsystem" on
page 252.
If the problem persists, see
"Getting Help" on page 289.
Содержание PowerEdge C8000
Страница 1: ...Dell PowerEdge C8000 Hardware Owner s Manual Regulatory Model B10S Regulatory Type B10S001 ...
Страница 41: ...About the System 41 Figure 1 24 Service Tag Location for C8000XD Storage Sled ...
Страница 160: ...160 Using the System Setup Program MIB Tree Diagram for FCB ...
Страница 170: ...170 Using the System Setup Program MIB Tree Diagram for PMC ...
Страница 185: ...Using the System Setup Program 185 ...
Страница 186: ...186 Using the System Setup Program ...
Страница 220: ...220 Installing System Components ...
Страница 250: ...250 Rack Mount Configuration ...
Страница 274: ...274 Troubleshooting ...
Страница 288: ...288 Jumpers and Connectors ...
Страница 290: ...290 Getting Help ...