3-4
Dell PowerEdge 6350 Systems Installation and Troubleshooting Guide
Embedded server
management
error
Embedded server
management is
not present
Embedded server man-
agement memory may
be temporarily corrupted
Shut down the system to clear
the memory, and then restart
the system. If the problem
persists, see Chapter 12,
“Getting Help,” for instruc-
tions on obtaining technical
assistance.
Gate A20
failure
Faulty keyboard control-
ler (defective system
board)
Replace the system board.
See Chapter 12, “Getting
Help,” for instructions on
obtaining technical assistance.
General failure
Operating system cor-
rupted or not installed
properly
Reinstall the operating
system.
Hard disk
controller
failure
Hard disk drive
read failure
Hard disk
failure
Incorrect configuration
settings in System Setup
program, improperly
connected hard-disk
drive, faulty hard-disk
drive controller
subsystem (defective
system board), or loose
power cable
Check the hard-disk drive
configuration settings in the
System Setup program. See
Chapter 4, “Using the System
Setup Program,” in the sys-
tem
User’s Guide for instruc-
tions. Reinstall the hard-disk
drive. Check the interface
cable and power cable connec-
tions to the backplane board.
See Chapter 10, “Installing
Hard-Disk Drives.”
Invalid
configuration
information -
please run
SETUP program
Incorrect ISA_CLR
jumper configuration,
incorrect configuration
settings in System Setup
program, or faulty bat-
tery
Remove the plug from the
ISA_CLR jumper. See Appen-
dix B, “Jumpers, Switches,
and Connectors,” for instruc-
tions. Check the System Setup
configuration settings. See
Chapter 4, “Using the System
Setup Program,” in the system
User’s Guide for instructions.
Replace the battery. See
Chapter 8, “Installing System
Board Options.”
Invalid CPU
speed detected
- check jumpers
Incorrect microproces-
sor jumper configuration
Check the microprocessor
speed jumper. See Appendix B,
“Jumpers, Switches, and
Connectors.”
7DEOH 6\VWHP 0HVVDJHV FRQWLQXHG
0HVVDJH
&DXVH
&RUUHFWLYH $FWLRQ
NOTE: For the full name of an abbreviation or acronym used in this table, see the abbreviation and
acronym list that precedes the Index.
Содержание PowerEdge 6350
Страница 1: ... ZZZ GHOO FRP HOO 3RZHU GJH 6 VWHPV 167 7 21 1 7528 6 227 1 8 ...
Страница 20: ...1 2 Dell PowerEdge 6350 Systems Installation and Troubleshooting Guide ...
Страница 50: ...4 4 Dell PowerEdge 6350 Systems Installation and Troubleshooting Guide ...
Страница 84: ...6 8 Dell PowerEdge 6350 Systems Installation and Troubleshooting Guide ...
Страница 128: ...8 18 Dell PowerEdge 6350 Systems Installation and Troubleshooting Guide ...
Страница 136: ...9 8 Dell PowerEdge 6350 Systems Installation and Troubleshooting Guide ...
Страница 182: ...A 8 Dell PowerEdge 6350 Systems Installation and Troubleshooting Guide ...
Страница 185: ...Jumpers Switches and Connectors B 3 LJXUH 6 VWHP RDUG XPSHUV jumpered unjumpered ...
Страница 192: ...B 10 Dell PowerEdge 6350 Systems Installation and Troubleshooting Guide ...