![Dell PowerConnect B-DCX-4S Backbone Скачать руководство пользователя страница 62](http://html.mh-extra.com/html/dell/powerconnect-b-dcx-4s-backbone/powerconnect-b-dcx-4s-backbone_hardware-reference-manual_79255062.webp)
48
PowerConnect B-DCX-4S Backbone Hardware Reference Manual
53-1001808-01
RRP: Port, application, and encryption blades
5
FIGURE 21
RRP: Port, application, or encryption blade (FC8-48 port blade shown)
Replacing a blade
ATTENTION
Follow ESD precautions (
“ESD precautions”
).
NOTE
An FA4-18i application blade and the PowerConnect B-DCX-4S must have the same version of
firmware. To upgrade firmware versions, refer to the
Fabric OS Administrator’s Guide
.
1. Orient the blade so that the ports are at the front of the chassis and the flat side of the blade is
on the bottom.
2. Perform the appropriate following action based on the type of blade:
•
For FC8-16, FC8-32, FC8-48 port blades, FX8-24, FCOE10-24 application blades, and
FS8-18 encryption blade: Adjust the ejectors to the open position, align the flat side of the
blade inside the left and right rail guides in the slot, and slide the blade into the slot until it
is firmly seated.
•
For FC10-6 port blade, and FA4-18, and FR4-18i application blades: Open the ejectors to
approximately 45 degrees, align the flat side of the port blade inside the left and right rail
guides in the slot, and slide the blade into the slot until it is firmly seated.
Содержание PowerConnect B-DCX-4S Backbone
Страница 8: ...viii PowerConnect B DCX 4S Backbone Hardware Reference Manual 53 1001808 01 ...
Страница 24: ...10 PowerConnect B DCX 4S Backbone Hardware Reference Manual 53 1001808 01 Network manageability 1 ...
Страница 113: ...PowerConnect B DCX 4S Backbone Hardware Reference Manual 99 53 1001808 01 Environmental regulation compliance A ...
Страница 114: ...100 PowerConnect B DCX 4S Backbone Hardware Reference Manual 53 1001808 01 Environmental regulation compliance A ...
Страница 134: ...120 PowerConnect B DCX4S Backbone Hardware Reference Manual 53 1001808 01 ...