PowerConnect B-MLXe Hardware Installation Guide
53-1002111-01
Managing the cooling system
5
Fan Speed Med: 57 - 70
Fan Speed Med-Hi: 67 - 80
Fan Speed Hi: 77 - 85
state = 0 (FAN_STATE_LOW)
max_ts_shut_off_count = 1
shut_off_count = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
=== Thermal Sensor Control Block (THERMAL_SENSOR_TEST_RULE_MP_CPU) ===
Fan Speed Low: -1 - 60
Fan Speed Med: 57 - 70
Fan Speed Med-Hi: 67 - 80
Fan Speed Hi: 77 - 95
state = 1 (FAN_STATE_MED)
max_ts_shut_off_count = 1
shut_off_count = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
=== Thermal Sensor Control Block (THERMAL_SENSOR_TEST_RULE_STANDBY_MP_CPU) ===
Fan Speed Low: -1 - 60
Fan Speed Med: 57 - 70
Fan Speed Med-Hi: 67 - 80
Fan Speed Hi: 77 - 95
state = 0 (FAN_STATE_LOW)
max_ts_shut_off_count = 1
shut_off_count = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Syntax: show fan-threshold
The output displays the following information.
Changing the temperature polling interval
By default, the router reads the temperature sensor on each module every 60 seconds. To change
the polling interval, enter the temp-poll-period command at the global CONFIG level of the CLI.
PowerConnect(config)# temp-poll-period 120
Syntax: temp-poll-period
<seconds>
For the
<seconds>
parameter, you can specify a value from 30 – 120. You can also specify 0,
which disables the system from polling the temperature sensor on each module.
TABLE 22
Temperature threshold information for modules and fan speeds
This field...
Displays...
Thermal Sensor Control Block
(THERMAL_SENSOR_TEST_RULE_<
module>)
The temperature threshold information for the various modules. The
<module> parameter indicates the following:
•
MP – The active management module
•
STANDBY_MP – The standby management module
•
SNM – The switch fabric module
•
LP – An interface module
Fan Speed Low or Med or Med-Hi or
Hi
The current setting of the low and high temperature thresholds for the low,
medium, medium-high, and high fan speeds.
NOTE: The low fan speed for each module does not have a default low
temperature threshold value, nor can you configure this value. The
“-1” value that appears in the Fan Speed Low field for each module
is a Dell internal value only.
State = 0 (FAN_STATE_LOW)
For Dell internal use only.
max_ts_shut_off_count
For Dell internal use only.
shut_off_count = 0 0 0 0 0 0 0 0
For Dell internal use only.
Содержание PowerConnect B - MLXe 16
Страница 1: ...53 1002111 01 02 November 2010 PowerConnect B MLXe Hardware Installation Guide ...
Страница 34: ...22 PowerConnect B MLXe Hardware Installation Guide 53 1002111 01 Supported software features 1 ...
Страница 136: ...124 PowerConnect B MLXe Hardware Installation Guide 53 1002111 01 Removing MAC address entries 5 ...
Страница 194: ...182 PowerConnect B MLXe Hardware Installation Guide 53 1002111 01 Power cords 8 ...
Страница 198: ...186 PowerConnect B MLXe Hardware Installation Guide 53 1002111 01 Russia A ...
Страница 212: ...200 PowerConnect B MLXe Hardware Installation Guide 53 1002111 01 Dangers B ...