PowerConnect B-MLXe Hardware Installation Guide
73
53-1002111-01
Verifying proper operation
2
1. Make sure the cable is securely connected to your PC or terminal and the console port or
Ethernet port.
2. Check the settings in your terminal emulation program. In addition to the session settings
listed in
“Attaching a PC or terminal to the console port or Ethernet port”
on page 68, make
sure the terminal emulation session is running on the same serial port you attached to the
console port.
When you see this prompt (MLXe-16#), you are connected to the system and can display module
status using the CLI. Enter the show module command at any CLI level.
Syntax: show module
The Status column shows the module status. The management module status can be one of the
following:
•
ACTIVE – The module is currently the active management module.
•
STANDBY – The module is currently the standby management module.
•
COMING UP – The module is coming up as the standby module. This status occurs if the
standby management module becomes the active module during a switchover.
The switch fabric module status can be one of the following:
•
ACTIVE – The module is up and running.
•
BAD – The management module cannot initialize the switch fabric module.
An interface module status can be one of the following:
•
CARD_STATE_INIT – The system detects the module but the module is not up and running yet.
•
CARD_STATE_BOOT – The module is booting.
•
CARD_STATE_INTERACTIVE – The module is booting from interactive mode.
•
CARD_STATE_LP_SYNC – The software images are synchronized between the management
module and interface module.
•
CARD_STATE_SYNC – The system is currently synchronizing the software image between the
management module and interface module.
•
CARD_STATE_SOFTWARE_LOADED – The module has loaded the software image.
•
CARD_STATE_POWER_OFF – The module does not have power.
•
CARD_STATE_UP – The module is operating normally.
MLXe-16# show module
Module Status Ports Starting MAC
M1 (upper): NetIron Mgmt Module Active
M2 (lower):
F0: NetIron Switch Fabric Module Active
S1:
S2:
S3:
S4: NetIron 4-Port 10Gig Module CARD_STATE_UP 4 000c.db80.0000
S5: NetIron 4-Port 10Gig Module CARD_STATE_UP 4 000c.db80.0000
S6: NetIron 4-Port 10Gig Module CARD_STATE_UP 4 000c.db80.0000
S7:
S8:
Содержание PowerConnect B - MLXe 16
Страница 1: ...53 1002111 01 02 November 2010 PowerConnect B MLXe Hardware Installation Guide ...
Страница 34: ...22 PowerConnect B MLXe Hardware Installation Guide 53 1002111 01 Supported software features 1 ...
Страница 136: ...124 PowerConnect B MLXe Hardware Installation Guide 53 1002111 01 Removing MAC address entries 5 ...
Страница 194: ...182 PowerConnect B MLXe Hardware Installation Guide 53 1002111 01 Power cords 8 ...
Страница 198: ...186 PowerConnect B MLXe Hardware Installation Guide 53 1002111 01 Russia A ...
Страница 212: ...200 PowerConnect B MLXe Hardware Installation Guide 53 1002111 01 Dangers B ...